Skip to main content
Press slash or control plus K to focus the search. Use the arrow keys to navigate results and press enter to open a threat.
Reconnecting to live updates…

CVE-2025-22472: CWE-77: Improper Neutralization of Special Elements used in a Command ('Command Injection') in Dell SmartFabric OS10 Software

0
High
VulnerabilityCVE-2025-22472cvecve-2025-22472cwe-77
Published: Mon Mar 17 2025 (03/17/2025, 17:47:44 UTC)
Source: CVE Database V5
Vendor/Project: Dell
Product: SmartFabric OS10 Software

Description

Dell SmartFabric OS10 Software, version(s) 10.5.4.x, 10.5.5.x, 10.5.6.x, 10.6.0.x, contain(s) an Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to execution of commands with elevated privileges.

AI-Powered Analysis

AILast updated: 02/26/2026, 20:31:22 UTC

Technical Analysis

CVE-2025-22472 identifies a command injection vulnerability in Dell SmartFabric OS10 Software, specifically affecting versions 10.5.4.x, 10.5.5.x, 10.5.6.x, and 10.6.0.x. The root cause is improper neutralization of special elements used in command construction (CWE-77), which allows an attacker with low privileges and local access to inject malicious commands. This injection flaw can lead to execution of arbitrary commands with elevated privileges, bypassing normal access controls. The vulnerability does not require user interaction but does require the attacker to have local access to the device, such as through a compromised account or physical access. The CVSS v3.1 score of 7.8 reflects high impact on confidentiality, integrity, and availability, with low attack complexity and low privileges required. Dell SmartFabric OS10 is a network operating system used in data center and enterprise network switches, making this vulnerability critical for network infrastructure security. Although no public exploits are known yet, the potential for privilege escalation and full system compromise is significant. No official patches have been linked at the time of publication, so mitigation strategies must be implemented promptly.

Potential Impact

The impact of this vulnerability is substantial for organizations relying on Dell SmartFabric OS10 for their network infrastructure. Exploitation can lead to unauthorized command execution with elevated privileges, allowing attackers to manipulate network configurations, intercept or redirect traffic, disrupt network availability, or establish persistent footholds. This can compromise the confidentiality and integrity of sensitive data traversing the network and disrupt critical business operations. Given the role of SmartFabric OS10 in data centers and enterprise networks, successful exploitation could affect large-scale network environments, potentially impacting multiple connected systems and services. The requirement for local access limits remote exploitation but does not eliminate risk, as attackers may gain local access through other means such as credential theft or insider threats. The absence of known exploits currently provides a window for proactive defense, but the high severity score underscores the urgency of addressing this vulnerability.

Mitigation Recommendations

1. Monitor Dell’s official security advisories closely for patches addressing CVE-2025-22472 and apply them immediately upon release. 2. Restrict local access to devices running SmartFabric OS10 to trusted personnel only, enforcing strict access controls and multi-factor authentication where possible. 3. Audit and limit user privileges on affected devices to the minimum necessary, reducing the risk of low-privileged accounts being leveraged for exploitation. 4. Implement network segmentation to isolate management interfaces of network devices, preventing unauthorized lateral movement. 5. Employ intrusion detection and prevention systems (IDS/IPS) to monitor for anomalous command execution or privilege escalation attempts on network devices. 6. Regularly review and harden device configurations to eliminate unnecessary services or interfaces that could provide local access. 7. Conduct security awareness training for administrators to recognize and report suspicious activity related to device access. 8. Maintain comprehensive logging and monitoring of device access and command execution to facilitate rapid detection and response to potential exploitation attempts.

Need more detailed analysis?Upgrade to Pro Console

Technical Details

Data Version
5.2
Assigner Short Name
dell
Date Reserved
2025-01-07T06:04:12.134Z
Cvss Version
3.1
State
PUBLISHED

Threat ID: 69a0a45385912abc71d656ad

Added to database: 2/26/2026, 7:51:47 PM

Last enriched: 2/26/2026, 8:31:22 PM

Last updated: 2/26/2026, 11:15:25 PM

Views: 3

Community Reviews

0 reviews

Crowdsource mitigation strategies, share intel context, and vote on the most helpful responses. Sign in to add your voice and help keep defenders ahead.

Sort by
Loading community insights…

Want to contribute mitigation steps or threat intel context? Sign in or create an account to join the community discussion.

Actions

PRO

Updates to AI analysis require Pro Console access. Upgrade inside Console → Billing.

Please log in to the Console to use AI analysis features.

Need more coverage?

Upgrade to Pro Console in Console -> Billing for AI refresh and higher limits.

For incident response and remediation, OffSeq services can help resolve threats faster.

Latest Threats

Breach by OffSeqOFFSEQFRIENDS — 25% OFF

Check if your credentials are on the dark web

Instant breach scanning across billions of leaked records. Free tier available.

Scan now
OffSeq TrainingCredly Certified

Lead Pen Test Professional

Technical5-day eLearningPECB Accredited
View courses