Skip to main content
VulnerabilityPublished

CVE-2025-15203: SohuTV CacheCloud · Cross-site Scripting

Affects SohuTV CacheCloudSource CVE Database V5

0

Public exploit available · CVSS 4.8 Medium.

Data as of 26 Oct 2026, 10:12 UTC

CVSS 4.0 base score
4.8Medium
How severe the flaw is on the 0–10 CVSS scale.
EPSS
0.2% chance of exploitation in 30 days – higher than 15% of CVEsExploit Prediction Scoring System: the likelihood attackers will use this flaw soon.
CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:P/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N/E:P

Exploitation evidence

  1. Disclosed: evidence found.

    CVE published 29 Dec 2025

  2. Detectable: no evidence on record.

    No public nuclei template indexed

  3. Weaponised: evidence found.

    CVSS exploit maturity: proof of concept public

  4. Exploited in the wild: no evidence on record.

    Not in CISA KEV and no source reports exploitation

  5. Observed by OffSeq Mirage: no evidence on record.

    No attack traffic recorded by OffSeq Mirage sensors

A missing step is not evidence of safety. Sources: cve.org (opens in a new tab), CVSS vector, the Metasploit, Exploit-DB and nuclei-templates index as of 26 Oct 2026.

What to do

Affected software

ProductAffectedFixed in
GitHubsohutv/cachecloudpkg:github/sohutv/cachecloudOther threatsAffected
  • =3.0
  • =3.1
  • =3.2.0
Fixed in–

Check your own hosts for these packages with threat-finder (opens in a new tab), our free open-source scanner.

AI-suggested

European organizations should implement strict input validation and output encoding on all user-supplied data processed by CacheCloud interfaces, especially the affected ResourceController index function. Employ web application firewalls (WAFs) with updated signatures to detect and block XSS attack patterns targeting CacheCloud. Monitor web server logs and application behavior for unusual requests or error patterns indicative of exploitation attempts. Educate users about the risks of clicking suspicious links or interacting with untrusted content to reduce successful user interaction exploitation. If possible, isolate CacheCloud instances behind secure network segments and restrict access to trusted users. Engage with the vendor or community to track patch releases and apply updates promptly once available. Consider deploying Content Security Policy (CSP) headers to limit the impact of injected scripts. Finally, conduct regular security assessments and penetration testing focused on web application vulnerabilities including XSS.

Description

A vulnerability was found in SohuTV CacheCloud up to 3.2.0. This impacts the function index of the file src/main/java/com/sohu/cache/web/controller/ResourceController.java. Performing manipulation results in cross site scripting. It is possible to initiate the attack remotely. The exploit has been made public and could be used. The project was informed of the problem early through an issue report but has not responded yet.

References