CVE-2025-1137: CWE-77 Improper Neutralization of Special Elements used in a Command ('Command Injection') in IBM Storage Scale
IBM Storage Scale 5.2.2.0 and 5.2.2.1, under certain configurations, could allow an authenticated user to execute privileged commands due to improper input neutralization.
AI Analysis
Technical Summary
CVE-2025-1137 is a high-severity command injection vulnerability affecting IBM Storage Scale versions 5.2.2.0 and 5.2.2.1. The vulnerability arises due to improper neutralization of special elements used in operating system commands (CWE-77), which allows an authenticated user to execute arbitrary privileged commands on the affected system. Specifically, under certain configurations, the product fails to adequately sanitize user input before incorporating it into system-level commands, enabling command injection attacks. The vulnerability requires the attacker to have low-level privileges (PR:L) and network access (AV:N), but does not require user interaction (UI:N). The CVSS v3.1 base score is 7.5, indicating a high impact on confidentiality, integrity, and availability. Exploitation could lead to full system compromise, data exfiltration, or disruption of storage services. No known exploits are currently reported in the wild, and no patches have been linked yet. IBM Storage Scale is a software-defined storage solution used in enterprise environments to manage large-scale data storage clusters, often deployed in critical infrastructure and data centers. The vulnerability's exploitation could severely impact the operational stability and security of affected storage environments.
Potential Impact
For European organizations, this vulnerability poses a significant risk due to the critical role IBM Storage Scale plays in managing enterprise storage infrastructure. Successful exploitation could lead to unauthorized command execution with elevated privileges, potentially resulting in data breaches, loss of data integrity, and service outages. This is particularly concerning for sectors with stringent data protection requirements such as finance, healthcare, and government agencies within Europe. The compromise of storage systems could also facilitate lateral movement within networks, increasing the risk of broader organizational impact. Given the high confidentiality, integrity, and availability impacts, organizations could face regulatory penalties under GDPR if sensitive personal data is exposed or compromised. Additionally, operational disruptions could affect business continuity and damage organizational reputation.
Mitigation Recommendations
European organizations using IBM Storage Scale 5.2.2.0 or 5.2.2.1 should prioritize the following mitigations: 1) Immediately review and restrict access controls to ensure only fully trusted and necessary users have authenticated access to the storage management interfaces. 2) Implement strict input validation and sanitization at the application layer where possible, to reduce the risk of command injection. 3) Monitor system logs and command execution traces for unusual or unauthorized commands indicative of exploitation attempts. 4) Apply network segmentation to isolate storage management interfaces from general user networks, limiting exposure. 5) Engage with IBM support to obtain and deploy patches or updates as soon as they become available. 6) Conduct thorough security audits and penetration testing focused on command injection vectors within the storage environment. 7) Employ runtime application self-protection (RASP) or host-based intrusion detection systems (HIDS) to detect and block suspicious command execution patterns. These steps go beyond generic advice by focusing on access control tightening, monitoring, and proactive detection tailored to the nature of the vulnerability and the product environment.
Affected Countries
Germany, France, United Kingdom, Netherlands, Italy, Spain, Sweden
CVE-2025-1137: CWE-77 Improper Neutralization of Special Elements used in a Command ('Command Injection') in IBM Storage Scale
Description
IBM Storage Scale 5.2.2.0 and 5.2.2.1, under certain configurations, could allow an authenticated user to execute privileged commands due to improper input neutralization.
AI-Powered Analysis
Technical Analysis
CVE-2025-1137 is a high-severity command injection vulnerability affecting IBM Storage Scale versions 5.2.2.0 and 5.2.2.1. The vulnerability arises due to improper neutralization of special elements used in operating system commands (CWE-77), which allows an authenticated user to execute arbitrary privileged commands on the affected system. Specifically, under certain configurations, the product fails to adequately sanitize user input before incorporating it into system-level commands, enabling command injection attacks. The vulnerability requires the attacker to have low-level privileges (PR:L) and network access (AV:N), but does not require user interaction (UI:N). The CVSS v3.1 base score is 7.5, indicating a high impact on confidentiality, integrity, and availability. Exploitation could lead to full system compromise, data exfiltration, or disruption of storage services. No known exploits are currently reported in the wild, and no patches have been linked yet. IBM Storage Scale is a software-defined storage solution used in enterprise environments to manage large-scale data storage clusters, often deployed in critical infrastructure and data centers. The vulnerability's exploitation could severely impact the operational stability and security of affected storage environments.
Potential Impact
For European organizations, this vulnerability poses a significant risk due to the critical role IBM Storage Scale plays in managing enterprise storage infrastructure. Successful exploitation could lead to unauthorized command execution with elevated privileges, potentially resulting in data breaches, loss of data integrity, and service outages. This is particularly concerning for sectors with stringent data protection requirements such as finance, healthcare, and government agencies within Europe. The compromise of storage systems could also facilitate lateral movement within networks, increasing the risk of broader organizational impact. Given the high confidentiality, integrity, and availability impacts, organizations could face regulatory penalties under GDPR if sensitive personal data is exposed or compromised. Additionally, operational disruptions could affect business continuity and damage organizational reputation.
Mitigation Recommendations
European organizations using IBM Storage Scale 5.2.2.0 or 5.2.2.1 should prioritize the following mitigations: 1) Immediately review and restrict access controls to ensure only fully trusted and necessary users have authenticated access to the storage management interfaces. 2) Implement strict input validation and sanitization at the application layer where possible, to reduce the risk of command injection. 3) Monitor system logs and command execution traces for unusual or unauthorized commands indicative of exploitation attempts. 4) Apply network segmentation to isolate storage management interfaces from general user networks, limiting exposure. 5) Engage with IBM support to obtain and deploy patches or updates as soon as they become available. 6) Conduct thorough security audits and penetration testing focused on command injection vectors within the storage environment. 7) Employ runtime application self-protection (RASP) or host-based intrusion detection systems (HIDS) to detect and block suspicious command execution patterns. These steps go beyond generic advice by focusing on access control tightening, monitoring, and proactive detection tailored to the nature of the vulnerability and the product environment.
Affected Countries
For access to advanced analysis and higher rate limits, contact root@offseq.com
Technical Details
- Data Version
- 5.1
- Assigner Short Name
- ibm
- Date Reserved
- 2025-02-08T20:16:19.164Z
- Cisa Enriched
- true
- Cvss Version
- 3.1
- State
- PUBLISHED
Threat ID: 682d9816c4522896dcbd66fc
Added to database: 5/21/2025, 9:08:38 AM
Last enriched: 7/12/2025, 2:19:00 AM
Last updated: 8/11/2025, 9:31:51 AM
Views: 15
Related Threats
CVE-2025-9007: Buffer Overflow in Tenda CH22
HighCVE-2025-9006: Buffer Overflow in Tenda CH22
HighCVE-2025-9005: Information Exposure Through Error Message in mtons mblog
MediumCVE-2025-9004: Improper Restriction of Excessive Authentication Attempts in mtons mblog
MediumCVE-2025-9003: Cross Site Scripting in D-Link DIR-818LW
MediumActions
Updates to AI analysis are available only with a Pro account. Contact root@offseq.com for access.
External Links
Need enhanced features?
Contact root@offseq.com for Pro access with improved analysis and higher rate limits.