CVE-2026-3994: Heap-based Buffer Overflow in rui314 mold

0
Medium
VulnerabilityCVE-2026-3994cvecve-2026-3994
Published: Thu Mar 12 2026 (03/12/2026, 06:02:11 UTC)
Source: CVE Database V5
Vendor/Project: rui314
Product: mold

Description

A vulnerability was detected in rui314 mold up to 2.40.4. This issue affects the function mold::ObjectFilemold::X86_64::initialize_sections of the file src/input-files.cc of the component Object File Handler. Performing a manipulation results in heap-based buffer overflow. Attacking locally is a requirement. The exploit is now public and may be used. The project was informed of the problem early through an issue report but has not responded yet.

AI-Powered Analysis

AILast updated: 03/12/2026, 14:44:39 UTC

Technical Analysis

CVE-2026-3994 identifies a heap-based buffer overflow vulnerability in the mold linker tool developed by rui314, affecting versions 2.40.0 through 2.40.4. The flaw resides in the function mold::ObjectFilemold::X86_64::initialize_sections within the source file src/input-files.cc, part of the Object File Handler component. This function improperly handles certain inputs, allowing an attacker with local access and low privileges to manipulate data in a way that causes a heap overflow. This overflow can corrupt memory, potentially leading to arbitrary code execution, local privilege escalation, or denial of service conditions. The vulnerability does not require user interaction but does require the attacker to have local access and some privileges on the system. The CVSS 4.0 vector indicates low attack complexity and no need for authentication, but limited scope and impact on confidentiality, integrity, and availability. The vulnerability was responsibly disclosed but remains unpatched as of the publication date, and exploit code has been made public, increasing the risk of exploitation. Mold is a high-performance linker used primarily in software development and build environments, so the vulnerability mainly threatens development systems and build servers where mold is used.

Potential Impact

The primary impact of CVE-2026-3994 is on the confidentiality, integrity, and availability of systems running vulnerable versions of mold. Since mold is a linker used in software build processes, exploitation could allow an attacker with local access to execute arbitrary code with the privileges of the user running mold, potentially escalating privileges or disrupting build environments. This could lead to compromised build artifacts, insertion of malicious code during compilation, or denial of service by crashing the linker. Organizations relying on mold in continuous integration/continuous deployment (CI/CD) pipelines or development environments may face risks of supply chain contamination or operational disruption. Although remote exploitation is not possible, insider threats or attackers who have gained limited local access could leverage this vulnerability. The lack of a patch and public exploit availability increases the urgency for mitigation. The impact is mostly confined to development and build infrastructure rather than production runtime environments.

Mitigation Recommendations

To mitigate CVE-2026-3994, organizations should first restrict local access to systems running mold, ensuring only trusted users can execute the linker. Implement strict access controls and monitoring on build servers and developer workstations. Audit usage of mold and identify all systems with affected versions installed. Until an official patch is released, consider temporarily replacing mold with alternative linkers if feasible or running builds inside isolated containers or virtual machines to limit potential damage. Employ runtime protections such as heap memory protection mechanisms (e.g., ASLR, heap canaries) to reduce exploitation success. Monitor public advisories for patches or updates from the rui314 project and apply them promptly once available. Additionally, review build artifacts for integrity and consider implementing reproducible builds to detect tampering. Educate developers and system administrators about the risk of local exploitation and the importance of limiting local privilege escalation vectors.

Pro Console: star threats, build custom feeds, automate alerts via Slack, email & webhooks.Upgrade to Pro

Technical Details

Data Version
5.2
Assigner Short Name
VulDB
Date Reserved
2026-03-11T16:55:36.872Z
Cvss Version
4.0
State
PUBLISHED

Threat ID: 69b2cde02f860ef9439e364f

Added to database: 3/12/2026, 2:29:52 PM

Last enriched: 3/12/2026, 2:44:39 PM

Last updated: 3/14/2026, 2:25:55 AM

Views: 15

Community Reviews

0 reviews

Crowdsource mitigation strategies, share intel context, and vote on the most helpful responses. Sign in to add your voice and help keep defenders ahead.

Sort by
Loading community insights…

Want to contribute mitigation steps or threat intel context? Sign in or create an account to join the community discussion.

Actions

PRO

Updates to AI analysis require Pro Console access. Upgrade inside Console → Billing.

Please log in to the Console to use AI analysis features.

Need more coverage?

Upgrade to Pro Console in Console -> Billing for AI refresh and higher limits.

For incident response and remediation, OffSeq services can help resolve threats faster.

Latest Threats

Breach by OffSeqOFFSEQFRIENDS — 25% OFF

Check if your credentials are on the dark web

Instant breach scanning across billions of leaked records. Free tier available.

Scan now
OffSeq TrainingCredly Certified

Lead Pen Test Professional

Technical5-day eLearningPECB Accredited
View courses