CVE-2022-34331: CWE-287 Improper Authentication in IBM Power FW
After performing a sequence of Power FW950, FW1010 maintenance operations a SRIOV network adapter can be improperly configured leading to desired VEPA configuration being disabled. IBM X-Force ID: 229695.
AI Analysis
Technical Summary
CVE-2022-34331 is a medium-severity vulnerability identified in IBM Power Firmware versions FW950 and FW1010. The vulnerability stems from improper authentication (CWE-287) during a sequence of maintenance operations on the Power FW platform. Specifically, after performing certain maintenance tasks, a Single Root I/O Virtualization (SR-IOV) network adapter can be misconfigured, resulting in the disabling of the desired Virtual Ethernet Port Aggregator (VEPA) configuration. VEPA is a network virtualization technology that enables efficient traffic management and isolation in virtualized environments. The improper configuration caused by this vulnerability can lead to reduced network segmentation and potentially allow unauthorized network traffic flows. The CVSS 3.1 base score is 5.5 (medium), with vector AV:N/AC:H/PR:H/UI:N/S:C/C:L/I:L/A:L, indicating that the vulnerability can be exploited remotely over the network but requires high attack complexity and privileges, with no user interaction needed. The impact affects confidentiality, integrity, and availability at a low level, but the scope is changed, meaning the vulnerability can affect resources beyond the initially vulnerable component. No known exploits are currently reported in the wild, and no patches are explicitly linked in the provided data, though IBM likely has firmware updates addressing this issue. This vulnerability is significant in environments using IBM Power systems with SR-IOV enabled network adapters, especially in data centers and cloud infrastructures relying on virtualization and network segmentation for security and performance.
Potential Impact
For European organizations, especially those operating data centers, cloud services, or enterprise IT environments utilizing IBM Power systems with SR-IOV network adapters, this vulnerability could lead to improper network adapter configurations that disable VEPA. This misconfiguration may weaken network isolation and segmentation, increasing the risk of lateral movement by attackers or unauthorized data access within virtualized environments. Although exploitation requires high privileges and complex attack conditions, insider threats or attackers who have already gained elevated access could leverage this vulnerability to degrade network security controls. The impact on confidentiality, integrity, and availability is low but non-negligible, as it could facilitate further attacks or data leakage in sensitive environments. Industries such as finance, telecommunications, and critical infrastructure in Europe that rely on IBM Power hardware for virtualization and networking could be particularly affected. Additionally, the vulnerability could disrupt network performance or cause configuration inconsistencies, impacting operational continuity.
Mitigation Recommendations
1. IBM Power system administrators should verify the firmware versions of their Power FW components and upgrade to the latest available firmware releases that address CVE-2022-34331. 2. Conduct thorough audits of SR-IOV network adapter configurations post-maintenance operations to ensure VEPA settings remain enabled and correctly configured. 3. Implement strict access controls and monitoring to limit and log privileged operations on IBM Power firmware to reduce the risk of improper maintenance sequences. 4. Employ network segmentation and micro-segmentation at higher layers to mitigate risks arising from potential VEPA misconfigurations. 5. Use automated configuration management and compliance tools to detect deviations in network adapter settings promptly. 6. Coordinate with IBM support to obtain any unpublished patches or recommended configuration guidelines. 7. Train IT staff on the importance of proper maintenance procedures and the risks associated with firmware misconfigurations in virtualized network environments. These steps go beyond generic patching advice by emphasizing configuration verification, access control, and operational best practices specific to IBM Power FW and SR-IOV networking.
Affected Countries
Germany, France, United Kingdom, Netherlands, Italy, Spain, Sweden, Belgium, Poland, Switzerland
CVE-2022-34331: CWE-287 Improper Authentication in IBM Power FW
Description
After performing a sequence of Power FW950, FW1010 maintenance operations a SRIOV network adapter can be improperly configured leading to desired VEPA configuration being disabled. IBM X-Force ID: 229695.
AI-Powered Analysis
Technical Analysis
CVE-2022-34331 is a medium-severity vulnerability identified in IBM Power Firmware versions FW950 and FW1010. The vulnerability stems from improper authentication (CWE-287) during a sequence of maintenance operations on the Power FW platform. Specifically, after performing certain maintenance tasks, a Single Root I/O Virtualization (SR-IOV) network adapter can be misconfigured, resulting in the disabling of the desired Virtual Ethernet Port Aggregator (VEPA) configuration. VEPA is a network virtualization technology that enables efficient traffic management and isolation in virtualized environments. The improper configuration caused by this vulnerability can lead to reduced network segmentation and potentially allow unauthorized network traffic flows. The CVSS 3.1 base score is 5.5 (medium), with vector AV:N/AC:H/PR:H/UI:N/S:C/C:L/I:L/A:L, indicating that the vulnerability can be exploited remotely over the network but requires high attack complexity and privileges, with no user interaction needed. The impact affects confidentiality, integrity, and availability at a low level, but the scope is changed, meaning the vulnerability can affect resources beyond the initially vulnerable component. No known exploits are currently reported in the wild, and no patches are explicitly linked in the provided data, though IBM likely has firmware updates addressing this issue. This vulnerability is significant in environments using IBM Power systems with SR-IOV enabled network adapters, especially in data centers and cloud infrastructures relying on virtualization and network segmentation for security and performance.
Potential Impact
For European organizations, especially those operating data centers, cloud services, or enterprise IT environments utilizing IBM Power systems with SR-IOV network adapters, this vulnerability could lead to improper network adapter configurations that disable VEPA. This misconfiguration may weaken network isolation and segmentation, increasing the risk of lateral movement by attackers or unauthorized data access within virtualized environments. Although exploitation requires high privileges and complex attack conditions, insider threats or attackers who have already gained elevated access could leverage this vulnerability to degrade network security controls. The impact on confidentiality, integrity, and availability is low but non-negligible, as it could facilitate further attacks or data leakage in sensitive environments. Industries such as finance, telecommunications, and critical infrastructure in Europe that rely on IBM Power hardware for virtualization and networking could be particularly affected. Additionally, the vulnerability could disrupt network performance or cause configuration inconsistencies, impacting operational continuity.
Mitigation Recommendations
1. IBM Power system administrators should verify the firmware versions of their Power FW components and upgrade to the latest available firmware releases that address CVE-2022-34331. 2. Conduct thorough audits of SR-IOV network adapter configurations post-maintenance operations to ensure VEPA settings remain enabled and correctly configured. 3. Implement strict access controls and monitoring to limit and log privileged operations on IBM Power firmware to reduce the risk of improper maintenance sequences. 4. Employ network segmentation and micro-segmentation at higher layers to mitigate risks arising from potential VEPA misconfigurations. 5. Use automated configuration management and compliance tools to detect deviations in network adapter settings promptly. 6. Coordinate with IBM support to obtain any unpublished patches or recommended configuration guidelines. 7. Train IT staff on the importance of proper maintenance procedures and the risks associated with firmware misconfigurations in virtualized network environments. These steps go beyond generic patching advice by emphasizing configuration verification, access control, and operational best practices specific to IBM Power FW and SR-IOV networking.
For access to advanced analysis and higher rate limits, contact root@offseq.com
Technical Details
- Data Version
- 5.1
- Assigner Short Name
- ibm
- Date Reserved
- 2022-06-22T19:42:48.457Z
- Cisa Enriched
- true
- Cvss Version
- 3.1
- State
- PUBLISHED
Threat ID: 682d9839c4522896dcbecd87
Added to database: 5/21/2025, 9:09:13 AM
Last enriched: 6/25/2025, 6:29:18 PM
Last updated: 7/31/2025, 5:31:31 PM
Views: 12
Related Threats
CVE-2025-9091: Hard-coded Credentials in Tenda AC20
LowCVE-2025-9090: Command Injection in Tenda AC20
MediumCVE-2025-9092: CWE-400 Uncontrolled Resource Consumption in Legion of the Bouncy Castle Inc. Bouncy Castle for Java - BC-FJA 2.1.0
LowCVE-2025-9089: Stack-based Buffer Overflow in Tenda AC20
HighCVE-2025-9088: Stack-based Buffer Overflow in Tenda AC20
HighActions
Updates to AI analysis are available only with a Pro account. Contact root@offseq.com for access.
External Links
Need enhanced features?
Contact root@offseq.com for Pro access with improved analysis and higher rate limits.