The WorkExaminer Professional server installation comes with an FTP server that is used to receive the client logs on TCP port 12304. An attacker with network access to this port can use weak hardcoded credentials to login to the FTP server and modify or read data, log files and gain remote code execution as NT Authority\SYSTEM on the server by exchanging accessible service binaries in the WorkExaminer installation directory (e.g. "C:\Program File (x86)\Work Examiner Professional Server").
An Use of Hard-coded Credentials vulnerability has been identified in Moxa’s network security appliances and routers. The system employs a hard-coded secret key to sign JSON Web Tokens (JWT) used for authentication. This insecure implementation allows an unauthenticated attacker to forge valid tokens, thereby bypassing authentication controls and impersonating any user. Exploitation of this vulnerability can result in complete system compromise, enabling unauthorized access, data theft, and full administrative control over the affected device. While successful exploitation can severely impact the confidentiality, integrity, and availability of the affected device itself, there is no loss of confidentiality or integrity within any subsequent systems.
The Felan Framework plugin for WordPress is vulnerable to improper authentication in versions up to, and including, 1.1.4. This is due to the hardcoded password in the 'fb_ajax_login_or_register' function and in the 'google_ajax_login_or_register' function. This makes it possible for unauthenticated attackers to log in as any existing user on the site, if they registered with facebook or google social login and did not change their password. CVE-2025-23504 is likely a duplicate of this issue.
IBM Security Verify Access 10.0.0 through 10.0.9, 11.0.0, IBM Verify Identity Access Container 10.0.0 through 10.0.9, and 11.0.0, under certain configurations, contains hard-coded credentials, such as a password or cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data.
Allstar is a GitHub App to set and enforce security policies. In versions prior to 4.5, a vulnerability in Allstar’s Reviewbot component caused inbound webhook requests to be validated against a hard-coded, shared secret. The value used for the secret token was compiled into the Allstar binary and could not be configured at runtime. In practice, this meant that every deployment using Reviewbot would validate requests with the same secret unless the operator modified source code and rebuilt the component - an expectation that is not documented and is easy to miss. All Allstar releases prior to v4.5 that include the Reviewbot code path are affected. Deployments on v4.5 and later are not affected. Those who have not enabled or exposed the Reviewbot endpoint are not exposed to this issue.
Use of Hard-coded Credentials vulnerability in Logo Software Inc. TigerWings ERP allows Read Sensitive Constants Within an Executable.
This issue affects TigerWings ERP: from 01.01.00 before 3.03.00.
Use of Hard-coded Credentials, Authorization Bypass Through User-Controlled Key vulnerability in PosCube Hardware Software and Consulting Ltd. Co. Assist allows Excavation, Authentication Bypass.
This issue affects Assist: through 10.02.2025.
Vasion Print (formerly PrinterLogic) Virtual Appliance Host prior to version 22.0.1049 and Application prior to version 20.0.2786 (VA/SaaS deployments) contain a default admin account and an installation‑time endpoint at `/admin/query/update_database.php` that can be accessed without authentication. An attacker who can reach the installation web interface can POST arbitrary `root_user` and `root_password` values, causing the script to replace the default admin credentials with attacker‑controlled ones. The script also contains hard‑coded SHA‑512 and SHA‑1 hashes of the default password, allowing the attacker to bypass password‑policy validation. As a result, an unauthenticated remote attacker can obtain full administrative control of the system during the initial setup. This vulnerability has been identified by the vendor as: V-2024-022 — Insecure Installation Credentials.
Vasion Print (formerly PrinterLogic) Virtual Appliance Host prior to 22.0.862 and Application prior to 20.0.2014 (VA and SaaS deployments) contain Docker images with the private GPG key and passphrase for the account *no‑reply+virtual‑appliance@printerlogic.com*. The key is stored in cleartext and the passphrase is hardcoded in files. An attacker with administrative access to the appliance can extract the private key, import it into their own system, and subsequently decrypt GPG-encrypted files and sign arbitrary firmware update packages. A maliciously signed update can be uploaded by an admin‑level attacker and will be executed by the appliance, giving the attacker full control of the virtual appliance. This vulnerability has been identified by the vendor as: V-2023-010 — Hardcoded Private Key.
Vasion Print (formerly PrinterLogic) Virtual Appliance Host versions prior to 25.1.102 and Application prior to 25.1.1413 (Windows client deployments) contain a hardcoded private key for the PrinterLogic Certificate Authority (CA) and a hardcoded password in product configuration files. The Windows client ships the CA certificate and its associated private key (and other sensitive settings such as a configured password) directly in shipped configuration files (for example clientsettings.dat and defaults.ini). An attacker who obtains these files can impersonate the CA, sign arbitrary certificates trusted by the Windows client, intercept or decrypt TLS-protected communications, and otherwise perform man-in-the-middle or impersonation attacks against the product's network communications. This vulnerability has been identified by the vendor as: V-2022-001 — Configuration File Contains CA & Private Key.
Vasion Print (formerly PrinterLogic) Virtual Appliance Host versions prior to 22.0.951 and Application prior to 20.0.2368 (VA and SaaS deployments) contain shared, hardcoded SSH host private keys in the appliance image. The same private host keys (RSA, ECDSA, and ED25519) are present across installations, rather than being uniquely generated per appliance. An attacker who obtains these private keys (for example from one compromised appliance image or another installation) can impersonate the appliance, decrypt or intercept SSH connections to appliances that use the same keys, and perform man-in-the-middle or impersonation attacks against administrative SSH sessions. This vulnerability has been identified by the vendor as: V-2024-011 — Hardcoded SSH Host Key.
Vasion Print (formerly PrinterLogic) Virtual Appliance Host versions prior to 22.0.951, Application prior to 20.0.2368 (VA and SaaS deployments) contain an undocumented local user account named ubuntu with a preset password and a sudoers entry granting that account passwordless root privileges (ubuntu ALL=(ALL) NOPASSWD: ALL). Anyone who knows the hardcoded password can obtain root privileges via local console or equivalent administrative access, enabling local privilege escalation. This vulnerability has been identified by the vendor as: V-2024-010 — Hardcoded Linux Password. NOTE: The patch for this vulnerability is reported to be incomplete: /etc/shadow was remediated but /etc/sudoers remains vulnerable.
The BeyondCart Connector plugin for WordPress is vulnerable to Privilege Escalation due to improper JWT secret management and authorization within the determine_current_user filter in versions 1.4.2 through 3.0.1. This makes it possible for unauthenticated attackers to craft valid tokens and assume any user’s identity.
PTZOptics and possibly other ValueHD-based pan-tilt-zoom cameras use hard-coded, default administrative credentials. The passwords can readily be cracked. Many cameras have SSH or telnet listening on all interfaces. The passwords cannot be changed by the user, nor can the SSH or telnet service be disabled by the user.
ECOVACS robot vacuums and base stations communicate via an insecure Wi-Fi network with a deterministic AES encryption key, which can be easily derived.
The SunPower PVS6's BluetoothLE interface is vulnerable due to its use of hardcoded encryption parameters and publicly accessible protocol details. An attacker within Bluetooth range could exploit this vulnerability to gain full access to the device's servicing interface. This access allows the attacker to perform actions such as firmware replacement, disabling power production, modifying grid settings, creating SSH tunnels, altering firewall settings, and manipulating connected devices.