Skip to main content
Press slash or control plus K to focus the search. Use the arrow keys to navigate results and press enter to open a threat.
Reconnecting to live updates…

CVE-2024-12836: CWE-843: Access of Resource Using Incompatible Type ('Type Confusion') in Delta Electronics DRASimuCAD

0
High
VulnerabilityCVE-2024-12836cvecve-2024-12836cwe-843
Published: Mon Dec 30 2024 (12/30/2024, 16:50:06 UTC)
Source: CVE Database V5
Vendor/Project: Delta Electronics
Product: DRASimuCAD

Description

CVE-2024-12836 is a high-severity remote code execution vulnerability in Delta Electronics DRASimuCAD version 1. 02. It arises from a type confusion flaw in the parsing of STP files, allowing attackers to execute arbitrary code within the context of the affected process. Exploitation requires user interaction, such as opening a malicious file or visiting a crafted webpage. The vulnerability results from improper validation of user-supplied data leading to incompatible type access. While no known exploits are currently in the wild, the vulnerability poses significant risk due to its ability to compromise confidentiality, integrity, and availability. The CVSS score is 7. 8, reflecting its high impact and relatively low attack complexity. Organizations using DRASimuCAD should prioritize patching or applying mitigations to prevent exploitation. Countries with significant industrial automation and manufacturing sectors using Delta Electronics products are most at risk.

AI-Powered Analysis

AILast updated: 02/26/2026, 02:44:44 UTC

Technical Analysis

CVE-2024-12836 is a remote code execution vulnerability identified in Delta Electronics DRASimuCAD version 1.02, specifically within the STP file parsing functionality. The root cause is a type confusion condition (CWE-843), where the software incorrectly handles user-supplied data types during the parsing process. This flaw allows an attacker to craft malicious STP files that, when opened by a user, trigger the vulnerability and enable arbitrary code execution under the privileges of the DRASimuCAD process. Exploitation requires user interaction, such as opening a malicious file or visiting a malicious webpage that causes the application to parse the crafted STP file. The vulnerability does not require prior authentication and has a CVSS 3.0 base score of 7.8, indicating high severity with high impact on confidentiality, integrity, and availability. The attack vector is local (AV:L), meaning the attacker must have local access or trick the user into opening the malicious file. The vulnerability was reported by the Zero Day Initiative (ZDI) under ID ZDI-CAN-22450 and was publicly disclosed on December 30, 2024. No patches or known exploits are currently available, but the potential for remote code execution makes this a critical concern for organizations relying on DRASimuCAD for industrial automation and simulation tasks.

Potential Impact

The exploitation of CVE-2024-12836 can lead to full compromise of the affected system running DRASimuCAD, allowing attackers to execute arbitrary code with the same privileges as the application. This can result in unauthorized access to sensitive industrial design data, manipulation or destruction of simulation models, and potential disruption of industrial automation workflows. The confidentiality of proprietary designs and intellectual property is at risk, as is the integrity of simulation results critical for manufacturing processes. Availability may also be impacted if the attacker disrupts or disables the application. Given DRASimuCAD's role in industrial environments, successful exploitation could have downstream effects on production lines and operational technology systems, potentially causing financial losses and safety hazards. The requirement for user interaction limits the attack surface but does not eliminate risk, especially in environments where users may open files from untrusted sources.

Mitigation Recommendations

1. Immediately restrict access to DRASimuCAD version 1.02 installations and avoid opening STP files from untrusted or unknown sources. 2. Implement strict file validation and sandboxing measures to isolate the application and limit the impact of potential exploits. 3. Educate users on the risks of opening unsolicited or suspicious STP files and visiting untrusted websites. 4. Monitor network and endpoint activity for unusual behavior indicative of exploitation attempts, such as unexpected process executions or file modifications. 5. Coordinate with Delta Electronics for timely release and deployment of official patches or updates addressing this vulnerability. 6. Employ application whitelisting and endpoint detection and response (EDR) solutions to detect and block malicious payloads. 7. Use network segmentation to isolate systems running DRASimuCAD from critical operational technology networks to reduce lateral movement risk. 8. Regularly back up critical simulation data and configurations to enable recovery in case of compromise.

Need more detailed analysis?Upgrade to Pro Console

Technical Details

Data Version
5.1
Assigner Short Name
zdi
Date Reserved
2024-12-19T22:21:32.341Z
Cvss Version
3.0
State
PUBLISHED

Threat ID: 699f6e49b7ef31ef0b59c5a4

Added to database: 2/25/2026, 9:48:57 PM

Last enriched: 2/26/2026, 2:44:44 AM

Last updated: 2/26/2026, 6:33:55 AM

Views: 1

Community Reviews

0 reviews

Crowdsource mitigation strategies, share intel context, and vote on the most helpful responses. Sign in to add your voice and help keep defenders ahead.

Sort by
Loading community insights…

Want to contribute mitigation steps or threat intel context? Sign in or create an account to join the community discussion.

Actions

PRO

Updates to AI analysis require Pro Console access. Upgrade inside Console → Billing.

Please log in to the Console to use AI analysis features.

Need more coverage?

Upgrade to Pro Console in Console -> Billing for AI refresh and higher limits.

For incident response and remediation, OffSeq services can help resolve threats faster.

Latest Threats