Skip to main content
VulnerabilityPublished Updated

CVE-2026-80276: Comelit Group S.p.A 1456B Multi-User Gateway · Missing Authentication

Affects Comelit Group S.p.A 1456B Multi-User GatewaySource CVE Database V5

0
Compare

Not known to be exploited · CVSS 7.5 High.

Data as of 15 Nov 2026, 20:25 UTC

CVSS 3.1 base score
7.5High
How severe the flaw is on the 0–10 CVSS scale.
EPSS
0.3% chance of exploitation in 30 days – higher than 31% of CVEsExploit Prediction Scoring System: the likelihood attackers will use this flaw soon.
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N

Exploitation evidence

  1. Disclosed: evidence found.

    CVE published 1 Oct 2026

  2. Detectable: no evidence on record.

    No public nuclei template indexed

  3. Weaponized: no evidence on record.

    No public exploit code indexed in Metasploit or Exploit-DB

  4. Exploited in the wild: no evidence on record.

    Not in CISA KEV and no source reports exploitation

  5. Observed by OffSeq Mirage: no evidence on record.

    No attack traffic recorded by OffSeq Mirage sensors

A missing step is not evidence of safety. Sources: cve.org (opens in a new tab), the Metasploit, Exploit-DB and nuclei-templates index as of 15 Nov 2026.

What to do

Affected software

ProductAffectedFixed in
Comelit Group S.p.A.1456B Multi-User GatewayAffected
  • =2.9.1
  • =2.10.0
Fixed in–

AI-suggested

Until a fix is available, restrict network access to the management interface to trusted hosts only to reduce exposure.

Description

The Comelit 1456B Multi-User Gateway firmware versions 2.9.1 and 2.10.0 have a vulnerability where the network-accessible management interface does not require authentication. This allows a remote, unauthenticated attacker to read sensitive device configuration data, including the Remote Configuration Password, in cleartext.

References

Community reviews