CVE-2026-7160: Command Injection in Tenda HG3
A vulnerability was determined in Tenda HG3 2.0. This vulnerability affects the function formTracert of the file /boaform/formTracert. Executing a manipulation of the argument datasize can lead to command injection. The attack may be performed from remote. The exploit has been publicly disclosed and may be utilized.
AI Analysis
Technical Summary
This vulnerability in Tenda HG3 2.0 involves improper handling of the 'datasize' argument in the formTracert function located at /boaform/formTracert. An attacker can manipulate this argument to inject and execute arbitrary commands on the affected device remotely. The CVSS 4.0 base score is 8.7, indicating a high severity with network attack vector, no privileges required, no user interaction, and high impact on confidentiality, integrity, and availability. The vulnerability is publicly disclosed but lacks an official fix or vendor advisory at this time.
Potential Impact
Successful exploitation allows an unauthenticated remote attacker to execute arbitrary commands on the affected Tenda HG3 device, potentially leading to full compromise of the device. This can impact confidentiality, integrity, and availability of the device and its network environment. No known exploits in the wild have been reported yet.
Mitigation Recommendations
Patch status is not yet confirmed — check the vendor advisory for current remediation guidance. Until an official fix is available, restrict access to the device management interface from untrusted networks and monitor for suspicious activity related to the formTracert function. Do not expose the device management interface directly to the internet.
CVE-2026-7160: Command Injection in Tenda HG3
Description
A vulnerability was determined in Tenda HG3 2.0. This vulnerability affects the function formTracert of the file /boaform/formTracert. Executing a manipulation of the argument datasize can lead to command injection. The attack may be performed from remote. The exploit has been publicly disclosed and may be utilized.
AI-Powered Analysis
Machine-generated threat intelligence
Technical Analysis
This vulnerability in Tenda HG3 2.0 involves improper handling of the 'datasize' argument in the formTracert function located at /boaform/formTracert. An attacker can manipulate this argument to inject and execute arbitrary commands on the affected device remotely. The CVSS 4.0 base score is 8.7, indicating a high severity with network attack vector, no privileges required, no user interaction, and high impact on confidentiality, integrity, and availability. The vulnerability is publicly disclosed but lacks an official fix or vendor advisory at this time.
Potential Impact
Successful exploitation allows an unauthenticated remote attacker to execute arbitrary commands on the affected Tenda HG3 device, potentially leading to full compromise of the device. This can impact confidentiality, integrity, and availability of the device and its network environment. No known exploits in the wild have been reported yet.
Mitigation Recommendations
Patch status is not yet confirmed — check the vendor advisory for current remediation guidance. Until an official fix is available, restrict access to the device management interface from untrusted networks and monitor for suspicious activity related to the formTracert function. Do not expose the device management interface directly to the internet.
Technical Details
- Data Version
- 5.2
- Assigner Short Name
- VulDB
- Date Reserved
- 2026-04-26T20:17:52.059Z
- Cvss Version
- 4.0
- State
- PUBLISHED
- Remediation Level
- null
Threat ID: 69efd8e1ba26a39fba67dee1
Added to database: 4/27/2026, 9:45:05 PM
Last enriched: 4/27/2026, 10:00:06 PM
Last updated: 4/27/2026, 11:39:44 PM
Views: 6
Community Reviews
0 reviewsCrowdsource mitigation strategies, share intel context, and vote on the most helpful responses. Sign in to add your voice and help keep defenders ahead.
Want to contribute mitigation steps or threat intel context? Sign in or create an account to join the community discussion.
Actions
Updates to AI analysis require Pro Console access. Upgrade inside Console → Billing.
Need more coverage?
Upgrade to Pro Console for AI refresh and higher limits.
For incident response and remediation, OffSeq services can help resolve threats faster.
Latest Threats
Check if your credentials are on the dark web
Instant breach scanning across billions of leaked records. Free tier available.