Skip to main content

Threats Tagged 'cwe-790'

View all threats tagged with 'cwe-790'. Filter and sort to focus on specific types of threats.

Pro Console Lifetime

Stop chasing alerts. Route them.

Start free, then upgrade once to turn Radar into an automated delivery engine for your security stack.

Custom feeds / Automations: email, Slack, webhooks, SIEM/MISP / API access (baseline limits)

View Plans & Pricing

API access activates after upgrading in Console -> Billing.

Breach by OffSeqOFFSEQFRIENDS — 25% OFF

Check if your credentials are on the dark web

Instant breach scanning across billions of leaked records. Free tier available.

Scan now

Filter Threats

Narrow down the results by type, severity, or affected countries

Search threats by title, CVE ID, or description. Maximum 100 characters.
Active filters (1):Tag: cwe-790

Threats Tagged 'cwe-790'

Click on any threat for detailed analysis and mitigation recommendations

An attacker who knows (or guesses) that a resolver uses RPZ with wildcard CNAME policies can craft query names long enough to trigger a NAMETOOLONG error condition during RPZ processing. This is not handled correctly and may lead to defeating the RPZ rule. It also may lead to an unexpected exit of the BIND 9 software. This issue affects BIND 9 versions 9.16.0 through 9.18.50, 9.20.0 through 9.20.24, 9.21.0 through 9.21.23, 9.16.8-S1 through 9.18.50-S1, and 9.20.9-S1 through 9.20.24-S1.

Join the discussion

Plack::Middleware::Security::Common versions before 0.13.1 for Perl did not block header injections in request paths. The header injection rule was ineffective at blocking header injections in the request paths unless they were double-encoded, for example, GET /path\r\nHTTP/1.1\r\nHost: secret.example.com Note that it is unclear whether request paths with CRLF followed by additional headers would be blocked by reverse proxies, or how they would be processed by Plack-based servers.

Join the discussion

CVE-2026-2328 is a high-severity vulnerability in WAGO Device Sphere that allows an unauthenticated remote attacker to perform path traversal due to improper input validation. This flaw enables access to backend components beyond their intended scope, potentially exposing sensitive information. The vulnerability does not require user interaction or privileges to exploit. No official patch or remediation guidance is currently provided by the vendor. There are no known exploits in the wild at this time.

Join the discussion
0

Ericsson Indoor Connect 8855 versions prior to 2025.Q3 contains an Improper Filtering of Special Elements vulnerability which, if exploited, can lead to unauthorized modification of certain information

Join the discussion

Showing 1 to 4 of 4 results

Filters:Tag: cwe-790
Page 1 of 1
OffSeq TrainingCredly Certified

Lead Pen Test Professional

Technical5-day eLearningPECB Accredited
View courses