CVE-2022-38119: CWE-287 Improper Authentication in POWERCOM CO., LTD. UPSMON PRO
UPSMON Pro login function has insufficient authentication. An unauthenticated remote attacker can exploit this vulnerability to bypass authentication and get administrator privilege to access, control system or disrupt service.
AI Analysis
Technical Summary
CVE-2022-38119 is a critical authentication bypass vulnerability identified in the UPSMON PRO software version 2.57, developed by POWERCOM CO., LTD. The vulnerability is classified under CWE-287 (Improper Authentication), indicating that the login function of UPSMON PRO does not properly verify user credentials. This flaw allows an unauthenticated remote attacker to bypass the authentication mechanism entirely, granting them administrator-level privileges without any valid credentials. With such elevated access, the attacker can fully control the system, manipulate configurations, disrupt services, or potentially cause denial of service conditions. The vulnerability has a CVSS v3.1 base score of 9.8, reflecting its critical severity, with attack vector being network-based (AV:N), requiring no privileges (PR:N), no user interaction (UI:N), and impacting confidentiality, integrity, and availability at a high level (C:H/I:H/A:H). Although no public exploits have been reported in the wild yet, the ease of exploitation combined with the high impact makes this a significant risk for any organization using this software. UPSMON PRO is typically used for monitoring and managing uninterruptible power supply (UPS) systems, which are critical infrastructure components ensuring power continuity for IT systems and industrial equipment. Compromise of such management software could lead to power management failures, unexpected shutdowns, or manipulation of power supply parameters, potentially causing operational disruptions or damage to hardware.
Potential Impact
For European organizations, the impact of this vulnerability can be severe, especially for sectors relying heavily on uninterrupted power supply management such as data centers, healthcare facilities, manufacturing plants, and critical infrastructure operators. An attacker exploiting this vulnerability could gain full administrative control over UPSMON PRO systems, allowing them to disable or misconfigure UPS devices, leading to power outages or equipment damage. This could result in significant operational downtime, data loss, and safety hazards. Additionally, since UPSMON PRO often integrates with broader IT management and monitoring systems, the attacker could use this foothold to pivot into other parts of the network, escalating the impact to wider organizational systems. The confidentiality of sensitive operational data could also be compromised. Given the critical nature of power management in industrial and IT environments, this vulnerability poses a direct threat to business continuity and safety compliance within European organizations.
Mitigation Recommendations
1. Immediate upgrade or patching: Although no official patch links are provided, organizations should contact POWERCOM CO., LTD. for updates or patches addressing this vulnerability. 2. Network segmentation: Isolate UPSMON PRO management interfaces from general network access, restricting them to trusted administrative networks only. 3. Access control: Implement strict firewall rules and VPN access for remote management interfaces to limit exposure to the internet or untrusted networks. 4. Monitoring and logging: Enable detailed logging on UPSMON PRO systems and monitor for unusual login attempts or administrative actions that could indicate exploitation attempts. 5. Incident response readiness: Prepare and test incident response plans specifically for UPSMON PRO compromise scenarios, including backup power management strategies. 6. Vendor communication: Engage with POWERCOM for security advisories and consider alternative UPS management solutions if timely patches are unavailable. 7. Multi-factor authentication (MFA): If supported by UPSMON PRO or surrounding infrastructure, enforce MFA to add an additional layer of security, mitigating the risk of unauthorized access even if authentication bypass is attempted. 8. Regular vulnerability scanning: Include UPSMON PRO in routine vulnerability assessments to detect any unauthorized changes or exposures.
Affected Countries
Germany, France, United Kingdom, Italy, Spain, Netherlands, Poland, Belgium, Sweden, Finland
CVE-2022-38119: CWE-287 Improper Authentication in POWERCOM CO., LTD. UPSMON PRO
Description
UPSMON Pro login function has insufficient authentication. An unauthenticated remote attacker can exploit this vulnerability to bypass authentication and get administrator privilege to access, control system or disrupt service.
AI-Powered Analysis
Technical Analysis
CVE-2022-38119 is a critical authentication bypass vulnerability identified in the UPSMON PRO software version 2.57, developed by POWERCOM CO., LTD. The vulnerability is classified under CWE-287 (Improper Authentication), indicating that the login function of UPSMON PRO does not properly verify user credentials. This flaw allows an unauthenticated remote attacker to bypass the authentication mechanism entirely, granting them administrator-level privileges without any valid credentials. With such elevated access, the attacker can fully control the system, manipulate configurations, disrupt services, or potentially cause denial of service conditions. The vulnerability has a CVSS v3.1 base score of 9.8, reflecting its critical severity, with attack vector being network-based (AV:N), requiring no privileges (PR:N), no user interaction (UI:N), and impacting confidentiality, integrity, and availability at a high level (C:H/I:H/A:H). Although no public exploits have been reported in the wild yet, the ease of exploitation combined with the high impact makes this a significant risk for any organization using this software. UPSMON PRO is typically used for monitoring and managing uninterruptible power supply (UPS) systems, which are critical infrastructure components ensuring power continuity for IT systems and industrial equipment. Compromise of such management software could lead to power management failures, unexpected shutdowns, or manipulation of power supply parameters, potentially causing operational disruptions or damage to hardware.
Potential Impact
For European organizations, the impact of this vulnerability can be severe, especially for sectors relying heavily on uninterrupted power supply management such as data centers, healthcare facilities, manufacturing plants, and critical infrastructure operators. An attacker exploiting this vulnerability could gain full administrative control over UPSMON PRO systems, allowing them to disable or misconfigure UPS devices, leading to power outages or equipment damage. This could result in significant operational downtime, data loss, and safety hazards. Additionally, since UPSMON PRO often integrates with broader IT management and monitoring systems, the attacker could use this foothold to pivot into other parts of the network, escalating the impact to wider organizational systems. The confidentiality of sensitive operational data could also be compromised. Given the critical nature of power management in industrial and IT environments, this vulnerability poses a direct threat to business continuity and safety compliance within European organizations.
Mitigation Recommendations
1. Immediate upgrade or patching: Although no official patch links are provided, organizations should contact POWERCOM CO., LTD. for updates or patches addressing this vulnerability. 2. Network segmentation: Isolate UPSMON PRO management interfaces from general network access, restricting them to trusted administrative networks only. 3. Access control: Implement strict firewall rules and VPN access for remote management interfaces to limit exposure to the internet or untrusted networks. 4. Monitoring and logging: Enable detailed logging on UPSMON PRO systems and monitor for unusual login attempts or administrative actions that could indicate exploitation attempts. 5. Incident response readiness: Prepare and test incident response plans specifically for UPSMON PRO compromise scenarios, including backup power management strategies. 6. Vendor communication: Engage with POWERCOM for security advisories and consider alternative UPS management solutions if timely patches are unavailable. 7. Multi-factor authentication (MFA): If supported by UPSMON PRO or surrounding infrastructure, enforce MFA to add an additional layer of security, mitigating the risk of unauthorized access even if authentication bypass is attempted. 8. Regular vulnerability scanning: Include UPSMON PRO in routine vulnerability assessments to detect any unauthorized changes or exposures.
For access to advanced analysis and higher rate limits, contact root@offseq.com
Technical Details
- Data Version
- 5.1
- Assigner Short Name
- twcert
- Date Reserved
- 2022-08-10T00:00:00.000Z
- Cisa Enriched
- true
- Cvss Version
- 3.1
- State
- PUBLISHED
Threat ID: 682d9838c4522896dcbec555
Added to database: 5/21/2025, 9:09:12 AM
Last enriched: 6/25/2025, 9:42:42 PM
Last updated: 8/11/2025, 8:27:17 AM
Views: 12
Related Threats
CVE-2025-55716: CWE-862 Missing Authorization in VeronaLabs WP Statistics
MediumCVE-2025-55714: CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') in Crocoblock JetElements For Elementor
MediumCVE-2025-55713: CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') in CreativeThemes Blocksy
MediumCVE-2025-55712: CWE-862 Missing Authorization in POSIMYTH The Plus Addons for Elementor Page Builder Lite
MediumCVE-2025-55710: CWE-201 Insertion of Sensitive Information Into Sent Data in Steve Burge TaxoPress
MediumActions
Updates to AI analysis are available only with a Pro account. Contact root@offseq.com for access.
External Links
Need enhanced features?
Contact root@offseq.com for Pro access with improved analysis and higher rate limits.