Skip to main content
CVE-2025-1907VulnerabilityPublished

CVE-2025-1907: Instantel Micromate · Missing Authentication

Affects Instantel MicromateSource CVE Database V5

0

Not known to be exploited · CVSS 9.8 Critical.

Data as of 26 Oct 2026, 08:30 UTC

CVSS 3.1 base score
9.8Critical
How severe the flaw is on the 0–10 CVSS scale.
EPSS
0.8% chance of exploitation in 30 days – higher than 57% of CVEsExploit Prediction Scoring System: the likelihood attackers will use this flaw soon.
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Exploitation evidence

  1. Disclosed: evidence found.

    CVE published 29 May 2025

  2. Detectable: no evidence on record.

    No public nuclei template indexed

  3. Weaponised: no evidence on record.

    No public exploit code indexed in Metasploit or Exploit-DB

  4. Exploited in the wild: no evidence on record.

    Not in CISA KEV and no source reports exploitation

  5. Observed by OffSeq Mirage: no evidence on record.

    No attack traffic recorded by OffSeq Mirage sensors

A missing step is not evidence of safety. Sources: cve.org (opens in a new tab), the Metasploit, Exploit-DB and nuclei-templates index as of 26 Oct 2026.

What to do

Affected software

ProductAffectedFixed in
Instantel MicromateAffected
  • *
Fixed in–

AI-suggested

Since no official patches are currently available, European organizations should implement immediate compensating controls. First, restrict physical and network access to the Instantel Micromate configuration port by placing devices in secure, access-controlled locations and segmenting their network environment using VLANs or firewalls to limit connectivity only to trusted management systems. Employ network monitoring to detect unusual traffic patterns or unauthorized access attempts targeting the device. Where possible, disable or block unused configuration interfaces. Implement strict access control policies and ensure that only authorized personnel can connect to these devices. Additionally, consider deploying intrusion detection systems (IDS) tailored to industrial control systems to identify potential exploitation attempts. Organizations should engage with Instantel for updates on patches or firmware upgrades and plan for timely deployment once available. Finally, conduct regular security audits and vulnerability assessments on all industrial monitoring devices to identify and remediate similar weaknesses proactively.

Description

Instantel Micromate lacks authentication on a configuration port which could allow an attacker to execute commands if connected.