CVE-2022-48669: Vulnerability in Linux Linux
In the Linux kernel, the following vulnerability has been resolved: powerpc/pseries: Fix potential memleak in papr_get_attr() `buf` is allocated in papr_get_attr(), and krealloc() of `buf` could fail. We need to free the original `buf` in the case of failure.
AI Analysis
Technical Summary
CVE-2022-48669 is a medium-severity vulnerability identified in the Linux kernel specifically affecting the powerpc/pseries architecture. The issue arises in the function papr_get_attr(), where a memory allocation buffer ('buf') is allocated and then potentially reallocated using krealloc(). If krealloc() fails, the original buffer is not freed, leading to a potential memory leak. While this vulnerability does not directly impact confidentiality or integrity, it affects availability by causing resource exhaustion over time if exploited or triggered repeatedly. The vulnerability requires local privileges (AV:L - local access), low attack complexity (AC:L), and privileges (PR:L) but does not require user interaction (UI:N). The scope is unchanged (S:U), and the impact is limited to availability (A:H), with no impact on confidentiality or integrity. The CVSS 3.1 base score is 5.5, indicating a medium severity. No known exploits are currently reported in the wild. The affected Linux kernel versions include specific commits identified by hashes, indicating that this is a recent fix. The vulnerability is specific to the PowerPC pseries platform, which is a less common architecture compared to x86 or ARM but is used in certain enterprise and specialized environments. The root cause is a failure to free memory upon krealloc() failure, which can lead to memory leaks and potential denial of service conditions if the system runs out of memory or suffers degraded performance due to memory exhaustion.
Potential Impact
For European organizations, the impact of CVE-2022-48669 is primarily related to system availability on affected PowerPC pseries Linux systems. Organizations using Linux servers or appliances based on PowerPC architecture, such as certain IBM Power Systems, could experience degraded performance or denial of service due to memory leaks if this vulnerability is exploited or triggered by malicious or faulty software. While the vulnerability does not allow privilege escalation, data leakage, or code execution, the availability impact could disrupt critical services, especially in environments where uptime and reliability are paramount, such as financial institutions, telecommunications, and industrial control systems. Given the niche architecture, the overall impact on the broader European IT infrastructure is limited but could be significant for organizations relying on PowerPC-based Linux systems. The lack of known exploits reduces immediate risk, but the vulnerability should be addressed promptly to prevent potential future exploitation or accidental system degradation.
Mitigation Recommendations
To mitigate CVE-2022-48669, European organizations should: 1) Apply the official Linux kernel patches that fix the memory leak in papr_get_attr() as soon as they become available from trusted sources or Linux distribution maintainers. 2) For systems where patching is not immediately feasible, monitor memory usage closely on PowerPC pseries Linux systems to detect abnormal memory consumption patterns that could indicate exploitation or triggering of the vulnerability. 3) Limit local access to affected systems by enforcing strict access controls and minimizing the number of users with local privileges, as exploitation requires local privileges. 4) Implement system resource limits (e.g., cgroups or ulimits) to prevent a single process from exhausting system memory. 5) Regularly update and audit software running on PowerPC Linux systems to reduce the risk of triggering this vulnerability through faulty or malicious code. 6) Engage with hardware and software vendors to ensure timely updates and support for PowerPC platforms. These steps go beyond generic advice by focusing on architecture-specific controls, proactive monitoring, and access restrictions tailored to the nature of this vulnerability.
Affected Countries
Germany, France, United Kingdom, Netherlands, Italy, Sweden
CVE-2022-48669: Vulnerability in Linux Linux
Description
In the Linux kernel, the following vulnerability has been resolved: powerpc/pseries: Fix potential memleak in papr_get_attr() `buf` is allocated in papr_get_attr(), and krealloc() of `buf` could fail. We need to free the original `buf` in the case of failure.
AI-Powered Analysis
Technical Analysis
CVE-2022-48669 is a medium-severity vulnerability identified in the Linux kernel specifically affecting the powerpc/pseries architecture. The issue arises in the function papr_get_attr(), where a memory allocation buffer ('buf') is allocated and then potentially reallocated using krealloc(). If krealloc() fails, the original buffer is not freed, leading to a potential memory leak. While this vulnerability does not directly impact confidentiality or integrity, it affects availability by causing resource exhaustion over time if exploited or triggered repeatedly. The vulnerability requires local privileges (AV:L - local access), low attack complexity (AC:L), and privileges (PR:L) but does not require user interaction (UI:N). The scope is unchanged (S:U), and the impact is limited to availability (A:H), with no impact on confidentiality or integrity. The CVSS 3.1 base score is 5.5, indicating a medium severity. No known exploits are currently reported in the wild. The affected Linux kernel versions include specific commits identified by hashes, indicating that this is a recent fix. The vulnerability is specific to the PowerPC pseries platform, which is a less common architecture compared to x86 or ARM but is used in certain enterprise and specialized environments. The root cause is a failure to free memory upon krealloc() failure, which can lead to memory leaks and potential denial of service conditions if the system runs out of memory or suffers degraded performance due to memory exhaustion.
Potential Impact
For European organizations, the impact of CVE-2022-48669 is primarily related to system availability on affected PowerPC pseries Linux systems. Organizations using Linux servers or appliances based on PowerPC architecture, such as certain IBM Power Systems, could experience degraded performance or denial of service due to memory leaks if this vulnerability is exploited or triggered by malicious or faulty software. While the vulnerability does not allow privilege escalation, data leakage, or code execution, the availability impact could disrupt critical services, especially in environments where uptime and reliability are paramount, such as financial institutions, telecommunications, and industrial control systems. Given the niche architecture, the overall impact on the broader European IT infrastructure is limited but could be significant for organizations relying on PowerPC-based Linux systems. The lack of known exploits reduces immediate risk, but the vulnerability should be addressed promptly to prevent potential future exploitation or accidental system degradation.
Mitigation Recommendations
To mitigate CVE-2022-48669, European organizations should: 1) Apply the official Linux kernel patches that fix the memory leak in papr_get_attr() as soon as they become available from trusted sources or Linux distribution maintainers. 2) For systems where patching is not immediately feasible, monitor memory usage closely on PowerPC pseries Linux systems to detect abnormal memory consumption patterns that could indicate exploitation or triggering of the vulnerability. 3) Limit local access to affected systems by enforcing strict access controls and minimizing the number of users with local privileges, as exploitation requires local privileges. 4) Implement system resource limits (e.g., cgroups or ulimits) to prevent a single process from exhausting system memory. 5) Regularly update and audit software running on PowerPC Linux systems to reduce the risk of triggering this vulnerability through faulty or malicious code. 6) Engage with hardware and software vendors to ensure timely updates and support for PowerPC platforms. These steps go beyond generic advice by focusing on architecture-specific controls, proactive monitoring, and access restrictions tailored to the nature of this vulnerability.
Affected Countries
For access to advanced analysis and higher rate limits, contact root@offseq.com
Technical Details
- Data Version
- 5.1
- Assigner Short Name
- Linux
- Date Reserved
- 2024-02-25T13:44:28.321Z
- Cisa Enriched
- true
- Cvss Version
- 3.1
- State
- PUBLISHED
Threat ID: 682d982ec4522896dcbe5e29
Added to database: 5/21/2025, 9:09:02 AM
Last enriched: 6/30/2025, 6:41:57 PM
Last updated: 7/25/2025, 10:32:24 PM
Views: 12
Related Threats
CVE-2025-8838: Improper Authentication in WinterChenS my-site
MediumCVE-2025-8837: Use After Free in JasPer
MediumCVE-2025-8661: Vulnerability in Broadcom Symantec PGP Encryption
MediumCVE-2025-8836: Reachable Assertion in JasPer
MediumCVE-2025-8747: CWE-502 Deserialization of Untrusted Data in Google Keras
HighActions
Updates to AI analysis are available only with a Pro account. Contact root@offseq.com for access.
External Links
Need enhanced features?
Contact root@offseq.com for Pro access with improved analysis and higher rate limits.