Skip to main content
CVE-2025-2697VulnerabilityPublished

CVE-2025-2697: IBM Cognos Command Center · Open Redirect

Affects IBM Cognos Command CenterSource CVE Database V5

0

Not known to be exploited · CVSS 7.4 High.

Data as of 26 Oct 2026, 06:26 UTC

CVSS 3.1 base score
7.4High
How severe the flaw is on the 0–10 CVSS scale.
EPSS
0.3% chance of exploitation in 30 days – higher than 29% of CVEsExploit Prediction Scoring System: the likelihood attackers will use this flaw soon.
CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:N/I:H/A:N

Exploitation evidence

  1. Disclosed: evidence found.

    CVE published 26 Aug 2025

  2. Detectable: no evidence on record.

    No public nuclei template indexed

  3. Weaponised: no evidence on record.

    No public exploit code indexed in Metasploit or Exploit-DB

  4. Exploited in the wild: no evidence on record.

    Not in CISA KEV and no source reports exploitation

  5. Observed by OffSeq Mirage: no evidence on record.

    No attack traffic recorded by OffSeq Mirage sensors

A missing step is not evidence of safety. Sources: cve.org (opens in a new tab), the Metasploit, Exploit-DB and nuclei-templates index as of 2026-10-26.

What to do

Affected software

ProductAffectedFixed in
IBM Cognos Command CenterAffected
  • =10.2.4.1
  • =10.2.5
Fixed in–

AI-suggested

1. Immediate mitigation should include educating users about the risk of phishing and the importance of verifying URLs before clicking, especially those purporting to come from IBM Cognos Command Center. 2. Implement web filtering and email security solutions that detect and block suspicious URLs and phishing attempts leveraging open redirects. 3. Restrict access to IBM Cognos Command Center interfaces to trusted networks and users via VPN or IP whitelisting to reduce exposure. 4. Monitor logs for unusual redirect patterns or spikes in user redirection events that could indicate exploitation attempts. 5. IBM or third parties should prioritize developing and deploying patches or updates that properly validate redirect parameters to prevent open redirect abuse. 6. Organizations should consider deploying Web Application Firewalls (WAFs) with custom rules to detect and block open redirect attempts targeting the vulnerable parameters. 7. Conduct regular security awareness training emphasizing the risks of open redirects and phishing. 8. Review and harden URL handling and redirection logic in custom integrations with IBM Cognos Command Center if applicable.

Description

IBM Cognos Command Center 10.2.4.1 and 10.2.5 could allow a remote attacker to conduct phishing attacks, using an open redirect attack. By persuading a victim to visit a specially crafted Web site, a remote attacker could exploit this vulnerability to spoof the URL displayed to redirect a user to a malicious Web site that would appear to be trusted. This could allow the attacker to obtain highly sensitive information or conduct further attacks against the victim.

References

Community reviews