CVE-2024-39868: CWE-425: Direct Request ('Forced Browsing') in Siemens SINEMA Remote Connect Server
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2 SP1). Affected devices do not properly validate the authentication when performing certain actions in the web interface allowing an unauthenticated attacker to access and edit VxLAN configuration information of networks for which they have no privileges.
AI Analysis
Technical Summary
CVE-2024-39868 is a high-severity vulnerability affecting Siemens SINEMA Remote Connect Server versions prior to 3.2 SP1. The vulnerability is classified under CWE-425, which corresponds to Direct Request or Forced Browsing attacks. Specifically, the issue arises because the affected versions do not properly validate authentication when certain actions are performed via the web interface. This flaw allows an unauthenticated attacker to bypass access controls and directly request sensitive operations related to VxLAN (Virtual Extensible LAN) configuration. As a result, the attacker can access and modify VxLAN network configurations for which they have no privileges. VxLAN is a network virtualization technology used to extend Layer 2 networks over Layer 3 infrastructure, commonly employed in industrial and enterprise environments to segment and isolate network traffic. The vulnerability's CVSS 3.1 base score is 7.6, indicating a high severity level. The vector string (CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:H/E:P/RL:O/RC:C) reveals that the attack can be performed remotely over the network with low attack complexity, requires low privileges (PR:L), and no user interaction. The scope is unchanged, but the impact on availability is high, with limited confidentiality and integrity impacts. Exploitation could lead to significant disruption of network segmentation and connectivity, potentially affecting industrial control systems and critical infrastructure relying on SINEMA Remote Connect Server for secure remote access and network management. No known exploits are currently reported in the wild, and no official patches are linked yet, but the vulnerability is publicly disclosed and enriched by CISA, indicating the need for immediate attention.
Potential Impact
For European organizations, especially those in industrial sectors such as manufacturing, energy, utilities, and critical infrastructure, this vulnerability poses a significant risk. SINEMA Remote Connect Server is widely used in industrial automation environments to manage secure remote connections and network configurations. An attacker exploiting this vulnerability could alter VxLAN configurations, potentially disrupting network segmentation and isolation, which are critical for protecting operational technology (OT) environments. This could lead to unauthorized access to sensitive industrial networks, manipulation of network traffic, and denial of service conditions. The impact extends to the integrity and availability of industrial control systems, potentially causing operational downtime, safety hazards, and financial losses. Given the reliance on Siemens products across Europe and the critical nature of affected networks, exploitation could also have cascading effects on supply chains and national infrastructure resilience. The vulnerability’s ability to be exploited remotely without user interaction and with low privileges increases the risk of widespread attacks if not mitigated promptly.
Mitigation Recommendations
1. Immediate upgrade to Siemens SINEMA Remote Connect Server version 3.2 SP1 or later once available, as this version addresses the vulnerability. 2. Until patches are released, restrict network access to the SINEMA Remote Connect Server web interface by implementing strict firewall rules and network segmentation to limit exposure only to trusted management networks. 3. Employ multi-factor authentication (MFA) and strong access control policies for all users with privileges on the SINEMA Remote Connect Server to reduce the risk posed by low-privilege exploitation. 4. Monitor network traffic and server logs for unusual or unauthorized access attempts, especially those targeting VxLAN configuration endpoints. 5. Conduct regular vulnerability assessments and penetration testing focused on industrial network management systems to identify and remediate similar access control weaknesses. 6. Collaborate with Siemens support and subscribe to security advisories to receive timely updates and patches. 7. Implement compensating controls such as network anomaly detection systems and intrusion prevention systems tailored for industrial environments to detect and block forced browsing attempts.
Affected Countries
Germany, France, Italy, Spain, United Kingdom, Netherlands, Belgium, Sweden, Poland, Czech Republic
CVE-2024-39868: CWE-425: Direct Request ('Forced Browsing') in Siemens SINEMA Remote Connect Server
Description
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2 SP1). Affected devices do not properly validate the authentication when performing certain actions in the web interface allowing an unauthenticated attacker to access and edit VxLAN configuration information of networks for which they have no privileges.
AI-Powered Analysis
Technical Analysis
CVE-2024-39868 is a high-severity vulnerability affecting Siemens SINEMA Remote Connect Server versions prior to 3.2 SP1. The vulnerability is classified under CWE-425, which corresponds to Direct Request or Forced Browsing attacks. Specifically, the issue arises because the affected versions do not properly validate authentication when certain actions are performed via the web interface. This flaw allows an unauthenticated attacker to bypass access controls and directly request sensitive operations related to VxLAN (Virtual Extensible LAN) configuration. As a result, the attacker can access and modify VxLAN network configurations for which they have no privileges. VxLAN is a network virtualization technology used to extend Layer 2 networks over Layer 3 infrastructure, commonly employed in industrial and enterprise environments to segment and isolate network traffic. The vulnerability's CVSS 3.1 base score is 7.6, indicating a high severity level. The vector string (CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:H/E:P/RL:O/RC:C) reveals that the attack can be performed remotely over the network with low attack complexity, requires low privileges (PR:L), and no user interaction. The scope is unchanged, but the impact on availability is high, with limited confidentiality and integrity impacts. Exploitation could lead to significant disruption of network segmentation and connectivity, potentially affecting industrial control systems and critical infrastructure relying on SINEMA Remote Connect Server for secure remote access and network management. No known exploits are currently reported in the wild, and no official patches are linked yet, but the vulnerability is publicly disclosed and enriched by CISA, indicating the need for immediate attention.
Potential Impact
For European organizations, especially those in industrial sectors such as manufacturing, energy, utilities, and critical infrastructure, this vulnerability poses a significant risk. SINEMA Remote Connect Server is widely used in industrial automation environments to manage secure remote connections and network configurations. An attacker exploiting this vulnerability could alter VxLAN configurations, potentially disrupting network segmentation and isolation, which are critical for protecting operational technology (OT) environments. This could lead to unauthorized access to sensitive industrial networks, manipulation of network traffic, and denial of service conditions. The impact extends to the integrity and availability of industrial control systems, potentially causing operational downtime, safety hazards, and financial losses. Given the reliance on Siemens products across Europe and the critical nature of affected networks, exploitation could also have cascading effects on supply chains and national infrastructure resilience. The vulnerability’s ability to be exploited remotely without user interaction and with low privileges increases the risk of widespread attacks if not mitigated promptly.
Mitigation Recommendations
1. Immediate upgrade to Siemens SINEMA Remote Connect Server version 3.2 SP1 or later once available, as this version addresses the vulnerability. 2. Until patches are released, restrict network access to the SINEMA Remote Connect Server web interface by implementing strict firewall rules and network segmentation to limit exposure only to trusted management networks. 3. Employ multi-factor authentication (MFA) and strong access control policies for all users with privileges on the SINEMA Remote Connect Server to reduce the risk posed by low-privilege exploitation. 4. Monitor network traffic and server logs for unusual or unauthorized access attempts, especially those targeting VxLAN configuration endpoints. 5. Conduct regular vulnerability assessments and penetration testing focused on industrial network management systems to identify and remediate similar access control weaknesses. 6. Collaborate with Siemens support and subscribe to security advisories to receive timely updates and patches. 7. Implement compensating controls such as network anomaly detection systems and intrusion prevention systems tailored for industrial environments to detect and block forced browsing attempts.
For access to advanced analysis and higher rate limits, contact root@offseq.com
Technical Details
- Data Version
- 5.1
- Assigner Short Name
- siemens
- Date Reserved
- 2024-07-01T13:05:40.287Z
- Cisa Enriched
- true
- Cvss Version
- 3.1
- State
- PUBLISHED
Threat ID: 682d983ac4522896dcbed220
Added to database: 5/21/2025, 9:09:14 AM
Last enriched: 6/25/2025, 3:47:38 PM
Last updated: 7/26/2025, 12:00:33 PM
Views: 10
Related Threats
CVE-2025-8820: Stack-based Buffer Overflow in Linksys RE6250
HighCVE-2025-8819: Stack-based Buffer Overflow in Linksys RE6250
HighCVE-2025-8818: OS Command Injection in Linksys RE6250
MediumCVE-2025-8816: Stack-based Buffer Overflow in Linksys RE6250
HighCVE-2025-8815: Path Traversal in 猫宁i Morning
MediumActions
Updates to AI analysis are available only with a Pro account. Contact root@offseq.com for access.
External Links
Need enhanced features?
Contact root@offseq.com for Pro access with improved analysis and higher rate limits.