CVE-2026-15579: CWE-787: Out-of-bounds Write in Moxa TN-4500B Series
An out-of-bounds write vulnerability exists in some of the Ethernet switches because of improper validation of the username field length during Web login processing. This may allow a remote attacker to submit a specially crafted overly long input, triggering a buffer overflow that can cause the authentication process to crash and result in a Denial of Service (DoS) attack.
AI Analysis
Technical Summary
This vulnerability (CVE-2026-15579) involves an out-of-bounds write (CWE-787) in the Moxa TN-4500B Series Ethernet switches. The root cause is insufficient validation of the username field length during the web login process, which allows a remote unauthenticated attacker to send a specially crafted long username input. This triggers a buffer overflow that crashes the authentication mechanism, causing a denial of service. The affected versions are >=1.0 and <=2.0. The CVSS 4.0 vector indicates network attack vector, low attack complexity, no privileges or user interaction required, with high impact on availability. No vendor patch or mitigation details are provided in the input.
Potential Impact
Successful exploitation results in denial of service by crashing the authentication process of the affected Ethernet switches. This disrupts normal device operation and network availability. There is no indication of code execution or data breach from the provided information. The vulnerability can be triggered remotely without authentication.
Mitigation Recommendations
Patch status is not yet confirmed — check the vendor advisory for current remediation guidance. Until an official fix is available, consider restricting access to the web login interface to trusted networks or IP addresses to reduce exposure. Monitor for unusual login attempts with abnormally long usernames as a potential indicator of exploitation attempts.
CVE-2026-15579: CWE-787: Out-of-bounds Write in Moxa TN-4500B Series
Description
An out-of-bounds write vulnerability exists in some of the Ethernet switches because of improper validation of the username field length during Web login processing. This may allow a remote attacker to submit a specially crafted overly long input, triggering a buffer overflow that can cause the authentication process to crash and result in a Denial of Service (DoS) attack.
CVSS v4.0
Score 8.8high
Affected software
Moxa
TN-4500B Series
Weaknesses
AI-Powered Analysis
Machine-generated threat intelligence
Technical Analysis
This vulnerability (CVE-2026-15579) involves an out-of-bounds write (CWE-787) in the Moxa TN-4500B Series Ethernet switches. The root cause is insufficient validation of the username field length during the web login process, which allows a remote unauthenticated attacker to send a specially crafted long username input. This triggers a buffer overflow that crashes the authentication mechanism, causing a denial of service. The affected versions are >=1.0 and <=2.0. The CVSS 4.0 vector indicates network attack vector, low attack complexity, no privileges or user interaction required, with high impact on availability. No vendor patch or mitigation details are provided in the input.
Potential Impact
Successful exploitation results in denial of service by crashing the authentication process of the affected Ethernet switches. This disrupts normal device operation and network availability. There is no indication of code execution or data breach from the provided information. The vulnerability can be triggered remotely without authentication.
Mitigation Recommendations
Patch status is not yet confirmed — check the vendor advisory for current remediation guidance. Until an official fix is available, consider restricting access to the web login interface to trusted networks or IP addresses to reduce exposure. Monitor for unusual login attempts with abnormally long usernames as a potential indicator of exploitation attempts.
Technical Details
- Data Version
- 5.2
- Assigner Short Name
- Moxa
- Date Reserved
- 2026-07-13T09:51:45.547Z
- Cvss Version
- 4.0
- State
- PUBLISHED
Threat ID: 6aad08a155bf5e2cf5d65f45
Added to database: 09/18/2026, 09:47:13 UTC
Last enriched: 09/18/2026, 10:01:46 UTC
Last updated: 09/18/2026, 23:56:15 UTC
Views: 11
Community Reviews
0 reviewsCrowdsource mitigation strategies, share intel context, and vote on the most helpful responses. Sign in to add your voice and help keep defenders ahead.
Want to contribute mitigation steps or threat intel context? Sign in or create an account to join the community discussion.
Actions
Updates to AI analysis require Pro Console access. Upgrade inside Console → Billing.
External Links
Need more coverage?
Upgrade to Pro Console for AI refresh and higher limits.
For incident response and remediation, OffSeq services can help resolve threats faster.
Latest Threats
Check if your credentials are on the dark web
Instant breach scanning across billions of leaked records. Free tier available.