CVE-2026-45582: n8n-MCP · Workflow telemetry sanitizer could retain partial values from URL-shaped node parameters
Affects n8n-mcpSource GCVE Database
Not known to be exploited · CVSS 6.5 Medium : upgrade to 2.51.3 when convenient.
Data as of 26 Oct 2026, 17:16 UTC
- EPSS
- 0.2% chance of exploitation in 30 days – higher than 17% of CVEsExploit Prediction Scoring System: the likelihood attackers will use this flaw soon.
- Patch
- Available – fixed in 2.51.3
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:NExploitation evidence
Disclosed: evidence found.
CVE published 29 May 2026
Detectable: no evidence on record.
No public nuclei template indexed
Weaponised: no evidence on record.
No public exploit code indexed in Metasploit or Exploit-DB
Exploited in the wildExploited: no evidence on record.
Not in CISA KEV and no source reports exploitation
Observed by OffSeq MirageSeen by Mirage: no evidence on record.
No attack traffic recorded by OffSeq Mirage sensors
A missing step is not evidence of safety. Sources: cve.org (opens in a new tab), the Metasploit, Exploit-DB and nuclei-templates index as of 26 Oct 2026.
What to do
Upgrade n8n-mcp to 2.51.3.
Affected software
| Product | Affected | Fixed in |
|---|---|---|
Homebrewn8n-mcppkg:brew/n8n-mcpOther threats | Affected
| Fixed in
|
Check your own hosts for these packages with threat-finder (opens in a new tab), our free open-source scanner.
AI-suggested
Upgrade n8n-mcp to version 2.51.3 or later to apply the official fix. For users unable to upgrade immediately, disable anonymous telemetry by setting any of the environment variables N8N_MCP_TELEMETRY_DISABLED, TELEMETRY_DISABLED, or DISABLE_TELEMETRY to true.
Description
A vulnerability in n8n-mcp versions from 2.14.1 up to but not including 2.51.3 allows partial fragments of URL-shaped node parameters to be retained in workflow telemetry data sent to the anonymous telemetry backend. This may expose sensitive information such as customer or tenant identifiers and short secrets embedded in query strings. The issue does not affect credentials, OAuth tokens, or workflow execution data. The vulnerability is fixed in version 2.51.3. Users unable to upgrade immediately can disable telemetry via environment variables.
References
- github.com/czlonkowski/n8n-mcp/security/advisories/GHSA-f3rg-xqjj-cj9w (opens in a new tab)
- nvd.nist.gov/vuln/detail/CVE-2026-45582 (opens in a new tab)
- github.com/czlonkowski/n8n-mcp/pull/782 (opens in a new tab)
- github.com/czlonkowski/n8n-mcp/commit/6cf6fef653fcd6d598f2f356aac4754931c7329f (opens in a new tab)