CVE-2024-11797: CWE-787: Out-of-bounds Write in Fuji Electric Monitouch V-SFT

0
High
VulnerabilityCVE-2024-11797cvecve-2024-11797cwe-787
Published: Wed Nov 27 2024 (11/27/2024, 23:34:50 UTC)
Source: CVE Database V5
Vendor/Project: Fuji Electric
Product: Monitouch V-SFT

Description

CVE-2024-11797 is a high-severity remote code execution vulnerability in Fuji Electric Monitouch V-SFT version 6. 2. 3. 0. It arises from an out-of-bounds write during the parsing of V8 files due to improper validation of user-supplied data. Exploitation requires user interaction, such as opening a malicious file or visiting a crafted webpage. Successful exploitation allows attackers to execute arbitrary code with the privileges of the current process, impacting confidentiality, integrity, and availability. No known exploits are currently in the wild. The vulnerability is particularly relevant to industrial control systems using Monitouch V-SFT, which are common in manufacturing and critical infrastructure sectors. Mitigation involves applying patches when available, restricting file sources, and employing strict input validation and network segmentation.

AI-Powered Analysis

AILast updated: 02/26/2026, 05:41:49 UTC

Technical Analysis

CVE-2024-11797 is a remote code execution vulnerability identified in Fuji Electric's Monitouch V-SFT software, specifically version 6.2.3.0. The flaw is categorized under CWE-787, an out-of-bounds write vulnerability, which occurs during the parsing of V8 files. The root cause is insufficient validation of user-supplied data, allowing an attacker to write beyond the allocated buffer boundaries. This memory corruption can be exploited to execute arbitrary code within the context of the Monitouch V-SFT process. The attack vector requires user interaction, such as opening a maliciously crafted V8 file or visiting a malicious webpage that triggers the vulnerable parser. The vulnerability was assigned CVSS v3.0 base score of 7.8, indicating high severity, with attack vector local (AV:L), low attack complexity (AC:L), no privileges required (PR:N), user interaction required (UI:R), and high impact on confidentiality, integrity, and availability (C:H/I:H/A:H). Although no public exploits are known at this time, the potential for remote code execution in industrial control software poses a significant risk. Monitouch V-SFT is widely used in industrial automation environments, including manufacturing plants and critical infrastructure, making this vulnerability a concern for operational technology (OT) security. The vulnerability was reported by the Zero Day Initiative (ZDI) as ZDI-CAN-24662 and published on November 27, 2024. No official patches have been linked yet, emphasizing the need for proactive mitigation.

Potential Impact

The impact of CVE-2024-11797 is substantial for organizations relying on Fuji Electric Monitouch V-SFT in their industrial control systems. Successful exploitation allows attackers to execute arbitrary code, potentially leading to full system compromise. This can result in unauthorized control over industrial processes, data theft, sabotage, or disruption of critical infrastructure operations. The confidentiality, integrity, and availability of the affected systems are all at high risk, which could cause operational downtime, safety hazards, and financial losses. Given the nature of industrial environments, such a compromise could also have cascading effects on supply chains and public safety. The requirement for user interaction somewhat limits the attack surface but does not eliminate risk, especially in environments where users may open files from untrusted sources or access external web content. The absence of known exploits in the wild currently reduces immediate threat but does not preclude future exploitation attempts.

Mitigation Recommendations

1. Monitor Fuji Electric’s official channels for patches addressing CVE-2024-11797 and apply them promptly once available. 2. Implement strict file validation and scanning policies to prevent opening or processing untrusted or suspicious V8 files within Monitouch V-SFT environments. 3. Restrict user access to only trusted sources for files and web content, employing application whitelisting where feasible. 4. Segment industrial control networks from corporate and external networks to limit exposure and lateral movement in case of compromise. 5. Employ endpoint detection and response (EDR) solutions capable of detecting anomalous behavior indicative of exploitation attempts. 6. Conduct user awareness training focused on the risks of opening unsolicited files or visiting untrusted websites, especially in OT environments. 7. Regularly audit and monitor logs for unusual activity related to Monitouch V-SFT processes. 8. Consider deploying intrusion prevention systems (IPS) with signatures or heuristics targeting this vulnerability once available. 9. Maintain up-to-date backups of critical configurations and data to enable recovery in case of compromise.

Need more detailed analysis?Upgrade to Pro Console

Technical Details

Data Version
5.1
Assigner Short Name
zdi
Date Reserved
2024-11-26T16:02:21.244Z
Cvss Version
3.0
State
PUBLISHED

Threat ID: 699f6e1fb7ef31ef0b5965b6

Added to database: 2/25/2026, 9:48:15 PM

Last enriched: 2/26/2026, 5:41:49 AM

Last updated: 2/26/2026, 5:58:40 AM

Views: 1

Community Reviews

0 reviews

Crowdsource mitigation strategies, share intel context, and vote on the most helpful responses. Sign in to add your voice and help keep defenders ahead.

Sort by
Loading community insights…

Want to contribute mitigation steps or threat intel context? Sign in or create an account to join the community discussion.

Actions

PRO

Updates to AI analysis require Pro Console access. Upgrade inside Console → Billing.

Please log in to the Console to use AI analysis features.

Need more coverage?

Upgrade to Pro Console in Console -> Billing for AI refresh and higher limits.

For incident response and remediation, OffSeq services can help resolve threats faster.

Latest Threats