CVE-2025-15216: Tenda AC23 · Stack-based Buffer Overflow
Affects Tenda AC23Source CVE Database V5
Not known to be exploited · CVSS 8.7 High.
Data as of 25 Oct 2026, 19:02 UTC
- EPSS
- 0.7% chance of exploitation in 30 days – higher than 54% of CVEsExploit Prediction Scoring System: the likelihood attackers will use this flaw soon.
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:PExploitation evidence
Disclosed: evidence found.
CVE published 30 Dec 2025
Detectable: no evidence on record.
No public nuclei template indexed
Weaponised: no evidence on record.
No public exploit code indexed in Metasploit or Exploit-DB
Exploited in the wildExploited: no evidence on record.
Not in CISA KEV and no source reports exploitation
Observed by OffSeq MirageSeen by Mirage: no evidence on record.
No attack traffic recorded by OffSeq Mirage sensors
A missing step is not evidence of safety. Sources: cve.org (opens in a new tab), the Metasploit, Exploit-DB and nuclei-templates index as of 2026-10-25.
What to do
Affected software
| Product | Affected | Fixed in |
|---|---|---|
| Tenda AC23 | Affected
| Fixed in– |
AI-suggested
To mitigate CVE-2025-15216, organizations should first verify if they are using Tenda AC23 routers with firmware version 16.03.07.52. Immediate steps include disabling remote management interfaces to reduce exposure to external attackers. Network segmentation should be employed to isolate vulnerable devices from critical assets. Monitoring network traffic for unusual activity targeting the /goform/SetIpMacBind endpoint can help detect exploitation attempts. If official patches become available, they should be applied promptly. In the absence of patches, deploying Web Application Firewalls (WAFs) or Intrusion Prevention Systems (IPS) with custom rules to block malformed requests containing suspicious bindnum parameters can provide interim protection. Regular firmware updates and vendor advisories should be monitored closely. Additionally, organizations should conduct internal audits to identify and replace vulnerable devices where feasible, and educate users on the risks of enabling remote management features without adequate security controls.
Description
A vulnerability was identified in Tenda AC23 16.03.07.52. This impacts the function fromSetIpMacBind of the file /goform/SetIpMacBind. Such manipulation of the argument bindnum leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit is publicly available and might be used.