Skip to main content

CVE-2024-46899: CWE-1392 Use of Default Credentials in Hitachi Hitachi Ops Center Common Services

Medium
Published: Tue Apr 22 2025 (04/22/2025, 04:12:56 UTC)
Source: CVE
Vendor/Project: Hitachi
Product: Hitachi Ops Center Common Services

Description

Hitachi Ops Center Common Services within Hitachi Ops Center Analyzer viewpoint OVF contains an authentication credentials leakage vulnerability.This issue affects Hitachi Ops Center Common Services: from 10.0.0-00 before 11.0.0-04; Hitachi Ops Center Analyzer viewpoint OVF: from 10.0.0-00 before 11.0.0-04.

AI-Powered Analysis

AILast updated: 06/21/2025, 17:10:28 UTC

Technical Analysis

CVE-2024-46899 identifies a vulnerability in Hitachi Ops Center Common Services and Hitachi Ops Center Analyzer viewpoint OVF, specifically versions from 10.0.0-00 before 11.0.0-04. The vulnerability is categorized under CWE-1392, which relates to the use of default credentials. This means that the affected software components ship with default authentication credentials that are either hardcoded or not properly changed during deployment, leading to an authentication credentials leakage vulnerability. An attacker with network access to the affected service could potentially leverage these default credentials to gain unauthorized access to the system. Hitachi Ops Center is a management and analytics platform used primarily for storage infrastructure monitoring and management, often deployed in enterprise data centers. The vulnerability arises because the default credentials are either documented or easily guessable, and the system does not enforce mandatory credential changes upon installation or first use. This can lead to unauthorized access to sensitive management interfaces, potentially exposing configuration data, operational analytics, or enabling further lateral movement within the network. The vulnerability does not require user interaction but does require network access to the affected service. No known exploits are currently reported in the wild, and no patches or updates have been explicitly linked in the provided data, though newer versions (11.0.0-04 and later) are not affected, indicating that remediation involves upgrading to a fixed version. The vulnerability impacts confidentiality and integrity primarily, as unauthorized access could lead to data exposure or unauthorized configuration changes. Availability impact is less direct but could occur if attackers disrupt management services. The ease of exploitation is moderate, given that default credentials are often well-known or easily discovered, and no additional authentication bypass is required beyond these credentials.

Potential Impact

For European organizations, particularly those operating large-scale data centers or storage infrastructures using Hitachi Ops Center products, this vulnerability poses a significant risk. Unauthorized access to management services could lead to exposure of sensitive operational data, configuration details, and potentially allow attackers to manipulate storage resources or analytics data. This could disrupt business continuity, compromise data integrity, and lead to compliance violations under regulations such as GDPR if personal data is indirectly exposed. The risk is heightened in environments where network segmentation is weak, allowing attackers to reach management interfaces from less secure network zones. Additionally, organizations relying on Hitachi Ops Center for critical infrastructure monitoring may face operational risks if attackers leverage this access for further attacks or sabotage. Given the medium severity rating and the absence of known exploits, the immediate risk is moderate but could escalate if exploit code becomes publicly available. European organizations with stringent regulatory requirements and high-value data assets should prioritize addressing this vulnerability to avoid potential reputational and financial damage.

Mitigation Recommendations

1. Immediate upgrade to Hitachi Ops Center Common Services and Analyzer viewpoint OVF version 11.0.0-04 or later, where the vulnerability is resolved. 2. If upgrading is not immediately feasible, implement strict network segmentation and firewall rules to restrict access to the affected management interfaces only to trusted administrative hosts and networks. 3. Manually change any default credentials on existing deployments to strong, unique passwords following best practices for credential management. 4. Conduct a thorough audit of all Hitachi Ops Center instances to identify any deployments running vulnerable versions and verify credential configurations. 5. Implement multi-factor authentication (MFA) where possible on management interfaces to add an additional layer of security beyond passwords. 6. Monitor network traffic and logs for any unauthorized access attempts or unusual activity targeting the Hitachi Ops Center services. 7. Educate IT and security teams about the risks of default credentials and enforce policies that prohibit their use in production environments. 8. Engage with Hitachi support to obtain any interim patches or guidance if available and stay updated on official advisories.

Need more detailed analysis?Get Pro

Technical Details

Data Version
5.1
Assigner Short Name
Hitachi
Date Reserved
2024-10-22T04:20:15.324Z
Cisa Enriched
true

Threat ID: 682d984ac4522896dcbf7696

Added to database: 5/21/2025, 9:09:30 AM

Last enriched: 6/21/2025, 5:10:28 PM

Last updated: 8/15/2025, 11:32:55 AM

Views: 18

Actions

PRO

Updates to AI analysis are available only with a Pro account. Contact root@offseq.com for access.

Please log in to the Console to use AI analysis features.

Need enhanced features?

Contact root@offseq.com for Pro access with improved analysis and higher rate limits.

Latest Threats