Skip to main content
CVE-2026-115794VulnerabilityPublished

P-Net before 1.0.3 passes the application alarm callback a data length derived from the variable part length field of

Source GCVE Database

0
Compare
Authoritative record:CVE-2026-115794· Low 2.3

Not known to be exploited · CVSS 2.3 Low : upgrade to 1.0.3 when convenient.

Data as of 29 Oct 2026, 19:46 UTC

CVSS 4.0 base score
2.3Low
How severe the flaw is on the 0–10 CVSS scale.

Thin evidence

One scorer or none
CVSS scores by source
CNA (rt-labs)CVSS 4.02.3
Patch
Available – fixed in 1.0.3
CVSS:4.0/AV:A/AC:L/AT:P/PR:N/UI:N/VC:L/VI:N/VA:L/SC:N/SI:N/SA:N

Exploitation evidence

  1. Disclosed: evidence found.

    CVE published 29 Oct 2026

  2. Detectable: no evidence on record.

    No public nuclei template indexed

  3. Weaponized: no evidence on record.

    No public exploit code indexed in Metasploit or Exploit-DB

  4. Exploited in the wild: no evidence on record.

    Not in CISA KEV and no source reports exploitation

  5. Observed by OffSeq Mirage: no evidence on record.

    No attack traffic recorded by OffSeq Mirage sensors

A missing step is not evidence of safety. Sources: cve.org (opens in a new tab), the Metasploit, Exploit-DB and nuclei-templates index as of 29 Oct 2026.

What to do

Upgrade P-Net to 1.0.3.

Affected software

ProductAffectedFixed in
RT-LabsP-NetAffected
  • <1.0.3
Fixed in
  • 1.0.3

AI-suggested

Since the vulnerability affects versions before 1.0.3, upgrading to version 1.0.3 or later (if available) is recommended once a fix is confirmed. Until then, applications that do not use the alarm data are not affected. Restricting network access to prevent adjacent attackers from establishing an Application Relationship may reduce risk.

Description

P-Net versions before 1.0.3 contain a vulnerability where the application alarm callback receives a data length derived from a variable part length field without verifying it against the actual frame length. This can cause the callback to process an excessively large length value, leading to out-of-bounds reads if the application copies that many bytes. Exploitation requires an established Application Relationship and adjacent network access. Applications that do not use the alarm data are not affected.