CVE-2025-23365: Siemens TIA Administrator · Improper Access Control
Affects Siemens TIA AdministratorSource CVE Database V5
Not known to be exploited · CVSS 7.8 High : upgrade to 3.0.6 soon.
Data as of 26 Oct 2026, 08:30 UTC
- EPSS
- 0.1% chance of exploitation in 30 days – higher than 3% of CVEsExploit Prediction Scoring System: the likelihood attackers will use this flaw soon.
- Patch
- Available – fixed in 3.0.6
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:CExploitation evidence
Disclosed: evidence found.
CVE published 8 Jul 2025
Detectable: no evidence on record.
No public nuclei template indexed
Weaponised: no evidence on record.
No public exploit code indexed in Metasploit or Exploit-DB
Exploited in the wildExploited: no evidence on record.
Not in CISA KEV and no source reports exploitation
Observed by OffSeq MirageSeen by Mirage: no evidence on record.
No attack traffic recorded by OffSeq Mirage sensors
A missing step is not evidence of safety. Sources: cve.org (opens in a new tab), the Metasploit, Exploit-DB and nuclei-templates index as of 26 Oct 2026.
What to do
Upgrade Siemens TIA Administrator to 3.0.6.
Affected software
| Product | Affected | Fixed in |
|---|---|---|
| Siemens TIA Administrator | Affected
| Fixed in
|
AI-suggested
Organizations should prioritize upgrading Siemens TIA Administrator to version 3.0.6 or later, where this vulnerability is addressed. Until patching is possible, implement strict access controls to limit user permissions, ensuring that only trusted personnel have access to systems running TIA Administrator. Employ application whitelisting and integrity monitoring to detect unauthorized modifications to cache files and download paths. Regularly audit user activities and system logs for suspicious behavior indicative of privilege escalation attempts. Network segmentation should be enforced to isolate engineering workstations from general IT networks and external access. Additionally, implement endpoint detection and response (EDR) solutions capable of identifying anomalous process executions and file modifications. Conduct security awareness training for staff to recognize and report unusual system behavior. Finally, maintain an incident response plan tailored to industrial control system environments to quickly contain and remediate potential exploitation.
Description
A vulnerability has been identified in TIA Administrator (All versions < V3.0.6). The affected application allows low-privileged users to trigger installations by overwriting cache files and modifying the downloads path. This would allow an attacker to escalate privilege and exceute arbitrary code.