CVE-2024-22900: n/a
Vinchin Backup & Recovery v7.2 was discovered to contain an authenticated remote code execution (RCE) vulnerability via the setNetworkCardInfo function.
AI Analysis
Technical Summary
CVE-2024-22900 is an authenticated remote code execution (RCE) vulnerability identified in Vinchin Backup & Recovery version 7.2. The vulnerability arises from improper handling within the setNetworkCardInfo function, which allows an attacker with authenticated access to execute arbitrary commands on the underlying operating system. The vulnerability is classified under CWE-77, indicating that it involves improper neutralization of special elements used in OS commands, leading to command injection. The CVSS v3.1 base score is 8.8, reflecting a high severity due to its network attack vector (AV:N), low attack complexity (AC:L), and the requirement of privileges (PR:L) but no user interaction (UI:N). Successful exploitation could compromise confidentiality, integrity, and availability of the backup system and potentially the broader network environment it protects. Although no public exploits have been reported yet, the vulnerability poses a significant risk to organizations relying on Vinchin Backup & Recovery for data protection. The lack of available patches at the time of disclosure further elevates the urgency for mitigation and monitoring.
Potential Impact
For European organizations, this vulnerability could lead to severe consequences including unauthorized access to backup data, manipulation or deletion of backups, and potential lateral movement within the network. Compromise of backup systems undermines disaster recovery capabilities, risking prolonged downtime and data loss. Critical sectors such as finance, healthcare, and government agencies that depend heavily on reliable backup solutions are particularly vulnerable. The ability to execute code remotely with low privileges but without user interaction increases the likelihood of targeted attacks or insider threats exploiting this flaw. Additionally, disruption or compromise of backup infrastructure could violate data protection regulations like GDPR, leading to legal and reputational damage.
Mitigation Recommendations
Until an official patch is released, European organizations should implement strict network segmentation to isolate backup management interfaces from general user networks and the internet. Enforce multi-factor authentication (MFA) and least privilege principles to limit access to the backup system. Monitor logs and network traffic for unusual commands or configuration changes related to network card settings. Disable or restrict the setNetworkCardInfo function if possible through configuration or application hardening. Regularly audit user accounts and permissions on the backup system to detect unauthorized access. Prepare incident response plans specific to backup infrastructure compromise. Engage with Vinchin support for updates on patches and advisories. Consider deploying intrusion detection/prevention systems (IDS/IPS) tuned to detect command injection patterns.
Affected Countries
Germany, France, United Kingdom, Netherlands, Italy, Spain, Poland, Sweden
CVE-2024-22900: n/a
Description
Vinchin Backup & Recovery v7.2 was discovered to contain an authenticated remote code execution (RCE) vulnerability via the setNetworkCardInfo function.
AI-Powered Analysis
Technical Analysis
CVE-2024-22900 is an authenticated remote code execution (RCE) vulnerability identified in Vinchin Backup & Recovery version 7.2. The vulnerability arises from improper handling within the setNetworkCardInfo function, which allows an attacker with authenticated access to execute arbitrary commands on the underlying operating system. The vulnerability is classified under CWE-77, indicating that it involves improper neutralization of special elements used in OS commands, leading to command injection. The CVSS v3.1 base score is 8.8, reflecting a high severity due to its network attack vector (AV:N), low attack complexity (AC:L), and the requirement of privileges (PR:L) but no user interaction (UI:N). Successful exploitation could compromise confidentiality, integrity, and availability of the backup system and potentially the broader network environment it protects. Although no public exploits have been reported yet, the vulnerability poses a significant risk to organizations relying on Vinchin Backup & Recovery for data protection. The lack of available patches at the time of disclosure further elevates the urgency for mitigation and monitoring.
Potential Impact
For European organizations, this vulnerability could lead to severe consequences including unauthorized access to backup data, manipulation or deletion of backups, and potential lateral movement within the network. Compromise of backup systems undermines disaster recovery capabilities, risking prolonged downtime and data loss. Critical sectors such as finance, healthcare, and government agencies that depend heavily on reliable backup solutions are particularly vulnerable. The ability to execute code remotely with low privileges but without user interaction increases the likelihood of targeted attacks or insider threats exploiting this flaw. Additionally, disruption or compromise of backup infrastructure could violate data protection regulations like GDPR, leading to legal and reputational damage.
Mitigation Recommendations
Until an official patch is released, European organizations should implement strict network segmentation to isolate backup management interfaces from general user networks and the internet. Enforce multi-factor authentication (MFA) and least privilege principles to limit access to the backup system. Monitor logs and network traffic for unusual commands or configuration changes related to network card settings. Disable or restrict the setNetworkCardInfo function if possible through configuration or application hardening. Regularly audit user accounts and permissions on the backup system to detect unauthorized access. Prepare incident response plans specific to backup infrastructure compromise. Engage with Vinchin support for updates on patches and advisories. Consider deploying intrusion detection/prevention systems (IDS/IPS) tuned to detect command injection patterns.
Affected Countries
For access to advanced analysis and higher rate limits, contact root@offseq.com
Technical Details
- Data Version
- 5.1
- Assigner Short Name
- mitre
- Date Reserved
- 2024-01-11T00:00:00.000Z
- Cvss Version
- 3.1
- State
- PUBLISHED
Threat ID: 6843500671f4d251b5de40b8
Added to database: 6/6/2025, 8:31:02 PM
Last enriched: 11/4/2025, 11:59:46 PM
Last updated: 12/3/2025, 5:58:35 PM
Views: 52
Community Reviews
0 reviewsCrowdsource mitigation strategies, share intel context, and vote on the most helpful responses. Sign in to add your voice and help keep defenders ahead.
Want to contribute mitigation steps or threat intel context? Sign in or create an account to join the community discussion.
Actions
Updates to AI analysis require Pro Console access. Upgrade inside Console → Billing.
Need enhanced features?
Contact root@offseq.com for Pro access with improved analysis and higher rate limits.