Skip to main content
VulnerabilityPublished

CVE-2026-15469: TP-Link Systems Deco XE75 v3 / XE5300 v3.6/ WE10800 v3.6 · Use of Hard-coded Cryptographic Key

Affects TP-Link Systems Deco XE75 v3 / XE5300 v3.6/ WE10800 v3.6Source CVE Database V5

0
Compare

Not known to be exploited · CVSS 7.7 High : upgrade to 1.5.0 Build 20260603 soon.

Data as of 21 Nov 2026, 17:35 UTC

CVSS 4.0 base score
7.7High
How severe the flaw is on the 0–10 CVSS scale.
EPSS
0.4% chance of exploitation in 30 days – higher than 36% of CVEsExploit Prediction Scoring System: the likelihood attackers will use this flaw soon.
Patch
Available – fixed in 1.5.0 Build 20260603
CVSS:4.0/AV:A/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:L/SI:L/SA:L

Exploitation evidence

  1. Disclosed: evidence found.

    CVE published 24 Aug 2026

  2. Detectable: no evidence on record.

    No public nuclei template indexed

  3. Weaponized: evidence found.

    Public exploit code: GitHub proofs of concept

  4. Exploited in the wild: no evidence on record.

    Not in CISA KEV and no source reports exploitation

  5. Observed by OffSeq Mirage: no evidence on record.

    No attack traffic recorded by OffSeq Mirage sensors

A missing step is not evidence of safety. Sources: cve.org (opens in a new tab), GitHub proofs of concept, the Metasploit, Exploit-DB and nuclei-templates index as of 21 Nov 2026.

What to do

Upgrade TP-Link Systems Deco XE75 v3 / XE5300 v3.6/ WE10800 v3.6 to 1.5.0 Build 20260603.

Affected software

ProductAffectedFixed in
TP-Link Systems Inc.Deco XE75 v3 / XE5300 v3.6/ WE10800 v3.6Affected
  • =0
Fixed in
  • 1.5.0 Build 20260603

AI-suggested

If you cannot patch yet, restrict local network access to trusted users and monitor for unauthorized mesh node activity.

Description

The use of hard-coded cryptographic key vulnerability has been identified in the mesh functionality of Deco XE75 v3, XE5300 v3.6 and WE10800 v3.6. A shared RSA-512 mesh group private key is present in the affected firmware and is used by the mesh protocol for node authentication. An attacker who obtains the firmware image and has local network access may be able to authenticate as a mesh node without possessing a device-specific credential. Successful exploitation may allow an unauthenticated adjacent attacker to impersonate a trusted mesh node and bypass mesh node authentication, which may permit unauthorized changes to device or mesh configuration, affecting confidentiality, integrity and availability.