Skip to main content
Press slash or control plus K to focus the search. Use the arrow keys to navigate results and press enter to open a threat.
Reconnecting to live updates…

CVE-2025-12995: CWE-307 Improper Restriction of Excessive Authentication Attempts in Medtronic CareLink Network

0
High
VulnerabilityCVE-2025-12995cvecve-2025-12995cwe-307
Published: Thu Dec 04 2025 (12/04/2025, 20:03:00 UTC)
Source: CVE Database V5
Vendor/Project: Medtronic
Product: CareLink Network

Description

Medtronic CareLink Network allows an unauthenticated remote attacker to perform a brute force attack on an API endpoint that could be used to determine a valid password under certain circumstances. This issue affects CareLink Network: before December 4, 2025.

AI-Powered Analysis

AILast updated: 12/04/2025, 20:25:22 UTC

Technical Analysis

CVE-2025-12995 is a vulnerability classified under CWE-307, indicating improper restriction of excessive authentication attempts in the Medtronic CareLink Network. The flaw allows unauthenticated remote attackers to perform brute force attacks against an API endpoint, which can be leveraged to enumerate or discover valid passwords under certain conditions. The vulnerability affects all versions of the CareLink Network prior to December 4, 2025. The CVSS 3.1 base score is 8.1, reflecting a high severity due to the network attack vector (AV:N), no privileges required (PR:N), no user interaction (UI:N), and high impact on confidentiality, integrity, and availability (C:H/I:H/A:H). The attack complexity is high (AC:H), indicating some conditions must be met or the attack requires significant effort or resources. The vulnerability could allow attackers to gain unauthorized access to sensitive patient data and control over medical device management systems, posing significant risks to patient safety and data privacy. Although no known exploits are currently reported in the wild, the lack of patches and the critical nature of the system make this a pressing concern. The CareLink Network is widely used in healthcare environments for remote monitoring and management of implantable medical devices, making the impact of exploitation potentially severe. The vulnerability highlights the need for robust authentication controls and monitoring in medical device networks.

Potential Impact

For European organizations, particularly healthcare providers and medical device management facilities, this vulnerability poses a significant risk. Exploitation could lead to unauthorized access to patient data, manipulation of device settings, and disruption of critical healthcare services. This could result in breaches of GDPR due to exposure of sensitive health information, legal liabilities, and loss of patient trust. The availability of the CareLink Network could be compromised, affecting remote monitoring and timely medical interventions. Given the critical nature of medical devices managed via this network, exploitation could have direct patient safety implications, including incorrect device configurations or denial of service. The high confidentiality, integrity, and availability impacts underscore the potential for severe operational and reputational damage. European healthcare infrastructure, already a target for cyberattacks, may face increased threats from attackers exploiting this vulnerability, especially if no mitigations are applied promptly.

Mitigation Recommendations

Organizations should immediately implement strict rate limiting and account lockout mechanisms on the affected API endpoints to prevent brute force attempts. Deploying Web Application Firewalls (WAFs) with custom rules to detect and block repeated authentication failures is recommended. Continuous monitoring and alerting on authentication anomalies should be established to detect potential attack attempts early. Network segmentation should be enforced to isolate the CareLink Network from broader enterprise networks, limiting attacker lateral movement. Multi-factor authentication (MFA) should be applied where possible to add an additional layer of security. Medtronic and healthcare providers should prioritize patch development and deployment once available. In the interim, conducting thorough security assessments and penetration testing focused on authentication controls can help identify weaknesses. Training staff on recognizing signs of brute force attacks and ensuring incident response plans include scenarios involving medical device network compromises will enhance preparedness.

Need more detailed analysis?Get Pro

Technical Details

Data Version
5.2
Assigner Short Name
Medtronic
Date Reserved
2025-11-11T03:38:45.676Z
Cvss Version
3.1
State
PUBLISHED

Threat ID: 6931eb9b6255310dc4c890a7

Added to database: 12/4/2025, 8:14:19 PM

Last enriched: 12/4/2025, 8:25:22 PM

Last updated: 12/5/2025, 2:38:32 AM

Views: 9

Community Reviews

0 reviews

Crowdsource mitigation strategies, share intel context, and vote on the most helpful responses. Sign in to add your voice and help keep defenders ahead.

Sort by
Loading community insights…

Want to contribute mitigation steps or threat intel context? Sign in or create an account to join the community discussion.

Actions

PRO

Updates to AI analysis require Pro Console access. Upgrade inside Console → Billing.

Please log in to the Console to use AI analysis features.

Need enhanced features?

Contact root@offseq.com for Pro access with improved analysis and higher rate limits.

Latest Threats