Skip to main content
Press slash or control plus K to focus the search. Use the arrow keys to navigate results and press enter to open a threat.
Reconnecting to live updates…

CVE-2024-48830: CWE-77: Improper Neutralization of Special Elements used in a Command ('Command Injection') in Dell SmartFabric OS10 Software

0
High
VulnerabilityCVE-2024-48830cvecve-2024-48830cwe-77
Published: Mon Mar 17 2025 (03/17/2025, 16:56:13 UTC)
Source: CVE Database V5
Vendor/Project: Dell
Product: SmartFabric OS10 Software

Description

Dell SmartFabric OS10 Software, version(s) 10.5.4.x, 10.5.5.x, 10.5.6.x, 10.6.0.x, contain(s) an Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Command execution.

AI-Powered Analysis

AILast updated: 02/26/2026, 21:18:27 UTC

Technical Analysis

CVE-2024-48830 is a command injection vulnerability classified under CWE-77, affecting Dell SmartFabric OS10 Software versions 10.5.4.x through 10.6.0.x. The flaw arises from improper neutralization of special elements used in command inputs, allowing an attacker with low privileges and local access to execute arbitrary system commands. This vulnerability does not require user interaction but does require the attacker to have local access to the device, which could be through physical presence or compromised credentials with limited privileges. Successful exploitation can lead to full compromise of the device, enabling attackers to manipulate network configurations, disrupt operations, or pivot to other network segments. The CVSS v3.1 score is 7.8, indicating high severity, with impacts on confidentiality, integrity, and availability. Although no public exploits are currently known, the nature of the vulnerability and affected product—critical network infrastructure software—make it a significant risk. Dell has not yet published patches, so mitigation currently relies on access restrictions and monitoring. The vulnerability highlights the importance of input validation and command sanitization in network operating systems.

Potential Impact

The impact of CVE-2024-48830 is substantial for organizations relying on Dell SmartFabric OS10 Software in their network infrastructure. Exploitation can lead to unauthorized command execution, potentially allowing attackers to alter network configurations, disable security controls, intercept or redirect traffic, and cause denial of service. This compromises the confidentiality, integrity, and availability of network operations. Given that SmartFabric OS10 is used in data centers, enterprise networks, and service provider environments, a successful attack could disrupt critical business functions, cause data breaches, and facilitate lateral movement within networks. The requirement for local access limits remote exploitation but does not eliminate risk, especially in environments where insider threats or compromised credentials exist. The absence of known exploits currently provides a window for proactive defense, but the high severity score demands urgent attention to prevent future attacks.

Mitigation Recommendations

Until official patches are released by Dell, organizations should implement strict access control measures to limit local access to devices running SmartFabric OS10. This includes enforcing strong authentication mechanisms, restricting physical access to network hardware, and monitoring for unusual local login attempts. Network segmentation should be employed to isolate management interfaces from general user access. Administrators should audit and harden device configurations, disable unnecessary services, and apply principle of least privilege to all accounts. Continuous monitoring and logging of command executions and system behavior can help detect attempted exploitation. Once patches become available, organizations must prioritize timely deployment. Additionally, conducting regular vulnerability assessments and penetration testing on network infrastructure can help identify and remediate related weaknesses proactively.

Need more detailed analysis?Upgrade to Pro Console

Technical Details

Data Version
5.2
Assigner Short Name
dell
Date Reserved
2024-10-08T16:18:11.122Z
Cvss Version
3.1
State
PUBLISHED

Threat ID: 69a0a44285912abc71d630db

Added to database: 2/26/2026, 7:51:30 PM

Last enriched: 2/26/2026, 9:18:27 PM

Last updated: 2/26/2026, 11:16:38 PM

Views: 4

Community Reviews

0 reviews

Crowdsource mitigation strategies, share intel context, and vote on the most helpful responses. Sign in to add your voice and help keep defenders ahead.

Sort by
Loading community insights…

Want to contribute mitigation steps or threat intel context? Sign in or create an account to join the community discussion.

Actions

PRO

Updates to AI analysis require Pro Console access. Upgrade inside Console → Billing.

Please log in to the Console to use AI analysis features.

Need more coverage?

Upgrade to Pro Console in Console -> Billing for AI refresh and higher limits.

For incident response and remediation, OffSeq services can help resolve threats faster.

Latest Threats

Breach by OffSeqOFFSEQFRIENDS — 25% OFF

Check if your credentials are on the dark web

Instant breach scanning across billions of leaked records. Free tier available.

Scan now
OffSeq TrainingCredly Certified

Lead Pen Test Professional

Technical5-day eLearningPECB Accredited
View courses