A vulnerability has been identified in Solid Edge SE2025 (All versions < V225.0 Update 5). The affected applications contain a stack based overflow vulnerability while parsing specially crafted CFG files.
This could allow an attacker to execute code in the context of the current process.
A vulnerability has been identified in Solid Edge SE2025 (All versions < V225.0 Update 5). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files.
This could allow an attacker to execute code in the context of the current process.
A vulnerability has been identified in Solid Edge SE2025 (All versions < V225.0 Update 5). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files.
This could allow an attacker to execute code in the context of the current process.
A vulnerability has been identified in SINEC NMS (All versions < V4.0). The affected application does not properly validate file paths when extracting uploaded ZIP files. This could allow an attacker to write arbitrary files to restricted locations and potentially execute code with elevated privileges (ZDI-CAN-26572).
A vulnerability has been identified in SINEC NMS (All versions < V4.0). The affected application does not properly validate file paths when extracting uploaded ZIP files. This could allow an attacker to write arbitrary files to restricted locations and potentially execute code with elevated privileges (ZDI-CAN-26571).
A vulnerability has been identified in SINEC NMS (All versions < V4.0). The affected application exposes an endpoint that allows an unauthorized modification of administrative credentials. This could allow an unauthenticated attacker to reset the superadmin password and gain full control of the application (ZDI-CAN-26569).
A vulnerability has been identified in SINEC NMS (All versions < V4.0). The affected devices are vulnerable to SQL injection. This could allow an unauthenticated remote attacker to execute arbitrary SQL queries on the server database.
A vulnerability has been identified in SIMATIC CN 4100 (All versions < V4.0). The affected application allows to control the device by storing arbitrary files in the SFTP folder of the device. This could allow an attacker to cause a denial of service condition.
A vulnerability has been identified in TIA Project-Server (All versions < V2.1.1), TIA Project-Server V17 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions), Totally Integrated Automation Portal (TIA Portal) V18 (All versions), Totally Integrated Automation Portal (TIA Portal) V19 (All versions < V19 Update 4), Totally Integrated Automation Portal (TIA Portal) V20 (All versions < V20 Update 3). The affected application improperly handles uploaded projects in the document root. This could allow an attacker with contributor privileges to cause denial of service by uploading a malicious project.
A vulnerability has been identified in TIA Administrator (All versions < V3.0.6). The affected application allows low-privileged users to trigger installations by overwriting cache files and modifying the downloads path. This would allow an attacker to escalate privilege and exceute arbitrary code.
A vulnerability has been identified in TIA Administrator (All versions < V3.0.6). The affected application improperly validates code signing certificates.
This could allow an attacker to bypass the check and exceute arbitrary code during installations.
A vulnerability has been identified in Mendix Studio Pro 10 (All versions < V10.24.24 for Windows), Mendix Studio Pro 10 (All versions < V10.24.24 for Mac), Mendix Studio Pro 11 (All versions < V11.13.0 for Windows), Mendix Studio Pro 11 (All versions < V11.13.0 for Mac), Mendix Studio Pro 11.12 (All versions < V11.12.2 for Windows), Mendix Studio Pro 11.12 (All versions < V11.12.2 for Mac), Mendix Studio Pro 11.6 (All versions < V11.6.9 for Windows), Mendix Studio Pro 11.6 (All versions < V11.6.9 for Mac), Mendix Studio Pro 9 (All versions < V9.24.44 for Windows). A zip path traversal vulnerability exists in the module installation process of Studio Pro. By crafting a malicious module and distributing it via (for example) the Mendix Marketplace, an attacker could write or modify arbitrary files in directories outside a developer’s project directory upon module installation.
A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.16.5), RUGGEDCOM ROX MX5000RE (All versions < V2.16.5), RUGGEDCOM ROX RX1400 (All versions < V2.16.5), RUGGEDCOM ROX RX1500 (All versions < V2.16.5), RUGGEDCOM ROX RX1501 (All versions < V2.16.5), RUGGEDCOM ROX RX1510 (All versions < V2.16.5), RUGGEDCOM ROX RX1511 (All versions < V2.16.5), RUGGEDCOM ROX RX1512 (All versions < V2.16.5), RUGGEDCOM ROX RX1524 (All versions < V2.16.5), RUGGEDCOM ROX RX1536 (All versions < V2.16.5), RUGGEDCOM ROX RX5000 (All versions < V2.16.5). The 'Log Viewers' tool in the web interface of affected devices is vulnerable to command injection due to missing server side input sanitation. This could allow an authenticated remote attacker to execute the 'tail' command with root privileges and disclose contents of all files in the filesystem.
A vulnerability has been identified in Energy Services (All versions with G5DFR). Affected solutions using G5DFR contain default credentials. This could allow an attacker to gain control of G5DFR component and tamper with outputs from the device.
A vulnerability has been identified in Mendix Runtime V10 (All versions < V10.21.0), Mendix Runtime V10.12 (All versions < V10.12.16), Mendix Runtime V10.18 (All versions < V10.18.5), Mendix Runtime V10.6 (All versions < V10.6.22), Mendix Runtime V8 (All versions < V8.18.35), Mendix Runtime V9 (All versions < V9.24.34). Affected applications allow for entity enumeration due to distinguishable responses in certain client actions. This could allow an unauthenticated remote attacker to list all valid entities and attribute names of a Mendix Runtime-based application.