Skip to main content
Press slash or control plus K to focus the search. Use the arrow keys to navigate results and press enter to open a threat.
Reconnecting to live updates…

CVE-2026-22891: CWE-122: Heap-based Buffer Overflow in The Biosig Project libbiosig

0
Critical
VulnerabilityCVE-2026-22891cvecve-2026-22891cwe-122
Published: Tue Mar 03 2026 (03/03/2026, 14:32:16 UTC)
Source: CVE Database V5
Vendor/Project: The Biosig Project
Product: libbiosig

Description

A heap-based buffer overflow vulnerability exists in the Intan CLP parsing functionality of The Biosig Project libbiosig 3.9.2 and Master Branch (db9a9a63). A specially crafted Intan CLP file can lead to arbitrary code execution. An attacker can provide a malicious file to trigger this vulnerability.

AI-Powered Analysis

AILast updated: 03/03/2026, 15:02:49 UTC

Technical Analysis

The Biosig Project's libbiosig library, specifically versions 3.9.2 and the Master Branch (db9a9a63), contains a heap-based buffer overflow vulnerability identified as CVE-2026-22891. This vulnerability resides in the Intan CLP file parsing component, where improper handling of input data leads to a buffer overflow on the heap. An attacker can exploit this by supplying a specially crafted Intan CLP file, which when parsed, causes memory corruption enabling arbitrary code execution. The flaw does not require any privileges or user interaction, and can be triggered remotely if the application processes untrusted Intan CLP files. The vulnerability is classified under CWE-122, indicating a classic heap-based buffer overflow. The CVSS v3.1 base score is 9.8, reflecting its critical nature with attack vector network (AV:N), low attack complexity (AC:L), no privileges required (PR:N), no user interaction (UI:N), and full impact on confidentiality, integrity, and availability (C:H/I:H/A:H). No patches or fixes are currently linked, and no exploits have been reported in the wild yet. This vulnerability poses a significant risk to any system or application utilizing libbiosig for biomedical signal processing, especially those that ingest Intan CLP files from untrusted sources.

Potential Impact

The impact of CVE-2026-22891 is severe for organizations worldwide that rely on libbiosig for processing biomedical signals, particularly those handling Intan CLP files. Successful exploitation allows remote attackers to execute arbitrary code, potentially leading to full system compromise. This can result in unauthorized data access, manipulation or deletion of sensitive biomedical data, disruption of critical healthcare or research operations, and the introduction of persistent malware. Given the criticality and ease of exploitation, attackers could leverage this vulnerability to pivot within networks, steal intellectual property, or sabotage medical research environments. The absence of required privileges or user interaction broadens the attack surface, increasing the likelihood of exploitation in automated or unattended processing scenarios. The vulnerability could also undermine trust in biomedical data integrity and availability, impacting patient care and scientific outcomes.

Mitigation Recommendations

To mitigate CVE-2026-22891, organizations should first monitor for and apply any official patches or updates released by The Biosig Project as soon as they become available. In the absence of patches, immediate risk reduction can be achieved by restricting or validating all Intan CLP files before processing, ensuring they originate from trusted sources only. Implement input validation and sandboxing techniques to isolate the parsing process, limiting the potential damage of exploitation. Employ runtime protections such as Address Space Layout Randomization (ASLR), Data Execution Prevention (DEP), and heap protection mechanisms to reduce exploitation success. Additionally, consider disabling or removing libbiosig components that handle Intan CLP files if not essential. Network-level controls to block or monitor suspicious file transfers and the use of intrusion detection systems tuned for anomalous behavior in biomedical processing environments can further reduce risk. Finally, maintain robust incident response plans to quickly address any suspected exploitation.

Need more detailed analysis?Upgrade to Pro Console

Technical Details

Data Version
5.2
Assigner Short Name
talos
Date Reserved
2026-01-28T12:55:08.823Z
Cvss Version
3.1
State
PUBLISHED

Threat ID: 69a6f4b6d1a09e29cb4db072

Added to database: 3/3/2026, 2:48:22 PM

Last enriched: 3/3/2026, 3:02:49 PM

Last updated: 3/3/2026, 9:01:58 PM

Views: 8

Community Reviews

0 reviews

Crowdsource mitigation strategies, share intel context, and vote on the most helpful responses. Sign in to add your voice and help keep defenders ahead.

Sort by
Loading community insights…

Want to contribute mitigation steps or threat intel context? Sign in or create an account to join the community discussion.

Actions

PRO

Updates to AI analysis require Pro Console access. Upgrade inside Console → Billing.

Please log in to the Console to use AI analysis features.

Need more coverage?

Upgrade to Pro Console in Console -> Billing for AI refresh and higher limits.

For incident response and remediation, OffSeq services can help resolve threats faster.

Latest Threats

Breach by OffSeqOFFSEQFRIENDS — 25% OFF

Check if your credentials are on the dark web

Instant breach scanning across billions of leaked records. Free tier available.

Scan now
OffSeq TrainingCredly Certified

Lead Pen Test Professional

Technical5-day eLearningPECB Accredited
View courses