Skip to main content
Press slash or control plus K to focus the search. Use the arrow keys to navigate results and press enter to open a threat.
Reconnecting to live updates…

CVE-2025-23841: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') in foo123 Top Flash Embed

0
Unknown
VulnerabilityCVE-2025-23841cvecve-2025-23841
Published: Thu Jan 16 2025 (01/16/2025, 20:07:20 UTC)
Source: CVE Database V5
Vendor/Project: foo123
Product: Top Flash Embed

Description

Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in foo123 Top Flash Embed top-flash-embed allows Stored XSS.This issue affects Top Flash Embed: from n/a through <= 0.3.4.

AI-Powered Analysis

Machine-generated threat intelligence

AILast updated: 04/01/2026, 20:19:45 UTC

Technical Analysis

CVE-2025-23841 is a stored cross-site scripting vulnerability found in the foo123 Top Flash Embed plugin, specifically affecting versions up to 0.3.4. The vulnerability is caused by improper neutralization of user-supplied input during the generation of web pages, which allows attackers to inject malicious JavaScript code that is stored on the server and served to other users. This persistent XSS flaw can be exploited by attackers to execute arbitrary scripts in the context of the victim’s browser, potentially leading to session hijacking, credential theft, defacement, or malware distribution. The vulnerability does not require authentication or user interaction beyond visiting a compromised page, making it easier to exploit. The affected product, Top Flash Embed, is a tool used to embed Flash content on websites, which, although less common today, is still in use in certain legacy or niche environments. No CVSS score has been assigned yet, and no official patches or fixes have been released as of the publication date. The vulnerability was publicly disclosed on January 16, 2025, by Patchstack. Due to the lack of patches and the persistent nature of stored XSS, affected sites remain at risk until mitigations are applied or the plugin is updated.

Potential Impact

The impact of CVE-2025-23841 is significant for organizations using the vulnerable Top Flash Embed plugin. Successful exploitation allows attackers to execute arbitrary JavaScript in the context of users’ browsers, which can lead to theft of sensitive information such as session cookies, login credentials, or personal data. This can facilitate account takeover, unauthorized access, and further compromise of the affected web application. Additionally, attackers can deface websites or redirect users to malicious sites, damaging brand reputation and user trust. The stored nature of the XSS means the malicious payload persists until removed, increasing the window of exposure. Although the plugin is niche, organizations relying on it for embedding Flash content—often legacy systems—may face compliance issues and increased risk of targeted attacks. The absence of patches and known exploits in the wild suggests a window of opportunity for attackers to develop exploits, emphasizing the need for proactive mitigation.

Mitigation Recommendations

1. Immediately audit all web applications using the Top Flash Embed plugin to identify affected versions (<=0.3.4). 2. Disable or remove the Top Flash Embed plugin until a security patch or update is released by the vendor. 3. Implement strict input validation and output encoding on all user-supplied data to prevent injection of malicious scripts. 4. Employ Content Security Policy (CSP) headers to restrict the execution of unauthorized scripts and reduce the impact of XSS attacks. 5. Regularly scan web applications for stored XSS vulnerabilities using automated tools and manual testing. 6. Educate developers and administrators about secure coding practices, especially regarding input sanitization and output encoding. 7. Monitor web server logs and user reports for suspicious activity indicative of exploitation attempts. 8. Once a patch is available from foo123, prioritize timely application of the update and verify remediation through testing. 9. Consider migrating away from Flash-based embedding solutions due to their declining support and inherent security risks.

Pro Console: star threats, build custom feeds, automate alerts via Slack, email & webhooks.Upgrade to Pro

Technical Details

Data Version
5.2
Assigner Short Name
Patchstack
Date Reserved
2025-01-16T11:30:58.639Z
Cvss Version
null
State
PUBLISHED

Threat ID: 69cd723de6bfc5ba1dee8c62

Added to database: 4/1/2026, 7:30:05 PM

Last enriched: 4/1/2026, 8:19:45 PM

Last updated: 4/6/2026, 9:13:50 AM

Views: 3

Community Reviews

0 reviews

Crowdsource mitigation strategies, share intel context, and vote on the most helpful responses. Sign in to add your voice and help keep defenders ahead.

Sort by
Loading community insights…

Want to contribute mitigation steps or threat intel context? Sign in or create an account to join the community discussion.

Actions

PRO

Updates to AI analysis require Pro Console access. Upgrade inside Console → Billing.

Please log in to the Console to use AI analysis features.

Need more coverage?

Upgrade to Pro Console for AI refresh and higher limits.

For incident response and remediation, OffSeq services can help resolve threats faster.

Latest Threats

Breach by OffSeqOFFSEQFRIENDS — 25% OFF

Check if your credentials are on the dark web

Instant breach scanning across billions of leaked records. Free tier available.

Scan now
OffSeq TrainingCredly Certified

Lead Pen Test Professional

Technical5-day eLearningPECB Accredited
View courses