Skip to main content
EPSS 0.2%top 93%

CVE-2026-13337: CWE-564 SQL injection: hibernate in Schneider Electric NetBotz 5 - 750/755

0
Medium
VulnerabilityCVE-2026-13337cvecve-2026-13337cwe-564
Published: 09/01/2026 (09/01/2026, 13:29:06 UTC)
Source: CVE Database V5
Vendor/Project: Schneider Electric
Product: NetBotz 5 - 750/755

Description

CWE-564: SQL Injection: Hibernate vulnerability exists that could allow the injection of a malicious HQL query in the NetBotz database when a malicious user is logged into the NetBotz via the web-service interface or webui.

CVSS v4.0

Score 5.1medium

Attack Vector
Adjacent Network
Attack Complexity
Low
Attack Requirements
None
Privileges Required
Low
User Interaction
None
Vuln. Confidentiality
Low
Vuln. Integrity
Low
Vuln. Availability
None
Subsq. Confidentiality
None
Subsq. Integrity
None
Subsq. Availability
None
CVSS:4.0/AV:A/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:N/SC:N/SI:N/SA:N

Affected software

Schneider Electric

NetBotz 5 - 750/755

AI-Powered Analysis

Machine-generated threat intelligence

AILast updated: 09/07/2026, 14:38:44 UTC

Technical Analysis

This vulnerability is a CWE-564 SQL injection in the Hibernate layer of Schneider Electric NetBotz 5 - 750/755 devices. It allows an authenticated user with low privileges to inject malicious HQL queries through the web-service interface or web UI, potentially compromising the integrity of the NetBotz database. The CVSS 4.0 base score is 5.1, reflecting medium severity with attack vector as adjacent network and low privileges required. No known exploits are reported in the wild, and no vendor remediation or patch information is provided at this time.

Potential Impact

An authenticated user with low privileges can inject malicious HQL queries into the NetBotz database, potentially leading to unauthorized data manipulation or corruption within the device's database. The impact is limited by the requirement for user login and the adjacent network attack vector, reducing the risk of remote exploitation without access.

Mitigation Recommendations

Patch status is not yet confirmed — check the vendor advisory for current remediation guidance. Until a fix is available, restrict access to the NetBotz web-service interface and web UI to trusted users only, and monitor for suspicious activity from authenticated users. Follow Schneider Electric's official advisories for updates.

Pro Console: star threats, build custom feeds, automate alerts via Slack, email & webhooks.Upgrade to Pro

Technical Details

Data Version
5.2
Assigner Short Name
schneider
Date Reserved
2026-06-25T13:48:11.990Z
Cvss Version
4.0
State
PUBLISHED

Threat ID: 6a96d527acd9273b49c2e05d

Added to database: 09/01/2026, 13:37:43 UTC

Last enriched: 09/07/2026, 14:38:44 UTC

Last updated: 10/17/2026, 18:48:17 UTC

Views: 104

Community Reviews

0 reviews

Crowdsource mitigation strategies, share intel context, and vote on the most helpful responses. Sign in to add your voice and help keep defenders ahead.

Sort by
Loading community insights…

Want to contribute mitigation steps or threat intel context? Sign in or create an account to join the community discussion.

Actions

PRO

Updates to AI analysis require Pro Console access. Upgrade inside Console → Billing.

Please log in to the Console to use AI analysis features.

Need more coverage?

Upgrade to Pro Console for AI refresh and higher limits.

For incident response and remediation, OffSeq services can help resolve threats faster.

Latest Threats

Breach by OffSeqOFFSEQFRIENDS — 25% OFF

Check if your credentials are on the dark web

Instant breach scanning across billions of leaked records. Free tier available.

Scan now
OffSeq TrainingCredly Certified

Lead Pen Test Professional

Technical5-day eLearningPECB Accredited
View courses