CVE-2026-44411: CWE-824: Access of Uninitialized Pointer in Siemens Solid Edge SE2026
A vulnerability has been identified in Solid Edge SE2026 (All versions < V226.0 Update 5). The affected application is vulnerable to uninitialized pointer access while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process.
AI Analysis
Technical Summary
This vulnerability (CWE-824) in Siemens Solid Edge SE2026 arises from the application accessing an uninitialized pointer while processing specially crafted PAR files. This memory handling flaw can be exploited to achieve arbitrary code execution within the context of the current process. The CVSS 3.1 base score is 7.8, reflecting high impact on confidentiality, integrity, and availability, with attack vector local and requiring user interaction but no privileges. The affected versions include all releases before V226.0 Update 5. No patch or official remediation guidance has been published by Siemens as of the data provided.
Potential Impact
An attacker who can supply a malicious PAR file to the vulnerable Solid Edge SE2026 application could execute arbitrary code with the same privileges as the user running the software. This could lead to full compromise of the affected system's confidentiality, integrity, and availability. The vulnerability requires local access and user interaction to trigger.
Mitigation Recommendations
Patch status is not yet confirmed — check the Siemens vendor advisory for current remediation guidance. Until an official fix is released, avoid opening untrusted PAR files with Solid Edge SE2026. Monitor Siemens communications for updates on patches or mitigations.
CVE-2026-44411: CWE-824: Access of Uninitialized Pointer in Siemens Solid Edge SE2026
Description
A vulnerability has been identified in Solid Edge SE2026 (All versions < V226.0 Update 5). The affected application is vulnerable to uninitialized pointer access while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process.
AI-Powered Analysis
Machine-generated threat intelligence
Technical Analysis
This vulnerability (CWE-824) in Siemens Solid Edge SE2026 arises from the application accessing an uninitialized pointer while processing specially crafted PAR files. This memory handling flaw can be exploited to achieve arbitrary code execution within the context of the current process. The CVSS 3.1 base score is 7.8, reflecting high impact on confidentiality, integrity, and availability, with attack vector local and requiring user interaction but no privileges. The affected versions include all releases before V226.0 Update 5. No patch or official remediation guidance has been published by Siemens as of the data provided.
Potential Impact
An attacker who can supply a malicious PAR file to the vulnerable Solid Edge SE2026 application could execute arbitrary code with the same privileges as the user running the software. This could lead to full compromise of the affected system's confidentiality, integrity, and availability. The vulnerability requires local access and user interaction to trigger.
Mitigation Recommendations
Patch status is not yet confirmed — check the Siemens vendor advisory for current remediation guidance. Until an official fix is released, avoid opening untrusted PAR files with Solid Edge SE2026. Monitor Siemens communications for updates on patches or mitigations.
Technical Details
- Data Version
- 5.2
- Assigner Short Name
- siemens
- Date Reserved
- 2026-05-06T09:51:05.262Z
- Cvss Version
- 3.1
- State
- PUBLISHED
- Remediation Level
- null
Threat ID: 6a02f11acbff5d8610c13ae9
Added to database: 5/12/2026, 9:21:30 AM
Last enriched: 5/12/2026, 9:36:35 AM
Last updated: 5/12/2026, 4:30:32 PM
Views: 9
Community Reviews
0 reviewsCrowdsource mitigation strategies, share intel context, and vote on the most helpful responses. Sign in to add your voice and help keep defenders ahead.
Want to contribute mitigation steps or threat intel context? Sign in or create an account to join the community discussion.
Actions
Updates to AI analysis require Pro Console access. Upgrade inside Console → Billing.
External Links
Need more coverage?
Upgrade to Pro Console for AI refresh and higher limits.
For incident response and remediation, OffSeq services can help resolve threats faster.
Latest Threats
Check if your credentials are on the dark web
Instant breach scanning across billions of leaked records. Free tier available.