CVE-2023-45231: CWE-125 Out-of-bounds Read in TianoCore edk2
EDK2's Network Package is susceptible to an out-of-bounds read vulnerability when processing Neighbor Discovery Redirect message. This vulnerability can be exploited by an attacker to gain unauthorized access and potentially lead to a loss of Confidentiality.
AI Analysis
Technical Summary
CVE-2023-45231 is a security vulnerability classified as CWE-125 (Out-of-bounds Read) found in the TianoCore edk2 project, specifically within its Network Package. The vulnerability arises during the processing of IPv6 Neighbor Discovery Redirect messages, where the code improperly handles input data, leading to an out-of-bounds read condition. This flaw allows an attacker to remotely read memory locations beyond the allocated buffer without requiring any privileges or user interaction, solely by sending crafted Neighbor Discovery Redirect messages over the network. The vulnerability affects the edk2-stable202308 version of the firmware codebase, which is widely used in UEFI implementations across various hardware platforms. The CVSS v3.1 base score is 6.5, reflecting a medium severity level, with the vector indicating attack via adjacent network (AV:A), low attack complexity (AC:L), no privileges required (PR:N), no user interaction (UI:N), unchanged scope (S:U), and high confidentiality impact (C:H) but no impact on integrity or availability. Although no known exploits have been reported in the wild, the vulnerability could be leveraged to leak sensitive information from memory, potentially exposing cryptographic keys, credentials, or other confidential data stored in firmware memory. Given the critical role of UEFI firmware in system boot and security, such information disclosure could facilitate further attacks or bypass security controls. The lack of a patch link suggests that fixes may still be pending or in development, emphasizing the need for vigilance and interim mitigations.
Potential Impact
For European organizations, the primary impact of CVE-2023-45231 is the potential unauthorized disclosure of sensitive information stored in firmware memory, which could compromise confidentiality. This is particularly concerning for sectors relying heavily on secure boot and firmware integrity, such as finance, telecommunications, critical infrastructure, and government agencies. Exposure of cryptographic keys or security parameters could enable attackers to bypass secure boot mechanisms, implant persistent malware, or escalate privileges. Since the vulnerability can be exploited remotely over the network without authentication or user interaction, it increases the attack surface, especially in environments where IPv6 Neighbor Discovery traffic is permitted or unmanaged. The impact on availability and integrity is minimal, but the confidentiality breach could have cascading effects on organizational security posture. European organizations with legacy or unpatched UEFI implementations based on edk2 are at risk, and the lack of current exploits does not preclude future weaponization. The medium severity rating suggests a moderate but non-trivial risk that requires timely attention.
Mitigation Recommendations
1. Monitor TianoCore and vendor advisories closely for official patches addressing CVE-2023-45231 and apply them promptly once available. 2. Implement network-level controls to filter or block suspicious IPv6 Neighbor Discovery Redirect messages, especially from untrusted or external sources, to reduce exposure. 3. Employ firmware integrity verification tools and secure boot configurations to detect unauthorized firmware modifications that could exploit this vulnerability. 4. Conduct network segmentation to limit access to systems running vulnerable edk2 firmware, particularly restricting IPv6 traffic where feasible. 5. Engage with hardware and firmware vendors to confirm the presence of this vulnerability in their products and request timely updates. 6. Incorporate vulnerability scanning and firmware auditing into regular security assessments to identify affected devices. 7. Educate network administrators about the risks associated with Neighbor Discovery protocols and encourage monitoring for anomalous network traffic patterns. These measures go beyond generic advice by focusing on network protocol filtering, firmware integrity, and vendor coordination specific to the nature of this vulnerability.
Affected Countries
Germany, France, United Kingdom, Netherlands, Italy, Sweden
CVE-2023-45231: CWE-125 Out-of-bounds Read in TianoCore edk2
Description
EDK2's Network Package is susceptible to an out-of-bounds read vulnerability when processing Neighbor Discovery Redirect message. This vulnerability can be exploited by an attacker to gain unauthorized access and potentially lead to a loss of Confidentiality.
AI-Powered Analysis
Technical Analysis
CVE-2023-45231 is a security vulnerability classified as CWE-125 (Out-of-bounds Read) found in the TianoCore edk2 project, specifically within its Network Package. The vulnerability arises during the processing of IPv6 Neighbor Discovery Redirect messages, where the code improperly handles input data, leading to an out-of-bounds read condition. This flaw allows an attacker to remotely read memory locations beyond the allocated buffer without requiring any privileges or user interaction, solely by sending crafted Neighbor Discovery Redirect messages over the network. The vulnerability affects the edk2-stable202308 version of the firmware codebase, which is widely used in UEFI implementations across various hardware platforms. The CVSS v3.1 base score is 6.5, reflecting a medium severity level, with the vector indicating attack via adjacent network (AV:A), low attack complexity (AC:L), no privileges required (PR:N), no user interaction (UI:N), unchanged scope (S:U), and high confidentiality impact (C:H) but no impact on integrity or availability. Although no known exploits have been reported in the wild, the vulnerability could be leveraged to leak sensitive information from memory, potentially exposing cryptographic keys, credentials, or other confidential data stored in firmware memory. Given the critical role of UEFI firmware in system boot and security, such information disclosure could facilitate further attacks or bypass security controls. The lack of a patch link suggests that fixes may still be pending or in development, emphasizing the need for vigilance and interim mitigations.
Potential Impact
For European organizations, the primary impact of CVE-2023-45231 is the potential unauthorized disclosure of sensitive information stored in firmware memory, which could compromise confidentiality. This is particularly concerning for sectors relying heavily on secure boot and firmware integrity, such as finance, telecommunications, critical infrastructure, and government agencies. Exposure of cryptographic keys or security parameters could enable attackers to bypass secure boot mechanisms, implant persistent malware, or escalate privileges. Since the vulnerability can be exploited remotely over the network without authentication or user interaction, it increases the attack surface, especially in environments where IPv6 Neighbor Discovery traffic is permitted or unmanaged. The impact on availability and integrity is minimal, but the confidentiality breach could have cascading effects on organizational security posture. European organizations with legacy or unpatched UEFI implementations based on edk2 are at risk, and the lack of current exploits does not preclude future weaponization. The medium severity rating suggests a moderate but non-trivial risk that requires timely attention.
Mitigation Recommendations
1. Monitor TianoCore and vendor advisories closely for official patches addressing CVE-2023-45231 and apply them promptly once available. 2. Implement network-level controls to filter or block suspicious IPv6 Neighbor Discovery Redirect messages, especially from untrusted or external sources, to reduce exposure. 3. Employ firmware integrity verification tools and secure boot configurations to detect unauthorized firmware modifications that could exploit this vulnerability. 4. Conduct network segmentation to limit access to systems running vulnerable edk2 firmware, particularly restricting IPv6 traffic where feasible. 5. Engage with hardware and firmware vendors to confirm the presence of this vulnerability in their products and request timely updates. 6. Incorporate vulnerability scanning and firmware auditing into regular security assessments to identify affected devices. 7. Educate network administrators about the risks associated with Neighbor Discovery protocols and encourage monitoring for anomalous network traffic patterns. These measures go beyond generic advice by focusing on network protocol filtering, firmware integrity, and vendor coordination specific to the nature of this vulnerability.
Affected Countries
For access to advanced analysis and higher rate limits, contact root@offseq.com
Technical Details
- Data Version
- 5.2
- Assigner Short Name
- TianoCore
- Date Reserved
- 2023-10-05T20:48:19.877Z
- Cvss Version
- 3.1
- State
- PUBLISHED
Threat ID: 690904ac00ff46172d4a0d13
Added to database: 11/3/2025, 7:38:20 PM
Last enriched: 11/3/2025, 8:23:41 PM
Last updated: 11/5/2025, 1:27:46 PM
Views: 2
Community Reviews
0 reviewsCrowdsource mitigation strategies, share intel context, and vote on the most helpful responses. Sign in to add your voice and help keep defenders ahead.
Want to contribute mitigation steps or threat intel context? Sign in or create an account to join the community discussion.
Related Threats
U.S. Sanctions 10 North Korean Entities for Laundering $12.7M in Crypto and IT Fraud
MediumMysterious 'SmudgedSerpent' Hackers Target U.S. Policy Experts Amid Iran–Israel Tensions
MediumCVE-2025-12497: CWE-98 Improper Control of Filename for Include/Require Statement in PHP Program ('PHP Remote File Inclusion') in averta Premium Portfolio Features for Phlox theme
HighCVE-2025-11745: CWE-80 Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS) in spacetime Ad Inserter – Ad Manager & AdSense Ads
MediumNikkei Says 17,000 Impacted by Data Breach Stemming From Slack Account Hack
MediumActions
Updates to AI analysis require Pro Console access. Upgrade inside Console → Billing.
Need enhanced features?
Contact root@offseq.com for Pro access with improved analysis and higher rate limits.