CVE-2024-49775: CWE-122: Heap-based Buffer Overflow in Siemens Opcenter Execution Foundation

0
Critical
VulnerabilityCVE-2024-49775cvecve-2024-49775cwe-122
Published: Mon Dec 16 2024 (12/16/2024, 15:06:04 UTC)
Source: CVE Database V5
Vendor/Project: Siemens
Product: Opcenter Execution Foundation

Description

CVE-2024-49775 is a critical heap-based buffer overflow vulnerability affecting multiple Siemens industrial software products, including Opcenter Execution Foundation and SIMATIC PCS neo versions prior to specified updates. The flaw exists in the integrated UMC component and allows unauthenticated remote attackers to execute arbitrary code with full system privileges. The vulnerability has a CVSS score of 9. 8, indicating a high impact on confidentiality, integrity, and availability without requiring authentication or user interaction. No known exploits are currently reported in the wild, but the broad range of affected products and critical severity make this a significant threat to industrial control systems. European organizations using Siemens automation and manufacturing software are at risk, especially in countries with strong industrial sectors. Immediate patching and network segmentation are essential to mitigate potential exploitation. Monitoring for unusual network activity targeting the UMC component is also recommended. Siemens users should prioritize updating to the fixed versions as soon as they become available.

AI-Powered Analysis

AILast updated: 01/13/2026, 10:10:51 UTC

Technical Analysis

CVE-2024-49775 is a heap-based buffer overflow vulnerability identified in the integrated UMC component of several Siemens industrial software products, including Opcenter Execution Foundation, Opcenter Intelligence, Opcenter Quality, Opcenter RDnL, SIMATIC PCS neo versions 4.0 through 5.0 (prior to specific updates), SINEC NMS when used with UMC, and multiple versions of the Totally Integrated Automation Portal (TIA Portal) from V16 to V19. The vulnerability allows an unauthenticated remote attacker to trigger a heap overflow condition, which can lead to arbitrary code execution with the privileges of the affected application. The flaw is critical due to its remote exploitability without any authentication or user interaction, and it impacts confidentiality, integrity, and availability of the affected systems. The CVSS v3.1 base score is 9.8, reflecting the ease of exploitation and the severe consequences of a successful attack. Siemens has not yet published patches at the time of this report, but affected users are advised to monitor for updates. The vulnerability poses a significant risk to industrial control systems and manufacturing environments that rely on these Siemens products for automation and operational management. Attackers exploiting this vulnerability could disrupt manufacturing processes, steal sensitive operational data, or cause physical damage by manipulating control systems.

Potential Impact

For European organizations, the impact of CVE-2024-49775 is substantial, particularly in sectors reliant on Siemens industrial automation software such as manufacturing, energy, automotive, and critical infrastructure. Successful exploitation could lead to full system compromise, allowing attackers to disrupt production lines, manipulate quality control data, or cause safety incidents. This could result in operational downtime, financial losses, regulatory penalties, and damage to reputation. The vulnerability's remote and unauthenticated nature increases the risk of widespread exploitation, especially if threat actors develop public exploits. Given Europe's strong industrial base and reliance on Siemens products, the threat could affect supply chains and critical infrastructure resilience. Additionally, the potential for espionage or sabotage by state-sponsored actors targeting strategic industries raises geopolitical concerns. Organizations may face challenges in incident response due to the complexity of industrial environments and the critical nature of affected systems.

Mitigation Recommendations

Organizations should immediately inventory all Siemens products listed as affected and verify their versions against the vulnerable ranges. Until patches are released, implement strict network segmentation to isolate affected systems from untrusted networks, especially the internet. Employ firewall rules and intrusion detection/prevention systems to monitor and block suspicious traffic targeting the UMC component. Disable or restrict remote access to affected Siemens software where possible. Conduct thorough logging and monitoring for anomalous activities indicative of exploitation attempts. Engage with Siemens support channels to obtain early access to patches or workarounds. Develop and test incident response plans specific to industrial control system compromises. Additionally, consider deploying application whitelisting and endpoint protection solutions tailored for industrial environments to reduce attack surface. Regularly update and audit security configurations to ensure compliance with best practices for industrial cybersecurity.

Need more detailed analysis?Upgrade to Pro Console

Technical Details

Data Version
5.2
Assigner Short Name
siemens
Date Reserved
2024-10-18T14:25:05.725Z
Cvss Version
3.1
State
PUBLISHED

Threat ID: 696616cfa60475309f9ce616

Added to database: 1/13/2026, 9:56:31 AM

Last enriched: 1/13/2026, 10:10:51 AM

Last updated: 1/13/2026, 12:09:42 PM

Views: 9

Community Reviews

0 reviews

Crowdsource mitigation strategies, share intel context, and vote on the most helpful responses. Sign in to add your voice and help keep defenders ahead.

Sort by
Loading community insights…

Want to contribute mitigation steps or threat intel context? Sign in or create an account to join the community discussion.

Actions

PRO

Updates to AI analysis require Pro Console access. Upgrade inside Console → Billing.

Please log in to the Console to use AI analysis features.

Need more coverage?

Upgrade to Pro Console in Console -> Billing for AI refresh and higher limits.

For incident response and remediation, OffSeq services can help resolve threats faster.

Latest Threats