Skip to main content
Press slash or control plus K to focus the search. Use the arrow keys to navigate results and press enter to open a threat.

Threats Tagged 'cve-2026-78422'

View all threats tagged with 'cve-2026-78422'. Filter and sort to focus on specific types of threats.

Pro Console Lifetime

Stop chasing alerts. Route them.

Start free, then upgrade once to turn Radar into an automated delivery engine for your security stack.

Custom feeds / Automations: email, Slack, webhooks, SIEM/MISP / API access (baseline limits)

View Plans & Pricing

API access activates after upgrading in Console -> Billing.

Breach by OffSeqOFFSEQFRIENDS — 25% OFF

Check if your credentials are on the dark web

Instant breach scanning across billions of leaked records. Free tier available.

Scan now

Filter Threats

Narrow down the results by type, severity, or affected countries

Search threats by title, CVE ID, or description. Maximum 100 characters.
Active filters (1):Tag: cve-2026-78422

Threats Tagged 'cve-2026-78422'

Click on any threat for detailed analysis and mitigation recommendations

CVE-2026-78422: CWE-686 Function call with incorrect argument type in z-galaxy zbus_polkitCVE-2026-78422
0

Subject::new_for_owner() in the zbus_polkit crate encodes the uid entry of a unix-process polkit subject as an unsigned 32-bit integer (D-Bus type u), whereas the org.freedesktop.PolicyKit1.Authority interface specifies a signed 32-bit integer (D-Bus type i). Because of this type mismatch, polkit silently discards the caller-supplied UID and instead determines the subject's owner itself by looking up the PID in /proc, a lookup that is inherently subject to a time-of-check/time-of-use race. Consequently, an application that passes a UID obtained from a trustworthy source — for example SO_PEERCRED Unix socket peer credentials — in order to defend against PID reuse receives no protection, and the supplied UID has no effect on the authorization decision. A local unprivileged attacker who can cause an authorized process to terminate and then win the race to have their own process assigned the same PID can be authorized under the identity of the terminated process, bypassing the polkit authorization check and performing actions the attacker is not entitled to. This issue affects zbus_polkit before 5.1.0.

Join the discussion

Showing 1 to 1 of 1 result

Filters:Tag: cve-2026-78422
Page 1 of 1
OffSeq TrainingCredly Certified

Lead Pen Test Professional

Technical5-day eLearningPECB Accredited
View courses