CWE-319 in Apollo Pharmacy Blood Glucose Monitoring System (Model No. APG-01 BT) (CVE-2026-50034)
CVE-2026-50034 affects the Apollo Pharmacy Blood Glucose Monitoring System (Model No. APG-01 BT). An attacker within Bluetooth Low Energy (BLE) communication range can passively intercept wireless traffic and obtain sensitive health-related information, specifically glucose measurement values. This vulnerability is classified under CWE-319, indicating the transmission of sensitive information in an unprotected manner. The CVSS 3.1 base score is 6.5, reflecting a medium severity level. No patches or fixes are currently documented for this vulnerability. The device is not a cloud service, so remediation depends on vendor updates or device replacement.
AI Analysis
Technical Summary
The vulnerability CVE-2026-50034 in the Apollo Pharmacy Blood Glucose Monitoring System (Model No. APG-01 BT) allows an attacker within BLE range to passively intercept unencrypted wireless communications. This enables the attacker to obtain sensitive health data, including glucose measurement values, without requiring user interaction or privileges. The issue is categorized as CWE-319, which involves the exposure of sensitive information through unprotected communication channels. The CVSS vector indicates the attack requires adjacent network access (BLE range), has low attack complexity, no privileges or user interaction needed, and impacts confidentiality but not integrity or availability.
Potential Impact
An attacker within BLE range can eavesdrop on wireless traffic from the affected device and access sensitive health information such as glucose measurements. This compromises the confidentiality of personal health data. There is no indication of impact on data integrity or device availability. The vulnerability does not require user interaction or elevated privileges, increasing the risk of passive data leakage.
Mitigation Recommendations
No official patch or remediation is currently available for this vulnerability. Since the device is not a cloud service, remediation depends on the vendor providing a firmware update or device replacement. Users should be informed about the risk of passive data interception over BLE and consider limiting physical proximity of untrusted parties to the device. Monitor vendor advisories for updates or fixes addressing this issue.
CWE-319 in Apollo Pharmacy Blood Glucose Monitoring System (Model No. APG-01 BT) (CVE-2026-50034)
Description
CVE-2026-50034 affects the Apollo Pharmacy Blood Glucose Monitoring System (Model No. APG-01 BT). An attacker within Bluetooth Low Energy (BLE) communication range can passively intercept wireless traffic and obtain sensitive health-related information, specifically glucose measurement values. This vulnerability is classified under CWE-319, indicating the transmission of sensitive information in an unprotected manner. The CVSS 3.1 base score is 6.5, reflecting a medium severity level. No patches or fixes are currently documented for this vulnerability. The device is not a cloud service, so remediation depends on vendor updates or device replacement.
CVSS v3.1
Score 6.5medium
Weaknesses
AI-Powered Analysis
Machine-generated threat intelligence
Technical Analysis
The vulnerability CVE-2026-50034 in the Apollo Pharmacy Blood Glucose Monitoring System (Model No. APG-01 BT) allows an attacker within BLE range to passively intercept unencrypted wireless communications. This enables the attacker to obtain sensitive health data, including glucose measurement values, without requiring user interaction or privileges. The issue is categorized as CWE-319, which involves the exposure of sensitive information through unprotected communication channels. The CVSS vector indicates the attack requires adjacent network access (BLE range), has low attack complexity, no privileges or user interaction needed, and impacts confidentiality but not integrity or availability.
Potential Impact
An attacker within BLE range can eavesdrop on wireless traffic from the affected device and access sensitive health information such as glucose measurements. This compromises the confidentiality of personal health data. There is no indication of impact on data integrity or device availability. The vulnerability does not require user interaction or elevated privileges, increasing the risk of passive data leakage.
Mitigation Recommendations
No official patch or remediation is currently available for this vulnerability. Since the device is not a cloud service, remediation depends on the vendor providing a firmware update or device replacement. Users should be informed about the risk of passive data interception over BLE and consider limiting physical proximity of untrusted parties to the device. Monitor vendor advisories for updates or fixes addressing this issue.
Technical Details
- Gcve Source
- db.gcve.eu
- Csaf Category
- csaf_security_advisory
- Csaf Version
- 2.0
- Publisher
- CISA
- Advisory Id
- ICSMA-26-169-01
- Cve Count
- 2
- Additional Cves
- ["CVE-2026-52866"]
- Cvss Version
- null
Threat ID: 6a343a2df198dc38c148e4ee
Added to database: 06/18/2026, 18:34:21 UTC
Last enriched: 06/25/2026, 20:08:30 UTC
Last updated: 07/31/2026, 19:22:59 UTC
Views: 142
Community Reviews
0 reviewsCrowdsource mitigation strategies, share intel context, and vote on the most helpful responses. Sign in to add your voice and help keep defenders ahead.
Want to contribute mitigation steps or threat intel context? Sign in or create an account to join the community discussion.
Actions
Updates to AI analysis require Pro Console access. Upgrade inside Console → Billing.
Need more coverage?
Upgrade to Pro Console for AI refresh and higher limits.
For incident response and remediation, OffSeq services can help resolve threats faster.
Latest Threats
Check if your credentials are on the dark web
Instant breach scanning across billions of leaked records. Free tier available.