CVE-2025-1985: CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') in Pepperl+Fuchs Profinet Gateway FB8122A.1.EL
Due to improper neutralization of input during web page generation (XSS) an unauthenticated remote attacker can inject HTML code into the Web-UI in the affected device.
AI Analysis
Technical Summary
CVE-2025-1985 is a medium-severity vulnerability classified under CWE-79, which refers to improper neutralization of input during web page generation, commonly known as Cross-site Scripting (XSS). This vulnerability affects the Pepperl+Fuchs Profinet Gateway FB8122A.1.EL device. The core issue arises because the device's web user interface (Web-UI) does not properly sanitize or neutralize user-supplied input before rendering it in the web pages. As a result, an unauthenticated remote attacker can inject malicious HTML or JavaScript code into the Web-UI. This injection can lead to the execution of arbitrary scripts in the context of the victim's browser session when they access the device's web interface. The CVSS v3.1 score of 6.1 reflects a medium severity, with the vector indicating network attack vector (AV:N), low attack complexity (AC:L), no privileges required (PR:N), but requiring user interaction (UI:R). The scope is changed (S:C), meaning the vulnerability affects resources beyond the vulnerable component. The impact is limited to low confidentiality and integrity impacts, with no availability impact. No known exploits are currently reported in the wild, and no patches have been linked yet. The vulnerability was reserved in early March 2025 and published in late May 2025. The affected product, Profinet Gateway FB8122A.1.EL, is used in industrial automation environments to facilitate communication over Profinet networks, which are common in manufacturing and process control industries. The presence of an XSS vulnerability in such a device could allow attackers to conduct phishing attacks, steal session cookies, or perform actions on behalf of legitimate users accessing the Web-UI, potentially leading to further compromise of the industrial control environment.
Potential Impact
For European organizations, especially those in manufacturing, industrial automation, and critical infrastructure sectors, this vulnerability poses a tangible risk. The Profinet Gateway is a critical component in industrial networks, and compromise of its Web-UI could allow attackers to manipulate device configurations or gain footholds within operational technology (OT) networks. Although the vulnerability requires user interaction, the fact that no authentication is needed lowers the barrier for exploitation. Attackers could craft malicious links or web pages that, when accessed by engineers or administrators managing the gateway, execute injected scripts. This could lead to credential theft, session hijacking, or unauthorized configuration changes, potentially disrupting industrial processes or enabling lateral movement within the network. Given the increasing convergence of IT and OT environments in Europe, exploitation could have cascading effects on production lines, safety systems, and supply chains. The medium severity rating suggests that while the vulnerability is not immediately catastrophic, it should be addressed promptly to prevent escalation. The lack of known exploits in the wild currently provides a window for mitigation before active attacks emerge.
Mitigation Recommendations
1. Immediate mitigation should include restricting access to the Profinet Gateway's Web-UI to trusted networks only, using network segmentation and firewall rules to limit exposure to the internet or untrusted zones. 2. Implement strict access control policies requiring multi-factor authentication for any administrative access to the device, even if the vulnerability itself does not require authentication. 3. Employ web application firewalls (WAFs) or intrusion prevention systems (IPS) capable of detecting and blocking XSS payloads targeting the device's Web-UI. 4. Monitor network traffic and device logs for unusual activity or repeated access attempts that could indicate exploitation attempts. 5. Engage with Pepperl+Fuchs for official patches or firmware updates addressing this vulnerability and apply them as soon as they become available. 6. Educate personnel who access the device's Web-UI about the risks of clicking on unsolicited links or opening suspicious web content, emphasizing the need for caution to prevent user interaction-based exploitation. 7. Consider deploying browser security policies such as Content Security Policy (CSP) headers if configurable on the device to reduce the impact of injected scripts. 8. Regularly audit and update the device firmware and configurations to ensure no additional vulnerabilities are present.
Affected Countries
Germany, France, Italy, Spain, Netherlands, Belgium, Poland, Czech Republic
CVE-2025-1985: CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') in Pepperl+Fuchs Profinet Gateway FB8122A.1.EL
Description
Due to improper neutralization of input during web page generation (XSS) an unauthenticated remote attacker can inject HTML code into the Web-UI in the affected device.
AI-Powered Analysis
Technical Analysis
CVE-2025-1985 is a medium-severity vulnerability classified under CWE-79, which refers to improper neutralization of input during web page generation, commonly known as Cross-site Scripting (XSS). This vulnerability affects the Pepperl+Fuchs Profinet Gateway FB8122A.1.EL device. The core issue arises because the device's web user interface (Web-UI) does not properly sanitize or neutralize user-supplied input before rendering it in the web pages. As a result, an unauthenticated remote attacker can inject malicious HTML or JavaScript code into the Web-UI. This injection can lead to the execution of arbitrary scripts in the context of the victim's browser session when they access the device's web interface. The CVSS v3.1 score of 6.1 reflects a medium severity, with the vector indicating network attack vector (AV:N), low attack complexity (AC:L), no privileges required (PR:N), but requiring user interaction (UI:R). The scope is changed (S:C), meaning the vulnerability affects resources beyond the vulnerable component. The impact is limited to low confidentiality and integrity impacts, with no availability impact. No known exploits are currently reported in the wild, and no patches have been linked yet. The vulnerability was reserved in early March 2025 and published in late May 2025. The affected product, Profinet Gateway FB8122A.1.EL, is used in industrial automation environments to facilitate communication over Profinet networks, which are common in manufacturing and process control industries. The presence of an XSS vulnerability in such a device could allow attackers to conduct phishing attacks, steal session cookies, or perform actions on behalf of legitimate users accessing the Web-UI, potentially leading to further compromise of the industrial control environment.
Potential Impact
For European organizations, especially those in manufacturing, industrial automation, and critical infrastructure sectors, this vulnerability poses a tangible risk. The Profinet Gateway is a critical component in industrial networks, and compromise of its Web-UI could allow attackers to manipulate device configurations or gain footholds within operational technology (OT) networks. Although the vulnerability requires user interaction, the fact that no authentication is needed lowers the barrier for exploitation. Attackers could craft malicious links or web pages that, when accessed by engineers or administrators managing the gateway, execute injected scripts. This could lead to credential theft, session hijacking, or unauthorized configuration changes, potentially disrupting industrial processes or enabling lateral movement within the network. Given the increasing convergence of IT and OT environments in Europe, exploitation could have cascading effects on production lines, safety systems, and supply chains. The medium severity rating suggests that while the vulnerability is not immediately catastrophic, it should be addressed promptly to prevent escalation. The lack of known exploits in the wild currently provides a window for mitigation before active attacks emerge.
Mitigation Recommendations
1. Immediate mitigation should include restricting access to the Profinet Gateway's Web-UI to trusted networks only, using network segmentation and firewall rules to limit exposure to the internet or untrusted zones. 2. Implement strict access control policies requiring multi-factor authentication for any administrative access to the device, even if the vulnerability itself does not require authentication. 3. Employ web application firewalls (WAFs) or intrusion prevention systems (IPS) capable of detecting and blocking XSS payloads targeting the device's Web-UI. 4. Monitor network traffic and device logs for unusual activity or repeated access attempts that could indicate exploitation attempts. 5. Engage with Pepperl+Fuchs for official patches or firmware updates addressing this vulnerability and apply them as soon as they become available. 6. Educate personnel who access the device's Web-UI about the risks of clicking on unsolicited links or opening suspicious web content, emphasizing the need for caution to prevent user interaction-based exploitation. 7. Consider deploying browser security policies such as Content Security Policy (CSP) headers if configurable on the device to reduce the impact of injected scripts. 8. Regularly audit and update the device firmware and configurations to ensure no additional vulnerabilities are present.
Affected Countries
For access to advanced analysis and higher rate limits, contact root@offseq.com
Technical Details
- Data Version
- 5.1
- Assigner Short Name
- CERTVDE
- Date Reserved
- 2025-03-05T14:01:01.177Z
- Cisa Enriched
- false
- Cvss Version
- 3.1
- State
- PUBLISHED
Threat ID: 683428360acd01a249284729
Added to database: 5/26/2025, 8:37:10 AM
Last enriched: 7/9/2025, 2:10:51 PM
Last updated: 7/30/2025, 4:09:47 PM
Views: 11
Related Threats
CVE-2025-8818: OS Command Injection in Linksys RE6250
MediumCVE-2025-8816: Stack-based Buffer Overflow in Linksys RE6250
HighCVE-2025-8815: Path Traversal in 猫宁i Morning
MediumCVE-2025-8814: Cross-Site Request Forgery in atjiu pybbs
MediumCVE-2025-8813: Open Redirect in atjiu pybbs
MediumActions
Updates to AI analysis are available only with a Pro account. Contact root@offseq.com for access.
External Links
Need enhanced features?
Contact root@offseq.com for Pro access with improved analysis and higher rate limits.