CVE-2022-26649: CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') in Siemens SCALANCE X200-4P IRT
A vulnerability has been identified in SCALANCE X200-4P IRT (All versions < V5.5.2), SCALANCE X201-3P IRT (All versions < V5.5.2), SCALANCE X201-3P IRT PRO (All versions < V5.5.2), SCALANCE X202-2IRT (All versions < V5.5.2), SCALANCE X202-2IRT (All versions < V5.5.2), SCALANCE X202-2P IRT (All versions < V5.5.2), SCALANCE X202-2P IRT PRO (All versions < V5.5.2), SCALANCE X204-2 (All versions < V5.2.6), SCALANCE X204-2FM (All versions < V5.2.6), SCALANCE X204-2LD (All versions < V5.2.6), SCALANCE X204-2LD TS (All versions < V5.2.6), SCALANCE X204-2TS (All versions < V5.2.6), SCALANCE X204IRT (All versions < V5.5.2), SCALANCE X204IRT (All versions < V5.5.2), SCALANCE X204IRT PRO (All versions < V5.5.2), SCALANCE X206-1 (All versions < V5.2.6), SCALANCE X206-1LD (All versions < V5.2.6), SCALANCE X208 (All versions < V5.2.6), SCALANCE X208PRO (All versions < V5.2.6), SCALANCE X212-2 (All versions < V5.2.6), SCALANCE X212-2LD (All versions < V5.2.6), SCALANCE X216 (All versions < V5.2.6), SCALANCE X224 (All versions < V5.2.6), SCALANCE XF201-3P IRT (All versions < V5.5.2), SCALANCE XF202-2P IRT (All versions < V5.5.2), SCALANCE XF204 (All versions < V5.2.6), SCALANCE XF204-2 (All versions < V5.2.6), SCALANCE XF204-2BA IRT (All versions < V5.5.2), SCALANCE XF204IRT (All versions < V5.5.2), SCALANCE XF206-1 (All versions < V5.2.6), SCALANCE XF208 (All versions < V5.2.6). Affected devices do not properly validate the URI of incoming HTTP GET requests. This could allow an unauthenticated remote attacker to crash affected devices.
AI Analysis
Technical Summary
CVE-2022-26649 is a classic buffer overflow vulnerability (CWE-120) affecting multiple Siemens SCALANCE industrial network switches, specifically models in the X200 and XF200 series, including but not limited to SCALANCE X200-4P IRT, X201-3P IRT, X202-2IRT, X204-2, X206-1, X208, X212-2, X216, X224, and their PRO or IRT variants. The vulnerability exists in all firmware versions prior to V5.5.2 (or V5.2.6 for some models). The root cause is improper validation of the URI in incoming HTTP GET requests, where the device fails to check the size of input data before copying it into a buffer. This unchecked buffer copy can lead to a buffer overflow condition. An unauthenticated remote attacker can exploit this flaw by sending a specially crafted HTTP GET request to the affected device, causing it to crash (denial of service). Although no known exploits are reported in the wild, the vulnerability allows remote unauthenticated attackers to disrupt device availability without requiring user interaction or authentication. The affected devices are industrial-grade Ethernet switches widely used in critical infrastructure and industrial control systems (ICS) environments to provide real-time data communication and network segmentation. The vulnerability impacts the availability of these devices, potentially causing network outages or disruption of industrial processes relying on these switches. Siemens has released firmware updates (V5.5.2 or later) to address this issue, but no direct patch links were provided in the source information. The vulnerability was published on July 12, 2022, and is enriched by CISA, indicating its relevance to critical infrastructure security. Given the nature of the vulnerability, exploitation could be automated and remotely triggered, making it a significant risk for operational continuity in industrial environments.
Potential Impact
For European organizations, especially those operating in critical infrastructure sectors such as manufacturing, energy, transportation, and utilities, this vulnerability poses a significant risk to operational availability. SCALANCE switches are commonly deployed in industrial networks across Europe to ensure deterministic communication and network segmentation. A successful exploitation could lead to denial of service conditions, causing network outages, loss of real-time data exchange, and potential cascading failures in industrial control systems. This disruption could result in production downtime, safety risks, and financial losses. Additionally, the unauthenticated nature of the vulnerability means that attackers do not need credentials or insider access, increasing the attack surface. While no evidence of exploitation in the wild exists, the vulnerability could be leveraged by threat actors targeting European industrial environments, especially given the geopolitical focus on critical infrastructure resilience. The impact on confidentiality and integrity is limited, as the vulnerability primarily causes crashes rather than arbitrary code execution or data manipulation. However, availability impact alone in ICS contexts is critical due to the real-time and safety-sensitive nature of operations.
Mitigation Recommendations
1. Immediate firmware upgrade: Organizations should prioritize upgrading all affected Siemens SCALANCE devices to firmware versions V5.5.2 or later (or V5.2.6 or later for specific models) as provided by Siemens. 2. Network segmentation: Isolate management interfaces of SCALANCE switches from general enterprise networks and restrict access to trusted administrative hosts only. 3. Implement strict firewall rules: Block unauthorized HTTP GET requests to the management interfaces of these devices, especially from untrusted or external networks. 4. Monitor network traffic: Deploy intrusion detection systems (IDS) or anomaly detection tools to identify unusual HTTP requests targeting SCALANCE devices. 5. Disable unnecessary services: If HTTP management interfaces are not required, disable them to reduce the attack surface. 6. Incident response planning: Prepare for potential denial of service incidents by having failover or redundancy mechanisms in place for critical network paths. 7. Vendor coordination: Engage with Siemens support for official patches, advisories, and best practices specific to the affected models. 8. Asset inventory: Maintain an accurate inventory of all SCALANCE devices and their firmware versions to ensure timely patching and risk assessment.
Affected Countries
Germany, France, Italy, United Kingdom, Netherlands, Belgium, Poland, Sweden, Spain, Czech Republic
CVE-2022-26649: CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') in Siemens SCALANCE X200-4P IRT
Description
A vulnerability has been identified in SCALANCE X200-4P IRT (All versions < V5.5.2), SCALANCE X201-3P IRT (All versions < V5.5.2), SCALANCE X201-3P IRT PRO (All versions < V5.5.2), SCALANCE X202-2IRT (All versions < V5.5.2), SCALANCE X202-2IRT (All versions < V5.5.2), SCALANCE X202-2P IRT (All versions < V5.5.2), SCALANCE X202-2P IRT PRO (All versions < V5.5.2), SCALANCE X204-2 (All versions < V5.2.6), SCALANCE X204-2FM (All versions < V5.2.6), SCALANCE X204-2LD (All versions < V5.2.6), SCALANCE X204-2LD TS (All versions < V5.2.6), SCALANCE X204-2TS (All versions < V5.2.6), SCALANCE X204IRT (All versions < V5.5.2), SCALANCE X204IRT (All versions < V5.5.2), SCALANCE X204IRT PRO (All versions < V5.5.2), SCALANCE X206-1 (All versions < V5.2.6), SCALANCE X206-1LD (All versions < V5.2.6), SCALANCE X208 (All versions < V5.2.6), SCALANCE X208PRO (All versions < V5.2.6), SCALANCE X212-2 (All versions < V5.2.6), SCALANCE X212-2LD (All versions < V5.2.6), SCALANCE X216 (All versions < V5.2.6), SCALANCE X224 (All versions < V5.2.6), SCALANCE XF201-3P IRT (All versions < V5.5.2), SCALANCE XF202-2P IRT (All versions < V5.5.2), SCALANCE XF204 (All versions < V5.2.6), SCALANCE XF204-2 (All versions < V5.2.6), SCALANCE XF204-2BA IRT (All versions < V5.5.2), SCALANCE XF204IRT (All versions < V5.5.2), SCALANCE XF206-1 (All versions < V5.2.6), SCALANCE XF208 (All versions < V5.2.6). Affected devices do not properly validate the URI of incoming HTTP GET requests. This could allow an unauthenticated remote attacker to crash affected devices.
AI-Powered Analysis
Technical Analysis
CVE-2022-26649 is a classic buffer overflow vulnerability (CWE-120) affecting multiple Siemens SCALANCE industrial network switches, specifically models in the X200 and XF200 series, including but not limited to SCALANCE X200-4P IRT, X201-3P IRT, X202-2IRT, X204-2, X206-1, X208, X212-2, X216, X224, and their PRO or IRT variants. The vulnerability exists in all firmware versions prior to V5.5.2 (or V5.2.6 for some models). The root cause is improper validation of the URI in incoming HTTP GET requests, where the device fails to check the size of input data before copying it into a buffer. This unchecked buffer copy can lead to a buffer overflow condition. An unauthenticated remote attacker can exploit this flaw by sending a specially crafted HTTP GET request to the affected device, causing it to crash (denial of service). Although no known exploits are reported in the wild, the vulnerability allows remote unauthenticated attackers to disrupt device availability without requiring user interaction or authentication. The affected devices are industrial-grade Ethernet switches widely used in critical infrastructure and industrial control systems (ICS) environments to provide real-time data communication and network segmentation. The vulnerability impacts the availability of these devices, potentially causing network outages or disruption of industrial processes relying on these switches. Siemens has released firmware updates (V5.5.2 or later) to address this issue, but no direct patch links were provided in the source information. The vulnerability was published on July 12, 2022, and is enriched by CISA, indicating its relevance to critical infrastructure security. Given the nature of the vulnerability, exploitation could be automated and remotely triggered, making it a significant risk for operational continuity in industrial environments.
Potential Impact
For European organizations, especially those operating in critical infrastructure sectors such as manufacturing, energy, transportation, and utilities, this vulnerability poses a significant risk to operational availability. SCALANCE switches are commonly deployed in industrial networks across Europe to ensure deterministic communication and network segmentation. A successful exploitation could lead to denial of service conditions, causing network outages, loss of real-time data exchange, and potential cascading failures in industrial control systems. This disruption could result in production downtime, safety risks, and financial losses. Additionally, the unauthenticated nature of the vulnerability means that attackers do not need credentials or insider access, increasing the attack surface. While no evidence of exploitation in the wild exists, the vulnerability could be leveraged by threat actors targeting European industrial environments, especially given the geopolitical focus on critical infrastructure resilience. The impact on confidentiality and integrity is limited, as the vulnerability primarily causes crashes rather than arbitrary code execution or data manipulation. However, availability impact alone in ICS contexts is critical due to the real-time and safety-sensitive nature of operations.
Mitigation Recommendations
1. Immediate firmware upgrade: Organizations should prioritize upgrading all affected Siemens SCALANCE devices to firmware versions V5.5.2 or later (or V5.2.6 or later for specific models) as provided by Siemens. 2. Network segmentation: Isolate management interfaces of SCALANCE switches from general enterprise networks and restrict access to trusted administrative hosts only. 3. Implement strict firewall rules: Block unauthorized HTTP GET requests to the management interfaces of these devices, especially from untrusted or external networks. 4. Monitor network traffic: Deploy intrusion detection systems (IDS) or anomaly detection tools to identify unusual HTTP requests targeting SCALANCE devices. 5. Disable unnecessary services: If HTTP management interfaces are not required, disable them to reduce the attack surface. 6. Incident response planning: Prepare for potential denial of service incidents by having failover or redundancy mechanisms in place for critical network paths. 7. Vendor coordination: Engage with Siemens support for official patches, advisories, and best practices specific to the affected models. 8. Asset inventory: Maintain an accurate inventory of all SCALANCE devices and their firmware versions to ensure timely patching and risk assessment.
For access to advanced analysis and higher rate limits, contact root@offseq.com
Technical Details
- Data Version
- 5.1
- Assigner Short Name
- siemens
- Date Reserved
- 2022-03-07T00:00:00.000Z
- Cisa Enriched
- true
Threat ID: 682d984bc4522896dcbf8047
Added to database: 5/21/2025, 9:09:31 AM
Last enriched: 6/20/2025, 12:50:13 PM
Last updated: 8/18/2025, 2:36:08 AM
Views: 12
Related Threats
CVE-2025-9102: Improper Export of Android Application Components in 1&1 Mail & Media mail.com App
MediumCVE-2025-9101: Cross Site Scripting in zhenfeng13 My-Blog
MediumCVE-2025-9100: Authentication Bypass by Capture-replay in zhenfeng13 My-Blog
MediumCVE-2025-9099: Unrestricted Upload in Acrel Environmental Monitoring Cloud Platform
MediumCVE-2025-9098: Improper Export of Android Application Components in Elseplus File Recovery App
MediumActions
Updates to AI analysis are available only with a Pro account. Contact root@offseq.com for access.
External Links
Need enhanced features?
Contact root@offseq.com for Pro access with improved analysis and higher rate limits.