CVE-2025-27127: CWE-434: Unrestricted Upload of File with Dangerous Type in Siemens TIA Project-Server
A vulnerability has been identified in TIA Project-Server (All versions < V2.1.1), TIA Project-Server V17 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions), Totally Integrated Automation Portal (TIA Portal) V18 (All versions), Totally Integrated Automation Portal (TIA Portal) V19 (All versions < V19 Update 4), Totally Integrated Automation Portal (TIA Portal) V20 (All versions < V20 Update 3). The affected application improperly handles uploaded projects in the document root. This could allow an attacker with contributor privileges to cause denial of service by uploading a malicious project.
AI Analysis
Technical Summary
CVE-2025-27127 is a medium-severity vulnerability classified under CWE-434, which pertains to the unrestricted upload of files with dangerous types. This vulnerability affects multiple versions of Siemens' Totally Integrated Automation (TIA) Portal and TIA Project-Server products, specifically all versions prior to V2.1.1 of TIA Project-Server, all versions of TIA Project-Server V17, and various versions of TIA Portal from V17 through V20 (up to V20 Update 3). The core issue lies in the improper handling of uploaded project files within the document root directory of the affected applications. An attacker possessing contributor-level privileges can exploit this flaw by uploading a malicious project file that could lead to a denial of service (DoS) condition. The vulnerability does not require user interaction and can be exploited remotely over the network (AV:N), with low attack complexity (AC:L), but requires the attacker to have some level of privileges (PR:L). The impact is limited to availability (A:L) with no direct confidentiality or integrity compromise. The vulnerability has an exploitability rating of 'Proof-of-Concept' (E:P) and a remediation level of official fix available (RL:O), with confirmed report confidence (RC:C). No known exploits are currently reported in the wild. The vulnerability arises from CWE-434, which involves insufficient validation of file types during upload, potentially allowing dangerous files to be placed in sensitive locations, leading to service disruption.
Potential Impact
For European organizations, especially those in industrial automation, manufacturing, and critical infrastructure sectors that rely on Siemens TIA Portal and Project-Server for automation project management, this vulnerability poses a risk of service disruption. A denial of service could halt automation workflows, delay production lines, or interrupt monitoring and control systems, potentially causing operational downtime and financial losses. Although the vulnerability does not directly compromise data confidentiality or integrity, the availability impact can have cascading effects on industrial processes and safety systems. Given Siemens' significant market presence in Europe, particularly in Germany and other industrialized nations, organizations using affected versions without timely patching are at risk. The requirement for contributor privileges limits exploitation to insiders or attackers who have gained some level of access, but this does not eliminate the threat, as insider threats or compromised accounts are common attack vectors. The absence of known exploits in the wild suggests that proactive mitigation can prevent exploitation before widespread attacks occur.
Mitigation Recommendations
European organizations should prioritize upgrading affected Siemens TIA Project-Server and TIA Portal installations to the latest versions that include fixes beyond V2.1.1 for Project-Server and V19 Update 4 or V20 Update 3 for TIA Portal. In the interim, organizations should enforce strict access controls to limit contributor privileges only to trusted personnel and implement monitoring to detect unusual file upload activities. Network segmentation should be applied to isolate TIA Project-Server systems from broader enterprise networks to reduce attack surface. Additionally, validating and restricting file types allowed for upload at the application or network level can help prevent malicious files from being accepted. Regular audits of user permissions and review of uploaded project files can detect potential abuse. Employing application-layer firewalls or intrusion detection systems with signatures for suspicious upload patterns may provide early warnings. Finally, Siemens customers should subscribe to Siemens security advisories to receive timely updates and patches.
Affected Countries
Germany, France, Italy, United Kingdom, Netherlands, Belgium, Sweden, Poland, Czech Republic, Austria
CVE-2025-27127: CWE-434: Unrestricted Upload of File with Dangerous Type in Siemens TIA Project-Server
Description
A vulnerability has been identified in TIA Project-Server (All versions < V2.1.1), TIA Project-Server V17 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions), Totally Integrated Automation Portal (TIA Portal) V18 (All versions), Totally Integrated Automation Portal (TIA Portal) V19 (All versions < V19 Update 4), Totally Integrated Automation Portal (TIA Portal) V20 (All versions < V20 Update 3). The affected application improperly handles uploaded projects in the document root. This could allow an attacker with contributor privileges to cause denial of service by uploading a malicious project.
AI-Powered Analysis
Technical Analysis
CVE-2025-27127 is a medium-severity vulnerability classified under CWE-434, which pertains to the unrestricted upload of files with dangerous types. This vulnerability affects multiple versions of Siemens' Totally Integrated Automation (TIA) Portal and TIA Project-Server products, specifically all versions prior to V2.1.1 of TIA Project-Server, all versions of TIA Project-Server V17, and various versions of TIA Portal from V17 through V20 (up to V20 Update 3). The core issue lies in the improper handling of uploaded project files within the document root directory of the affected applications. An attacker possessing contributor-level privileges can exploit this flaw by uploading a malicious project file that could lead to a denial of service (DoS) condition. The vulnerability does not require user interaction and can be exploited remotely over the network (AV:N), with low attack complexity (AC:L), but requires the attacker to have some level of privileges (PR:L). The impact is limited to availability (A:L) with no direct confidentiality or integrity compromise. The vulnerability has an exploitability rating of 'Proof-of-Concept' (E:P) and a remediation level of official fix available (RL:O), with confirmed report confidence (RC:C). No known exploits are currently reported in the wild. The vulnerability arises from CWE-434, which involves insufficient validation of file types during upload, potentially allowing dangerous files to be placed in sensitive locations, leading to service disruption.
Potential Impact
For European organizations, especially those in industrial automation, manufacturing, and critical infrastructure sectors that rely on Siemens TIA Portal and Project-Server for automation project management, this vulnerability poses a risk of service disruption. A denial of service could halt automation workflows, delay production lines, or interrupt monitoring and control systems, potentially causing operational downtime and financial losses. Although the vulnerability does not directly compromise data confidentiality or integrity, the availability impact can have cascading effects on industrial processes and safety systems. Given Siemens' significant market presence in Europe, particularly in Germany and other industrialized nations, organizations using affected versions without timely patching are at risk. The requirement for contributor privileges limits exploitation to insiders or attackers who have gained some level of access, but this does not eliminate the threat, as insider threats or compromised accounts are common attack vectors. The absence of known exploits in the wild suggests that proactive mitigation can prevent exploitation before widespread attacks occur.
Mitigation Recommendations
European organizations should prioritize upgrading affected Siemens TIA Project-Server and TIA Portal installations to the latest versions that include fixes beyond V2.1.1 for Project-Server and V19 Update 4 or V20 Update 3 for TIA Portal. In the interim, organizations should enforce strict access controls to limit contributor privileges only to trusted personnel and implement monitoring to detect unusual file upload activities. Network segmentation should be applied to isolate TIA Project-Server systems from broader enterprise networks to reduce attack surface. Additionally, validating and restricting file types allowed for upload at the application or network level can help prevent malicious files from being accepted. Regular audits of user permissions and review of uploaded project files can detect potential abuse. Employing application-layer firewalls or intrusion detection systems with signatures for suspicious upload patterns may provide early warnings. Finally, Siemens customers should subscribe to Siemens security advisories to receive timely updates and patches.
For access to advanced analysis and higher rate limits, contact root@offseq.com
Technical Details
- Data Version
- 5.1
- Assigner Short Name
- siemens
- Date Reserved
- 2025-02-19T16:02:09.501Z
- Cvss Version
- 3.1
- State
- PUBLISHED
Threat ID: 686cf5646f40f0eb72f3f5fc
Added to database: 7/8/2025, 10:39:32 AM
Last enriched: 8/13/2025, 12:49:19 AM
Last updated: 8/15/2025, 12:34:51 AM
Views: 11
Related Threats
CVE-2025-9060: CWE-20 Improper Input Validation in MSoft MFlash
CriticalCVE-2025-8675: CWE-918 Server-Side Request Forgery (SSRF) in Drupal AI SEO Link Advisor
MediumCVE-2025-8362: CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') in Drupal GoogleTag Manager
MediumCVE-2025-8361: CWE-962 Missing Authorization in Drupal Config Pages
HighCVE-2025-8092: CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') in Drupal COOKiES Consent Management
HighActions
Updates to AI analysis are available only with a Pro account. Contact root@offseq.com for access.
External Links
Need enhanced features?
Contact root@offseq.com for Pro access with improved analysis and higher rate limits.