CVE-2024-47563: CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') in Siemens SINEC Security Monitor

0
Medium
VulnerabilityCVE-2024-47563cvecve-2024-47563cwe-22
Published: Tue Oct 08 2024 (10/08/2024, 08:40:52 UTC)
Source: CVE Database V5
Vendor/Project: Siemens
Product: SINEC Security Monitor

Description

A vulnerability has been identified in SINEC Security Monitor (All versions < V4.9.0). The affected application does not properly validate a file path that is supplied to an endpoint intended to create CSR files. This could allow an unauthenticated remote attacker to create files in writable directories outside the intended location and thus compromise integrity of files in those writable directories.

AI-Powered Analysis

AILast updated: 03/10/2026, 17:50:40 UTC

Technical Analysis

CVE-2024-47563 is a CWE-22 path traversal vulnerability found in Siemens SINEC Security Monitor, a network security monitoring tool used primarily in industrial and critical infrastructure environments. The flaw exists in the file path validation logic of an endpoint designed to create Certificate Signing Request (CSR) files. Specifically, the application fails to properly restrict the pathname supplied by an unauthenticated remote attacker, allowing directory traversal sequences (e.g., ../) to escape the intended directory. This enables the attacker to create arbitrary files in any writable directory accessible by the application process. While the vulnerability does not disclose sensitive information or cause denial of service, it compromises file integrity by allowing unauthorized file creation, which could be leveraged for further attacks such as planting malicious files or disrupting system operations. The vulnerability affects all versions prior to 4.9.0. The CVSS 3.1 base score is 5.3, reflecting network attack vector, low attack complexity, no privileges required, no user interaction, and partial impact on integrity only. No public exploits or active exploitation have been reported yet. Siemens has acknowledged the issue but has not released a patch at the time of this report.

Potential Impact

The primary impact of this vulnerability is the potential compromise of file integrity within affected systems. An attacker can create or overwrite files in writable directories outside the intended CSR file location, which may allow insertion of malicious scripts, configuration files, or other artifacts that could disrupt system operations or facilitate privilege escalation and lateral movement. Although confidentiality and availability are not directly affected, the integrity breach can undermine trust in system components and potentially lead to more severe attacks if combined with other vulnerabilities. Organizations relying on Siemens SINEC Security Monitor in industrial control systems, manufacturing, energy, or critical infrastructure sectors could face operational risks and regulatory compliance issues if exploited. The lack of authentication requirement increases the risk of remote exploitation by unauthenticated attackers scanning for vulnerable endpoints.

Mitigation Recommendations

Organizations should immediately assess their deployment of Siemens SINEC Security Monitor and identify versions prior to 4.9.0. Since no official patch is currently available, the following mitigations are recommended: 1) Restrict network access to the vulnerable endpoint by implementing firewall rules or network segmentation to limit exposure to trusted management networks only. 2) Monitor logs for suspicious requests containing directory traversal patterns targeting the CSR creation endpoint. 3) Employ application-layer filtering or web application firewalls (WAFs) to detect and block path traversal attempts. 4) Harden file system permissions to minimize writable directories accessible by the application process, reducing the impact of unauthorized file creation. 5) Prepare for rapid deployment of the official patch once released by Siemens. 6) Conduct regular integrity checks on critical files and directories to detect unauthorized modifications. 7) Educate security teams about this vulnerability to improve detection and response capabilities.

Pro Console: star threats, build custom feeds, automate alerts via Slack, email & webhooks.Upgrade to Pro

Technical Details

Data Version
5.2
Assigner Short Name
siemens
Date Reserved
2024-09-27T10:57:37.067Z
Cvss Version
3.1
State
PUBLISHED

Threat ID: 69b05637ea502d3aa87d7c1c

Added to database: 3/10/2026, 5:34:47 PM

Last enriched: 3/10/2026, 5:50:40 PM

Last updated: 3/11/2026, 10:31:47 AM

Views: 4

Community Reviews

0 reviews

Crowdsource mitigation strategies, share intel context, and vote on the most helpful responses. Sign in to add your voice and help keep defenders ahead.

Sort by
Loading community insights…

Want to contribute mitigation steps or threat intel context? Sign in or create an account to join the community discussion.

Actions

PRO

Updates to AI analysis require Pro Console access. Upgrade inside Console → Billing.

Please log in to the Console to use AI analysis features.

Need more coverage?

Upgrade to Pro Console in Console -> Billing for AI refresh and higher limits.

For incident response and remediation, OffSeq services can help resolve threats faster.

Latest Threats

Breach by OffSeqOFFSEQFRIENDS — 25% OFF

Check if your credentials are on the dark web

Instant breach scanning across billions of leaked records. Free tier available.

Scan now
OffSeq TrainingCredly Certified

Lead Pen Test Professional

Technical5-day eLearningPECB Accredited
View courses