CVE-2026-62652: CWE-215: Insertion of Sensitive Information Into Debugging Code in Siemens Reyrolle 7SR5

0
Medium
VulnerabilityCVE-2026-62652cvecve-2026-62652cwe-215
Published: 09/08/2026 (09/08/2026, 08:11:33 UTC)
Source: CVE Database V5
Vendor/Project: Siemens
Product: Reyrolle 7SR5

Description

A vulnerability has been identified in Reyrolle 7SR5 (All versions < V2.70). The device firmware contains binaries from which debugging symbols have not been removed. This could allow an unauthenticated attacker with access to the publicly available firmware update files to more easily reverse engineer the device's firmware, facilitating the identification of further vulnerabilities.

CVSS v3.1

Score 5.3medium

Attack Vector
Network
Attack Complexity
Low
Privileges Required
None
User Interaction
None
Scope
Unchanged
Confidentiality
Low
Integrity
None
Availability
None
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N

Affected software

Siemens

Reyrolle 7SR5

Affected versions
>=0 <2.70

AI-Powered Analysis

Machine-generated threat intelligence

AILast updated: 09/16/2026, 01:36:54 UTC

Technical Analysis

The vulnerability identified as CVE-2026-62652 affects Siemens Reyrolle 7SR5 devices with firmware versions earlier than 2.70. The issue arises because debugging symbols remain embedded in the firmware binaries distributed via public update files. These symbols can aid an unauthenticated attacker in reverse engineering the firmware, which may help in identifying further security weaknesses. The CVSS 3.1 base score is 5.3, reflecting a medium impact primarily due to confidentiality loss. There is no indication of integrity or availability impact. No vendor advisory or patch information is currently available.

Potential Impact

The vulnerability allows an unauthenticated attacker with access to publicly available firmware update files to gain additional information through debugging symbols embedded in the firmware. This exposure can lower the effort required to reverse engineer the device firmware and potentially discover further vulnerabilities. The impact is limited to confidentiality as per the CVSS vector, with no direct integrity or availability consequences reported.

Mitigation Recommendations

Patch status is not yet confirmed — check the vendor advisory for current remediation guidance. Until an official fix is released, organizations should restrict access to firmware update files where possible and monitor for updates from Siemens regarding remediation.

Pro Console: star threats, build custom feeds, automate alerts via Slack, email & webhooks.Upgrade to Pro

Technical Details

Data Version
5.2
Assigner Short Name
siemens
Date Reserved
2026-07-14T16:24:23.430Z
Cvss Version
3.1
State
PUBLISHED

Threat ID: 6a9fc954acd9273b49571d96

Added to database: 09/08/2026, 08:37:40 UTC

Last enriched: 09/16/2026, 01:36:54 UTC

Last updated: 10/23/2026, 01:15:25 UTC

Views: 88

Community Reviews

0 reviews

Crowdsource mitigation strategies, share intel context, and vote on the most helpful responses. Sign in to add your voice and help keep defenders ahead.

Sort by
Loading community insights…

Want to contribute mitigation steps or threat intel context? Sign in or create an account to join the community discussion.

Actions

PRO

Updates to AI analysis require Pro Console access. Upgrade inside Console → Billing.

Please log in to the Console to use AI analysis features.

Need more coverage?

Upgrade to Pro Console for AI refresh and higher limits.

For incident response and remediation, OffSeq services can help resolve threats faster.

Latest Threats

Breach by OffSeqOFFSEQFRIENDS — 25% OFF

Check if your credentials are on the dark web

Instant breach scanning across billions of leaked records. Free tier available.

Scan now
OffSeq TrainingCredly Certified

Lead Pen Test Professional

Technical5-day eLearningPECB Accredited
View courses