Skip to main content
Press slash or control plus K to focus the search. Use the arrow keys to navigate results and press enter to open a threat.
Reconnecting to live updates…

CVE-2024-49564: CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') in Dell Unity

0
High
VulnerabilityCVE-2024-49564cvecve-2024-49564cwe-78
Published: Fri Mar 28 2025 (03/28/2025, 01:31:59 UTC)
Source: CVE Database V5
Vendor/Project: Dell
Product: Unity

Description

Dell Unity, version(s) 5.4 and prior, contain(s) an Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to execution of arbitrary operating system commands with root privileges and elevation of privileges.

AI-Powered Analysis

AILast updated: 02/26/2026, 21:17:35 UTC

Technical Analysis

CVE-2024-49564 is an OS command injection vulnerability identified in Dell Unity storage systems, specifically versions 5.4 and prior. The root cause is improper neutralization of special elements used in OS commands, classified under CWE-78. This flaw allows a low-privileged attacker who has local access to the system to inject and execute arbitrary operating system commands with root-level privileges, effectively enabling privilege escalation and full system compromise. The vulnerability does not require user interaction and has a CVSS v3.1 base score of 7.8, indicating high severity. The attack vector is local (AV:L), with low attack complexity (AC:L) and low privileges required (PR:L). The scope remains unchanged (S:U), but the impact on confidentiality, integrity, and availability is high (C:H/I:H/A:H). While no public exploits have been reported yet, the potential for exploitation is significant due to the severity and ease of exploitation once local access is obtained. The vulnerability affects Dell Unity storage arrays, which are widely used in enterprise data centers for storage management and data protection. Exploitation could lead to unauthorized data access, data manipulation, or disruption of storage services, severely impacting organizational operations.

Potential Impact

The impact of CVE-2024-49564 is substantial for organizations using Dell Unity storage systems. Successful exploitation allows attackers to gain root privileges, leading to complete control over the affected storage system. This can result in unauthorized access to sensitive data, data corruption or deletion, and disruption of critical storage services. Enterprises relying on Dell Unity for data storage and backup could face significant operational downtime, data breaches, and compliance violations. The elevated privileges also enable attackers to pivot to other parts of the network, increasing the risk of broader compromise. Given the critical role of storage infrastructure in IT environments, the vulnerability poses a high risk to confidentiality, integrity, and availability of enterprise data. Organizations in sectors such as finance, healthcare, government, and telecommunications, where data integrity and availability are paramount, are particularly at risk.

Mitigation Recommendations

To mitigate CVE-2024-49564, organizations should implement the following specific measures: 1) Immediately restrict local access to Dell Unity systems to trusted administrators only, using strong authentication and access controls. 2) Monitor system logs and command execution patterns for unusual or unauthorized activity indicative of command injection attempts. 3) Apply principle of least privilege by limiting user permissions on the storage system to the minimum necessary. 4) Prepare for rapid deployment of official patches or firmware updates from Dell once released; engage with Dell support channels to obtain timelines and interim fixes. 5) Employ network segmentation to isolate storage systems from general user networks, reducing the risk of local access by unauthorized users. 6) Conduct regular security audits and vulnerability assessments on storage infrastructure to detect and remediate potential weaknesses. 7) Educate administrators on the risks of local access vulnerabilities and enforce strict operational security policies. These steps go beyond generic advice by focusing on access restriction, monitoring, and preparation for patching specific to Dell Unity environments.

Need more detailed analysis?Upgrade to Pro Console

Technical Details

Data Version
5.2
Assigner Short Name
dell
Date Reserved
2024-10-16T05:04:26.796Z
Cvss Version
3.1
State
PUBLISHED

Threat ID: 69a0a44285912abc71d630f0

Added to database: 2/26/2026, 7:51:30 PM

Last enriched: 2/26/2026, 9:17:35 PM

Last updated: 2/26/2026, 11:16:15 PM

Views: 4

Community Reviews

0 reviews

Crowdsource mitigation strategies, share intel context, and vote on the most helpful responses. Sign in to add your voice and help keep defenders ahead.

Sort by
Loading community insights…

Want to contribute mitigation steps or threat intel context? Sign in or create an account to join the community discussion.

Actions

PRO

Updates to AI analysis require Pro Console access. Upgrade inside Console → Billing.

Please log in to the Console to use AI analysis features.

Need more coverage?

Upgrade to Pro Console in Console -> Billing for AI refresh and higher limits.

For incident response and remediation, OffSeq services can help resolve threats faster.

Latest Threats

Breach by OffSeqOFFSEQFRIENDS — 25% OFF

Check if your credentials are on the dark web

Instant breach scanning across billions of leaked records. Free tier available.

Scan now
OffSeq TrainingCredly Certified

Lead Pen Test Professional

Technical5-day eLearningPECB Accredited
View courses