Skip to main content

CVE-2023-49130: CWE-824: Access of Uninitialized Pointer in Siemens Solid Edge SE2023

High
VulnerabilityCVE-2023-49130cvecve-2023-49130cwe-824
Published: Tue Jan 09 2024 (01/09/2024, 10:00:04 UTC)
Source: CVE
Vendor/Project: Siemens
Product: Solid Edge SE2023

Description

A vulnerability has been identified in Solid Edge SE2023 (All versions < V223.0 Update 10). The affected application is vulnerable to uninitialized pointer access while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process.

AI-Powered Analysis

AILast updated: 06/25/2025, 16:39:55 UTC

Technical Analysis

CVE-2023-49130 is a high-severity vulnerability affecting Siemens Solid Edge SE2023 versions prior to V223.0 Update 10. The issue stems from an access of an uninitialized pointer during the parsing of specially crafted PAR files. This vulnerability is classified under CWE-824, which involves the use of uninitialized pointers leading to undefined behavior. In this context, an attacker can craft malicious PAR files that, when opened or processed by the vulnerable Solid Edge SE2023 application, trigger the uninitialized pointer access. This can result in arbitrary code execution within the context of the current process. The vulnerability requires local access (Attack Vector: Local) and user interaction (UI:R), meaning the user must open or otherwise interact with the malicious PAR file. No privileges are required to exploit this vulnerability (PR:N), and the attack complexity is low (AC:L). The impact on confidentiality, integrity, and availability is high, as successful exploitation allows execution of arbitrary code, potentially leading to full compromise of the affected application and possibly the underlying system. The vulnerability has not been reported as exploited in the wild yet, but the presence of a proof-of-concept or potential exploit is plausible given the partial exploitability rating (E:P). Siemens has not yet published a patch, so mitigation currently relies on workarounds and defensive measures. Solid Edge SE2023 is a widely used CAD software in engineering, manufacturing, and design sectors, often handling sensitive intellectual property and critical design data. The vulnerability's exploitation could lead to theft of proprietary designs, sabotage of engineering projects, or lateral movement within corporate networks if leveraged by attackers. Given the nature of the vulnerability, it is critical for organizations using Solid Edge SE2023 to prioritize updating to V223.0 Update 10 once available or apply interim mitigations to prevent malicious PAR files from being opened or processed.

Potential Impact

For European organizations, the impact of CVE-2023-49130 is significant, especially in industries reliant on Siemens Solid Edge SE2023 for product design and manufacturing such as automotive, aerospace, industrial machinery, and electronics. Compromise of design files can lead to intellectual property theft, loss of competitive advantage, and potential sabotage of production processes. The ability to execute arbitrary code could allow attackers to implant persistent malware, conduct espionage, or disrupt operations. Given the interconnected nature of manufacturing supply chains in Europe, a successful attack could propagate risks to partners and suppliers. Additionally, regulatory frameworks such as GDPR impose strict data protection requirements, and breaches involving sensitive design data could lead to legal and financial penalties. The requirement for user interaction means phishing or social engineering campaigns could be used to deliver malicious PAR files, increasing the risk vector. The lack of a current patch increases exposure, making timely mitigation critical to reduce risk.

Mitigation Recommendations

1. Restrict handling of PAR files: Implement strict policies to control the receipt and opening of PAR files, especially from untrusted or external sources. 2. User training: Educate users on the risks of opening unsolicited or suspicious PAR files and encourage verification of file sources. 3. Application sandboxing: Run Solid Edge SE2023 within a sandbox or isolated environment to limit the impact of potential code execution. 4. File scanning: Deploy advanced endpoint protection solutions capable of detecting malformed or malicious PAR files before they reach end users. 5. Network segmentation: Limit network access of systems running Solid Edge to reduce lateral movement opportunities. 6. Monitor for suspicious activity: Implement logging and monitoring to detect unusual behavior indicative of exploitation attempts. 7. Patch management: Plan for rapid deployment of the official Siemens update (V223.0 Update 10) once released. 8. Use application whitelisting to prevent unauthorized code execution within the Solid Edge environment. 9. Employ Data Loss Prevention (DLP) controls to monitor and prevent exfiltration of sensitive design data.

Need more detailed analysis?Get Pro

Technical Details

Data Version
5.1
Assigner Short Name
siemens
Date Reserved
2023-11-22T14:50:33.103Z
Cisa Enriched
true
Cvss Version
3.1
State
PUBLISHED

Threat ID: 682d983ac4522896dcbed142

Added to database: 5/21/2025, 9:09:14 AM

Last enriched: 6/25/2025, 4:39:55 PM

Last updated: 8/11/2025, 12:40:56 PM

Views: 22

Actions

PRO

Updates to AI analysis are available only with a Pro account. Contact root@offseq.com for access.

Please log in to the Console to use AI analysis features.

Need enhanced features?

Contact root@offseq.com for Pro access with improved analysis and higher rate limits.