CVE-2024-33698: CWE-122: Heap-based Buffer Overflow in Siemens Opcenter Quality

0
Critical
VulnerabilityCVE-2024-33698cvecve-2024-33698cwe-122
Published: Tue Sep 10 2024 (09/10/2024, 09:36:31 UTC)
Source: CVE Database V5
Vendor/Project: Siemens
Product: Opcenter Quality

Description

A vulnerability has been identified in Opcenter Quality (All versions < V2406), Opcenter RDnL (All versions < V2410), SIMATIC PCS neo V4.0 (All versions), SIMATIC PCS neo V4.1 (All versions < V4.1 Update 2), SIMATIC PCS neo V5.0 (All versions < V5.0 Update 1), SINEC NMS (All versions), SINEMA Remote Connect Client (All versions < V3.2 SP3), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 5), Totally Integrated Automation Portal (TIA Portal) V19 (All versions < V19 Update 3). Affected products contain a heap-based buffer overflow vulnerability in the integrated UMC component. This could allow an unauthenticated remote attacker to execute arbitrary code.

AI-Powered Analysis

AILast updated: 10/14/2025, 09:35:28 UTC

Technical Analysis

CVE-2024-33698 is a heap-based buffer overflow vulnerability identified in Siemens' Opcenter Quality, Opcenter RDnL, SIMATIC PCS neo (various versions), SINEC NMS, SINEMA Remote Connect Client, and multiple versions of the Totally Integrated Automation Portal (TIA Portal). The vulnerability resides in the integrated UMC component, which is part of these industrial and manufacturing software suites. Due to improper handling of heap memory, an attacker can craft malicious network packets that trigger the overflow, enabling arbitrary code execution remotely without requiring authentication or user interaction. The vulnerability affects all versions prior to specific updates (e.g., Opcenter Quality versions before V2406, SIMATIC PCS neo versions before V5.0 Update 1, TIA Portal versions before V19 Update 3, etc.). The CVSS v3.1 score is 9.8 (critical), reflecting the vulnerability's ease of exploitation (network vector, no privileges required), and its severe impact on confidentiality, integrity, and availability. Siemens has not yet released patches at the time of this report, and no public exploits have been observed. The affected products are widely used in industrial automation, manufacturing execution systems (MES), and process control environments, making this vulnerability a significant threat to operational technology (OT) environments.

Potential Impact

The impact of CVE-2024-33698 on European organizations is substantial, especially those in manufacturing, industrial automation, and critical infrastructure sectors that rely heavily on Siemens software products. Exploitation could lead to full system compromise, allowing attackers to execute arbitrary code, disrupt manufacturing processes, manipulate quality control data, or cause denial of service. This could result in operational downtime, safety hazards, intellectual property theft, and financial losses. Given the criticality of industrial control systems in Europe’s economy and infrastructure, successful exploitation could have cascading effects on supply chains and national security. The unauthenticated remote nature of the vulnerability increases the risk of widespread attacks, including potential ransomware or sabotage campaigns targeting European industrial environments.

Mitigation Recommendations

1. Immediate deployment of Siemens-provided patches or updates once available is paramount. 2. Until patches are released, isolate affected systems from untrusted networks by implementing strict network segmentation and firewall rules to restrict access to the UMC component. 3. Employ intrusion detection and prevention systems (IDS/IPS) to monitor for anomalous traffic patterns targeting the affected products. 4. Conduct thorough vulnerability scans across the environment to identify all instances of the affected Siemens software versions. 5. Limit exposure by disabling or restricting remote access to affected components where feasible. 6. Implement application whitelisting and endpoint protection to detect and block unauthorized code execution. 7. Maintain robust backup and recovery procedures to minimize operational impact in case of compromise. 8. Train OT and IT staff to recognize signs of exploitation and respond promptly. 9. Collaborate with Siemens support and subscribe to their security advisories for timely updates.

Need more detailed analysis?Get Pro

Technical Details

Data Version
5.1
Assigner Short Name
siemens
Date Reserved
2024-04-26T12:32:09.263Z
Cvss Version
3.1
State
PUBLISHED

Threat ID: 68ee16327eab8b438c025da5

Added to database: 10/14/2025, 9:21:54 AM

Last enriched: 10/14/2025, 9:35:28 AM

Last updated: 10/14/2025, 2:37:05 PM

Views: 4

Community Reviews

0 reviews

Crowdsource mitigation strategies, share intel context, and vote on the most helpful responses. Sign in to add your voice and help keep defenders ahead.

Sort by
Loading community insights…

Want to contribute mitigation steps or threat intel context? Sign in or create an account to join the community discussion.

Actions

PRO

Updates to AI analysis require Pro Console access. Upgrade inside Console → Billing.

Please log in to the Console to use AI analysis features.

Need enhanced features?

Contact root@offseq.com for Pro access with improved analysis and higher rate limits.

Latest Threats