Description

Time-of-check Time-of-use race condition for some Intel(R) Connectivity Performance Suite software installers before version 40.24.11210 may allow an authenticated user to potentially enable escalation of privilege via local access.

AI-Powered Analysis

AILast updated: 08/20/2025, 01:31:45 UTC

Technical Analysis

CVE-2025-20074 is a high-severity vulnerability identified in Intel(R) Connectivity Performance Suite software installers prior to version 40.24.11210. The flaw arises from a time-of-check to time-of-use (TOCTOU) race condition during the installation process. Specifically, this race condition occurs when the installer performs security checks on certain resources or files and then, before using those resources, an attacker can alter them. This vulnerability requires local authenticated access, meaning an attacker must have some level of legitimate user privileges on the affected system. Exploiting this flaw could allow such a user to escalate their privileges, potentially gaining higher-level system or administrative rights. The CVSS 4.0 base score of 7.3 reflects the significant impact on confidentiality, integrity, and availability, with low attack complexity but requiring privileges and no user interaction. Although no known exploits are currently reported in the wild, the vulnerability's nature makes it a serious concern, especially in environments where Intel Connectivity Performance Suite is widely deployed. The vulnerability does not require network access, limiting remote exploitation but increasing risk in multi-user or shared environments. Intel has reserved the CVE and published the details, but no patch links are yet provided, emphasizing the need for vigilance and proactive mitigation.

Potential Impact

For European organizations, the impact of CVE-2025-20074 can be substantial, particularly in sectors relying heavily on Intel hardware and associated software suites, such as telecommunications, manufacturing, and enterprise IT environments. The privilege escalation could allow an attacker with limited access to gain administrative control, leading to unauthorized access to sensitive data, disruption of services, or further lateral movement within corporate networks. This is especially critical for organizations bound by strict data protection regulations like GDPR, where unauthorized data access or breaches can result in severe legal and financial penalties. Additionally, the vulnerability could undermine the security posture of critical infrastructure and industrial control systems that utilize Intel Connectivity Performance Suite, potentially affecting operational continuity. Given the local access requirement, insider threats or compromised user accounts pose a significant risk vector. The absence of known exploits currently provides a window for organizations to implement mitigations before active exploitation occurs.

Mitigation Recommendations

European organizations should prioritize upgrading Intel Connectivity Performance Suite installers to version 40.24.11210 or later as soon as the patch becomes available. Until then, strict access controls should be enforced to limit local authenticated user privileges, minimizing the number of users who can install or modify software. Implementing application whitelisting and monitoring installer execution can help detect and prevent unauthorized installation attempts. Employing endpoint detection and response (EDR) solutions to monitor for suspicious privilege escalation behaviors is advisable. Additionally, organizations should conduct regular audits of user privileges and system logs to identify potential misuse. Network segmentation and the principle of least privilege should be rigorously applied to reduce the risk of lateral movement if an escalation occurs. Finally, maintaining up-to-date backups and incident response plans will aid in rapid recovery if exploitation is detected.

Need more detailed analysis?Get Pro

Technical Details

Data Version
5.1
Assigner Short Name
intel
Date Reserved
2024-10-12T03:00:15.435Z
Cvss Version
4.0
State
PUBLISHED

Threat ID: 689b774fad5a09ad003492ac

Added to database: 8/12/2025, 5:18:07 PM

Last enriched: 8/20/2025, 1:31:45 AM

Last updated: 9/5/2025, 12:09:21 AM

Views: 5

Actions

PRO

Updates to AI analysis are available only with a Pro account. Contact root@offseq.com for access.

Please log in to the Console to use AI analysis features.

Need enhanced features?

Contact root@offseq.com for Pro access with improved analysis and higher rate limits.

Latest Threats