Skip to main content
Press slash or control plus K to focus the search. Use the arrow keys to navigate results and press enter to open a threat.
Reconnecting to live updates…

CVE-2026-24502: CWE-427: Uncontrolled Search Path Element in Dell Dell Command | Intel vPro Out of Band

0
High
VulnerabilityCVE-2026-24502cvecve-2026-24502cwe-427
Published: Tue Mar 03 2026 (03/03/2026, 20:43:18 UTC)
Source: CVE Database V5
Vendor/Project: Dell
Product: Dell Command | Intel vPro Out of Band

Description

Dell Command | Intel vPro Out of Band, versions prior to 4.7.0, contain an Uncontrolled Search Path Element vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Elevation of privileges.

AI-Powered Analysis

AILast updated: 03/03/2026, 21:17:34 UTC

Technical Analysis

CVE-2026-24502 is a vulnerability classified under CWE-427 (Uncontrolled Search Path Element) affecting Dell Command | Intel vPro Out of Band software versions prior to 4.7.0. This vulnerability occurs because the software improperly manages the search path for executable files or libraries, allowing an attacker with low-level local access to influence which binaries or libraries are loaded. By placing a malicious file in a location that is searched before the legitimate one, the attacker can cause the software to execute arbitrary code with elevated privileges. The vulnerability does not require user interaction or additional authentication, making it easier to exploit once local access is obtained. The CVSS v3.1 score of 8.8 reflects the high impact on confidentiality, integrity, and availability, as successful exploitation could lead to full system compromise. Although no public exploits are known at this time, the flaw poses a significant risk in enterprise environments where Dell Command | Intel vPro Out of Band is used for remote management and system control. The vulnerability highlights the importance of secure path handling in privileged software components.

Potential Impact

The impact of CVE-2026-24502 is substantial for organizations relying on Dell Command | Intel vPro Out of Band for remote management and system provisioning. An attacker with local access can escalate privileges, potentially gaining administrative control over affected systems. This can lead to unauthorized disclosure of sensitive information, modification or destruction of data, and disruption of system availability. In managed enterprise environments, such privilege escalation could facilitate lateral movement, persistence, and deployment of further malware or ransomware. The vulnerability undermines the security of remote management infrastructure, which is critical for IT operations, especially in large organizations and data centers. The absence of required user interaction and the low complexity of exploitation increase the likelihood of successful attacks once local access is achieved. Although no exploits are currently known in the wild, the high CVSS score and the strategic importance of affected systems warrant immediate mitigation efforts.

Mitigation Recommendations

Organizations should implement the following specific mitigations: 1) Monitor Dell's official channels closely for the release of version 4.7.0 or later that addresses this vulnerability and apply patches promptly. 2) Restrict local access to systems running Dell Command | Intel vPro Out of Band to trusted personnel only, employing strict access controls and auditing. 3) Use application whitelisting and integrity verification tools to detect unauthorized changes to executable paths or binaries. 4) Employ endpoint detection and response (EDR) solutions to monitor for suspicious activity indicative of privilege escalation attempts. 5) Harden system configurations by minimizing the number of users with local access and disabling unnecessary services that could be leveraged to gain local entry. 6) Conduct regular security training to raise awareness about the risks of local access exploitation. 7) Review and secure environment variables and system PATH settings to prevent unauthorized path manipulation. These targeted steps go beyond generic advice by focusing on controlling local access and monitoring path integrity specific to this vulnerability.

Need more detailed analysis?Upgrade to Pro Console

Technical Details

Data Version
5.2
Assigner Short Name
dell
Date Reserved
2026-01-23T06:07:21.817Z
Cvss Version
3.1
State
PUBLISHED

Threat ID: 69a74c95d1a09e29cb79af24

Added to database: 3/3/2026, 9:03:17 PM

Last enriched: 3/3/2026, 9:17:34 PM

Last updated: 3/4/2026, 7:15:02 AM

Views: 11

Community Reviews

0 reviews

Crowdsource mitigation strategies, share intel context, and vote on the most helpful responses. Sign in to add your voice and help keep defenders ahead.

Sort by
Loading community insights…

Want to contribute mitigation steps or threat intel context? Sign in or create an account to join the community discussion.

Actions

PRO

Updates to AI analysis require Pro Console access. Upgrade inside Console → Billing.

Please log in to the Console to use AI analysis features.

Need more coverage?

Upgrade to Pro Console in Console -> Billing for AI refresh and higher limits.

For incident response and remediation, OffSeq services can help resolve threats faster.

Latest Threats

Breach by OffSeqOFFSEQFRIENDS — 25% OFF

Check if your credentials are on the dark web

Instant breach scanning across billions of leaked records. Free tier available.

Scan now
OffSeq TrainingCredly Certified

Lead Pen Test Professional

Technical5-day eLearningPECB Accredited
View courses