CVE-2024-40582 is a high-severity vulnerability in Pentaminds CuroVMS v2. 0. 1 involving the exposure of sensitive information without requiring authentication or user interaction. The flaw allows remote attackers to access confidential data over the network with low attack complexity. Although no known exploits are currently active in the wild, the vulnerability poses a significant confidentiality risk. There is no patch currently available, increasing the urgency for mitigation. Organizations using CuroVMS v2. 0. 1 should prioritize protective measures to prevent unauthorized data disclosure. The vulnerability is classified under CWE-312, indicating improper protection of sensitive information.
AI Analysis
Technical Summary
CVE-2024-40582 is a vulnerability identified in Pentaminds CuroVMS version 2.0.1 that results in the exposure of sensitive information. The vulnerability is categorized under CWE-312, which pertains to the improper protection of sensitive data, such as credentials, keys, or personal information, that should otherwise be confidential. According to the CVSS v3.1 vector (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N), the attack can be performed remotely over the network without any privileges or user interaction, and it has a low attack complexity. The impact is high on confidentiality, meaning attackers can access sensitive data, but there is no impact on integrity or availability. The vulnerability does not require authentication, making it easier for attackers to exploit. No patches or fixes have been published yet, and no known exploits have been observed in the wild. The lack of a patch increases the risk for organizations using this software, as attackers may develop exploits in the future. The vulnerability could allow attackers to gather sensitive information that may facilitate further attacks or unauthorized access to systems. Pentaminds CuroVMS is a video management system, often used in security and surveillance contexts, which may contain sensitive operational data or credentials. The exposure of such information could compromise security monitoring and incident response capabilities.
Potential Impact
The primary impact of CVE-2024-40582 is the unauthorized disclosure of sensitive information, which can lead to significant confidentiality breaches. Organizations relying on Pentaminds CuroVMS v2.0.1 may have critical surveillance data, credentials, or configuration details exposed to remote attackers. This exposure can undermine trust in security infrastructure, facilitate lateral movement within networks, or enable attackers to bypass security controls. Although the vulnerability does not affect system integrity or availability directly, the leaked information could be leveraged for more damaging attacks, including privilege escalation or targeted intrusions. The ease of exploitation (no authentication or user interaction required) increases the risk of widespread exploitation once an exploit becomes available. The absence of patches means organizations must rely on mitigations and monitoring, increasing operational overhead and risk. Industries such as government, critical infrastructure, transportation, and large enterprises using CuroVMS for surveillance are particularly vulnerable to espionage or sabotage attempts. The reputational damage and potential regulatory consequences from data exposure could also be significant.
Mitigation Recommendations
Until an official patch is released, organizations should implement network-level protections such as restricting access to the CuroVMS management interfaces using firewalls or VPNs to trusted IP addresses only. Employ network segmentation to isolate the CuroVMS servers from general user networks and the internet. Monitor network traffic for unusual access patterns or data exfiltration attempts related to the CuroVMS system. Conduct regular audits of system logs and access records to detect unauthorized access. If possible, disable or limit services that expose sensitive information externally. Employ intrusion detection/prevention systems (IDS/IPS) tuned to detect reconnaissance or exploitation attempts targeting CuroVMS. Engage with Pentaminds support or vendor channels to obtain updates on patch availability and apply them promptly once released. Consider compensating controls such as encrypting sensitive data at rest and in transit within the CuroVMS environment. Train security teams to recognize indicators of compromise related to this vulnerability. Maintain an incident response plan specific to potential exploitation scenarios involving surveillance systems.
Affected Countries
United States, Germany, United Kingdom, France, Canada, Australia, Japan, South Korea, India, United Arab Emirates, Singapore
CVE-2024-40582: n/a
Description
CVE-2024-40582 is a high-severity vulnerability in Pentaminds CuroVMS v2. 0. 1 involving the exposure of sensitive information without requiring authentication or user interaction. The flaw allows remote attackers to access confidential data over the network with low attack complexity. Although no known exploits are currently active in the wild, the vulnerability poses a significant confidentiality risk. There is no patch currently available, increasing the urgency for mitigation. Organizations using CuroVMS v2. 0. 1 should prioritize protective measures to prevent unauthorized data disclosure. The vulnerability is classified under CWE-312, indicating improper protection of sensitive information.
AI-Powered Analysis
Technical Analysis
CVE-2024-40582 is a vulnerability identified in Pentaminds CuroVMS version 2.0.1 that results in the exposure of sensitive information. The vulnerability is categorized under CWE-312, which pertains to the improper protection of sensitive data, such as credentials, keys, or personal information, that should otherwise be confidential. According to the CVSS v3.1 vector (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N), the attack can be performed remotely over the network without any privileges or user interaction, and it has a low attack complexity. The impact is high on confidentiality, meaning attackers can access sensitive data, but there is no impact on integrity or availability. The vulnerability does not require authentication, making it easier for attackers to exploit. No patches or fixes have been published yet, and no known exploits have been observed in the wild. The lack of a patch increases the risk for organizations using this software, as attackers may develop exploits in the future. The vulnerability could allow attackers to gather sensitive information that may facilitate further attacks or unauthorized access to systems. Pentaminds CuroVMS is a video management system, often used in security and surveillance contexts, which may contain sensitive operational data or credentials. The exposure of such information could compromise security monitoring and incident response capabilities.
Potential Impact
The primary impact of CVE-2024-40582 is the unauthorized disclosure of sensitive information, which can lead to significant confidentiality breaches. Organizations relying on Pentaminds CuroVMS v2.0.1 may have critical surveillance data, credentials, or configuration details exposed to remote attackers. This exposure can undermine trust in security infrastructure, facilitate lateral movement within networks, or enable attackers to bypass security controls. Although the vulnerability does not affect system integrity or availability directly, the leaked information could be leveraged for more damaging attacks, including privilege escalation or targeted intrusions. The ease of exploitation (no authentication or user interaction required) increases the risk of widespread exploitation once an exploit becomes available. The absence of patches means organizations must rely on mitigations and monitoring, increasing operational overhead and risk. Industries such as government, critical infrastructure, transportation, and large enterprises using CuroVMS for surveillance are particularly vulnerable to espionage or sabotage attempts. The reputational damage and potential regulatory consequences from data exposure could also be significant.
Mitigation Recommendations
Until an official patch is released, organizations should implement network-level protections such as restricting access to the CuroVMS management interfaces using firewalls or VPNs to trusted IP addresses only. Employ network segmentation to isolate the CuroVMS servers from general user networks and the internet. Monitor network traffic for unusual access patterns or data exfiltration attempts related to the CuroVMS system. Conduct regular audits of system logs and access records to detect unauthorized access. If possible, disable or limit services that expose sensitive information externally. Employ intrusion detection/prevention systems (IDS/IPS) tuned to detect reconnaissance or exploitation attempts targeting CuroVMS. Engage with Pentaminds support or vendor channels to obtain updates on patch availability and apply them promptly once released. Consider compensating controls such as encrypting sensitive data at rest and in transit within the CuroVMS environment. Train security teams to recognize indicators of compromise related to this vulnerability. Maintain an incident response plan specific to potential exploitation scenarios involving surveillance systems.
Technical Details
- Data Version
- 5.1
- Assigner Short Name
- mitre
- Date Reserved
- 2024-07-05T00:00:00.000Z
- Cvss Version
- 3.1
- State
- PUBLISHED
Threat ID: 699f6cafb7ef31ef0b568058
Added to database: 2/25/2026, 9:42:07 PM
Last enriched: 2/26/2026, 6:50:21 AM
Last updated: 2/26/2026, 9:41:32 AM
Views: 1
Community Reviews
0 reviewsCrowdsource mitigation strategies, share intel context, and vote on the most helpful responses. Sign in to add your voice and help keep defenders ahead.
Want to contribute mitigation steps or threat intel context? Sign in or create an account to join the community discussion.
Related Threats
CVE-2026-28138: Deserialization of Untrusted Data in Stylemix uListing
HighCVE-2026-28136: Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') in VeronaLabs WP SMS
HighCVE-2026-28132: Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS) in villatheme WooCommerce Photo Reviews
HighCVE-2026-28131: Insertion of Sensitive Information Into Sent Data in WPVibes Elementor Addon Elements
HighCVE-2026-28083: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') in UX-themes Flatsome
HighActions
Updates to AI analysis require Pro Console access. Upgrade inside Console → Billing.
Need more coverage?
Upgrade to Pro Console in Console -> Billing for AI refresh and higher limits.
For incident response and remediation, OffSeq services can help resolve threats faster.