CVE-2026-13336: CWE-78 Improper neutralization of special elements used in an OS command ('OS command injection') in Schneider Electric NetBotz 5 - 750/755

0
High
VulnerabilityCVE-2026-13336cvecve-2026-13336cwe-78
Published: 09/01/2026 (09/01/2026, 13:27:07 UTC)
Source: CVE Database V5
Vendor/Project: Schneider Electric
Product: NetBotz 5 - 750/755

Description

CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause execution of Linux Operating system commands when a system back up is restored that has been maliciously modified.

CVSS v4.0

Score 7.3high

Attack Vector
Adjacent Network
Attack Complexity
Low
Attack Requirements
Present
Privileges Required
High
User Interaction
None
Vuln. Confidentiality
High
Vuln. Integrity
High
Vuln. Availability
High
Subsq. Confidentiality
None
Subsq. Integrity
None
Subsq. Availability
None
CVSS:4.0/AV:A/AC:L/AT:P/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N

Affected software

Schneider Electric

NetBotz 5 - 750/755

AI-Powered Analysis

Machine-generated threat intelligence

AILast updated: 09/07/2026, 14:38:40 UTC

Technical Analysis

This vulnerability (CWE-78) in Schneider Electric NetBotz 5 - 750/755 involves improper neutralization of special elements used in OS commands, leading to OS command injection. Specifically, when a system backup that has been maliciously altered is restored, it could cause execution of arbitrary Linux OS commands. The CVSS 4.0 score is 7.3 (high), with attack vector being adjacent network, low attack complexity, privileged required, no user interaction, and high impact on confidentiality, integrity, and availability. No patch or official fix information is currently available.

Potential Impact

Successful exploitation could allow an attacker with high privileges to execute arbitrary Linux OS commands on the affected device by restoring a maliciously modified system backup. This could compromise system confidentiality, integrity, and availability.

Mitigation Recommendations

Patch status is not yet confirmed — check the vendor advisory for current remediation guidance. Until an official fix is available, restrict access to backup restoration functionality to trusted administrators only and validate backups before restoration.

Pro Console: star threats, build custom feeds, automate alerts via Slack, email & webhooks.Upgrade to Pro

Technical Details

Data Version
5.2
Assigner Short Name
schneider
Date Reserved
2026-06-25T13:48:08.423Z
Cvss Version
4.0
State
PUBLISHED

Threat ID: 6a96d527acd9273b49c2e05a

Added to database: 09/01/2026, 13:37:43 UTC

Last enriched: 09/07/2026, 14:38:40 UTC

Last updated: 10/16/2026, 18:48:18 UTC

Views: 107

Community Reviews

0 reviews

Crowdsource mitigation strategies, share intel context, and vote on the most helpful responses. Sign in to add your voice and help keep defenders ahead.

Sort by
Loading community insights…

Want to contribute mitigation steps or threat intel context? Sign in or create an account to join the community discussion.

Actions

PRO

Updates to AI analysis require Pro Console access. Upgrade inside Console → Billing.

Please log in to the Console to use AI analysis features.

Need more coverage?

Upgrade to Pro Console for AI refresh and higher limits.

For incident response and remediation, OffSeq services can help resolve threats faster.

Latest Threats

Breach by OffSeqOFFSEQFRIENDS — 25% OFF

Check if your credentials are on the dark web

Instant breach scanning across billions of leaked records. Free tier available.

Scan now
OffSeq TrainingCredly Certified

Lead Pen Test Professional

Technical5-day eLearningPECB Accredited
View courses