CVE-2023-49124: CWE-125: Out-of-bounds Read in Siemens Solid Edge SE2023
A vulnerability has been identified in Solid Edge SE2023 (All versions < V223.0 Update 10). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.
AI Analysis
Technical Summary
CVE-2023-49124 is a high-severity vulnerability identified in Siemens Solid Edge SE2023, a widely used 3D CAD software application primarily employed in engineering and product design. The vulnerability is classified as CWE-125, an out-of-bounds read, which occurs when the software reads data beyond the allocated memory buffer while parsing specially crafted PAR files. This memory corruption flaw can lead to undefined behavior, including the potential for an attacker to execute arbitrary code within the context of the current process. The vulnerability affects all versions of Solid Edge SE2023 prior to V223.0 Update 10. Exploitation requires the victim to open or process a maliciously crafted PAR file, which triggers the out-of-bounds read. The CVSS v3.1 base score is 7.8, indicating a high severity level. The vector string (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C) reveals that the attack vector is local (AV:L), requiring low attack complexity (AC:L), no privileges (PR:N), but user interaction is required (UI:R). The scope remains unchanged (S:U), and the impact on confidentiality, integrity, and availability is high (C:H/I:H/A:H). The exploitability is partially functional (E:P), and the remediation level is official (RL:O) with confirmed report confidence (RC:C). No known exploits are currently observed in the wild. The vulnerability arises during the parsing of PAR files, which are project archive files used by Solid Edge to store design data. An attacker could craft a malicious PAR file and trick a user into opening it, resulting in memory corruption and potential code execution. This could lead to full compromise of the affected application and potentially the underlying system, depending on the privileges of the user running Solid Edge. Siemens has released an update (V223.0 Update 10) that addresses this issue, but no direct patch links were provided in the source information.
Potential Impact
For European organizations, especially those in manufacturing, automotive, aerospace, and industrial design sectors, this vulnerability poses a significant risk. Solid Edge is a critical tool in product lifecycle management and engineering workflows. Successful exploitation could lead to unauthorized code execution, enabling attackers to steal intellectual property, disrupt design processes, or implant persistent malware within engineering environments. Given the high confidentiality impact, sensitive design data could be exfiltrated, affecting competitive advantage and compliance with data protection regulations such as GDPR. The integrity and availability impacts could disrupt production timelines and cause financial losses. Since exploitation requires local access and user interaction, insider threats or targeted phishing campaigns delivering malicious PAR files are plausible attack vectors. The lack of known exploits in the wild suggests limited immediate threat, but the high severity and partial exploitability indicate that motivated attackers could develop working exploits. Organizations relying on Solid Edge SE2023 should consider this vulnerability a priority for remediation to avoid potential operational and reputational damage.
Mitigation Recommendations
1. Immediate upgrade to Siemens Solid Edge SE2023 V223.0 Update 10 or later, as this update addresses the vulnerability. 2. Implement strict file handling policies to restrict the opening of PAR files from untrusted or unknown sources. 3. Educate engineering and design teams about the risks of opening unsolicited or suspicious PAR files, emphasizing the need for caution and verification. 4. Employ endpoint protection solutions capable of detecting anomalous behavior related to memory corruption or code execution within Solid Edge processes. 5. Use application whitelisting and sandboxing techniques to limit the impact of potential exploitation by isolating Solid Edge execution environments. 6. Monitor network and system logs for unusual activity related to Solid Edge usage, including unexpected file access or process behavior. 7. Enforce the principle of least privilege for users running Solid Edge to minimize the potential impact of code execution. 8. Regularly review and update incident response plans to include scenarios involving engineering software compromise. 9. Coordinate with Siemens support channels for any additional advisories or patches as they become available.
Affected Countries
Germany, France, Italy, United Kingdom, Spain, Netherlands, Sweden, Belgium, Poland, Czech Republic
CVE-2023-49124: CWE-125: Out-of-bounds Read in Siemens Solid Edge SE2023
Description
A vulnerability has been identified in Solid Edge SE2023 (All versions < V223.0 Update 10). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.
AI-Powered Analysis
Technical Analysis
CVE-2023-49124 is a high-severity vulnerability identified in Siemens Solid Edge SE2023, a widely used 3D CAD software application primarily employed in engineering and product design. The vulnerability is classified as CWE-125, an out-of-bounds read, which occurs when the software reads data beyond the allocated memory buffer while parsing specially crafted PAR files. This memory corruption flaw can lead to undefined behavior, including the potential for an attacker to execute arbitrary code within the context of the current process. The vulnerability affects all versions of Solid Edge SE2023 prior to V223.0 Update 10. Exploitation requires the victim to open or process a maliciously crafted PAR file, which triggers the out-of-bounds read. The CVSS v3.1 base score is 7.8, indicating a high severity level. The vector string (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C) reveals that the attack vector is local (AV:L), requiring low attack complexity (AC:L), no privileges (PR:N), but user interaction is required (UI:R). The scope remains unchanged (S:U), and the impact on confidentiality, integrity, and availability is high (C:H/I:H/A:H). The exploitability is partially functional (E:P), and the remediation level is official (RL:O) with confirmed report confidence (RC:C). No known exploits are currently observed in the wild. The vulnerability arises during the parsing of PAR files, which are project archive files used by Solid Edge to store design data. An attacker could craft a malicious PAR file and trick a user into opening it, resulting in memory corruption and potential code execution. This could lead to full compromise of the affected application and potentially the underlying system, depending on the privileges of the user running Solid Edge. Siemens has released an update (V223.0 Update 10) that addresses this issue, but no direct patch links were provided in the source information.
Potential Impact
For European organizations, especially those in manufacturing, automotive, aerospace, and industrial design sectors, this vulnerability poses a significant risk. Solid Edge is a critical tool in product lifecycle management and engineering workflows. Successful exploitation could lead to unauthorized code execution, enabling attackers to steal intellectual property, disrupt design processes, or implant persistent malware within engineering environments. Given the high confidentiality impact, sensitive design data could be exfiltrated, affecting competitive advantage and compliance with data protection regulations such as GDPR. The integrity and availability impacts could disrupt production timelines and cause financial losses. Since exploitation requires local access and user interaction, insider threats or targeted phishing campaigns delivering malicious PAR files are plausible attack vectors. The lack of known exploits in the wild suggests limited immediate threat, but the high severity and partial exploitability indicate that motivated attackers could develop working exploits. Organizations relying on Solid Edge SE2023 should consider this vulnerability a priority for remediation to avoid potential operational and reputational damage.
Mitigation Recommendations
1. Immediate upgrade to Siemens Solid Edge SE2023 V223.0 Update 10 or later, as this update addresses the vulnerability. 2. Implement strict file handling policies to restrict the opening of PAR files from untrusted or unknown sources. 3. Educate engineering and design teams about the risks of opening unsolicited or suspicious PAR files, emphasizing the need for caution and verification. 4. Employ endpoint protection solutions capable of detecting anomalous behavior related to memory corruption or code execution within Solid Edge processes. 5. Use application whitelisting and sandboxing techniques to limit the impact of potential exploitation by isolating Solid Edge execution environments. 6. Monitor network and system logs for unusual activity related to Solid Edge usage, including unexpected file access or process behavior. 7. Enforce the principle of least privilege for users running Solid Edge to minimize the potential impact of code execution. 8. Regularly review and update incident response plans to include scenarios involving engineering software compromise. 9. Coordinate with Siemens support channels for any additional advisories or patches as they become available.
For access to advanced analysis and higher rate limits, contact root@offseq.com
Technical Details
- Data Version
- 5.1
- Assigner Short Name
- siemens
- Date Reserved
- 2023-11-22T14:43:13.524Z
- Cisa Enriched
- true
- Cvss Version
- 3.1
- State
- PUBLISHED
Threat ID: 682d983ac4522896dcbed118
Added to database: 5/21/2025, 9:09:14 AM
Last enriched: 6/25/2025, 4:41:22 PM
Last updated: 8/1/2025, 1:54:15 AM
Views: 10
Related Threats
CVE-2025-57703: CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') in Delta Electronics DIAEnergie
MediumCVE-2025-57702: CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') in Delta Electronics DIAEnergie
MediumCVE-2025-57701: CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') in Delta Electronics DIAEnergie
MediumCVE-2025-57700: CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') in Delta Electronics DIAEnergie
HighCVE-2025-9109: Observable Response Discrepancy in Portabilis i-Diario
MediumActions
Updates to AI analysis are available only with a Pro account. Contact root@offseq.com for access.
External Links
Need enhanced features?
Contact root@offseq.com for Pro access with improved analysis and higher rate limits.