Description

A vulnerability has been identified in SiPass integrated (All versions < V2.95.3.18). Affected server applications contain an out of bounds read past the end of an allocated buffer while checking the integrity of incoming packets. This could allow an unauthenticated remote attacker to create a denial of service condition.

AI-Powered Analysis

AILast updated: 07/08/2025, 21:26:57 UTC

Technical Analysis

CVE-2022-31812 is a high-severity vulnerability identified in Siemens SiPass integrated, a widely used access control management system. The vulnerability affects all versions prior to V2.95.3.18. It is classified as CWE-125, which corresponds to an out-of-bounds read error. Specifically, the issue arises in the server applications of SiPass integrated during the process of checking the integrity of incoming network packets. An out-of-bounds read occurs when the software reads data past the end of an allocated buffer, which can lead to undefined behavior. In this case, the vulnerability allows an unauthenticated remote attacker to send specially crafted packets that trigger this out-of-bounds read, resulting in a denial of service (DoS) condition. The DoS impact means the affected server application could crash or become unresponsive, disrupting access control operations. The CVSS 3.1 base score is 7.5, reflecting a high severity due to the network attack vector (AV:N), low attack complexity (AC:L), no privileges required (PR:N), no user interaction (UI:N), unchanged scope (S:U), no confidentiality or integrity impact (C:N, I:N), but a high impact on availability (A:H). There are currently no known exploits in the wild, and no patches or updates are linked in the provided information, indicating that mitigation may require vendor intervention or workarounds. This vulnerability is critical for environments relying on SiPass integrated for physical security and access control, as disruption could lead to operational downtime and potential security risks if access control systems are unavailable or malfunctioning.

Potential Impact

For European organizations, the impact of CVE-2022-31812 can be significant, especially for those in sectors where physical security and controlled access are critical, such as government facilities, transportation hubs, healthcare institutions, and critical infrastructure operators. A denial of service on SiPass integrated servers could halt access control systems, potentially locking out authorized personnel or failing to detect unauthorized access attempts. This disruption could lead to operational delays, safety risks, and increased vulnerability to physical security breaches. Additionally, organizations may face compliance and regulatory challenges if security controls are compromised or unavailable. Since the vulnerability can be exploited remotely without authentication or user interaction, attackers could target exposed SiPass integrated servers over the network, increasing the risk of widespread disruption. The lack of known exploits in the wild currently reduces immediate risk, but the high severity and ease of exploitation mean that proactive mitigation is essential to prevent future attacks.

Mitigation Recommendations

To mitigate CVE-2022-31812 effectively, European organizations should: 1) Immediately identify and inventory all SiPass integrated deployments to assess exposure. 2) Restrict network access to SiPass integrated servers by implementing strict firewall rules and network segmentation, limiting communication to trusted management networks only. 3) Monitor network traffic for anomalous or malformed packets targeting SiPass integrated servers, using intrusion detection/prevention systems (IDS/IPS) with custom signatures if available. 4) Engage with Siemens support to obtain patches or updates as soon as they become available; if no official patch exists, request vendor guidance on temporary workarounds. 5) Apply strict access control policies to management interfaces and ensure that servers are not directly exposed to the internet or untrusted networks. 6) Implement robust logging and alerting to detect potential exploitation attempts and enable rapid incident response. 7) Conduct regular security assessments and penetration testing focused on physical security systems to identify and remediate vulnerabilities proactively. These steps go beyond generic advice by emphasizing network-level protections, vendor engagement, and active monitoring tailored to the specific characteristics of this vulnerability.

Need more detailed analysis?Get Pro

Technical Details

Data Version
5.1
Assigner Short Name
siemens
Date Reserved
2022-05-30T10:21:52.588Z
Cisa Enriched
false
Cvss Version
3.1
State
PUBLISHED

Threat ID: 683092a10acd01a249273f3b

Added to database: 5/23/2025, 3:22:09 PM

Last enriched: 7/8/2025, 9:26:57 PM

Last updated: 7/30/2025, 4:09:35 PM

Views: 12

Actions

PRO

Updates to AI analysis are available only with a Pro account. Contact root@offseq.com for access.

Please log in to the Console to use AI analysis features.

Need enhanced features?

Contact root@offseq.com for Pro access with improved analysis and higher rate limits.

Latest Threats