CVE-2025-28201: n/a
An issue in Victure RX1800 EN_V1.0.0_r12_110933 allows physically proximate attackers to execute arbitrary code or gain root access.
AI Analysis
Technical Summary
CVE-2025-28201 is a vulnerability identified in the Victure RX1800 device running firmware version EN_V1.0.0_r12_110933. This security flaw allows an attacker with physical proximity to the device to execute arbitrary code or escalate privileges to root level. The vulnerability is classified under CWE-284, which relates to improper access control, indicating that the device fails to adequately restrict access to sensitive functions or code execution paths. The CVSS 3.1 base score is 6.8, reflecting a medium severity level. The attack vector is physical (AV:P), meaning the attacker must be physically near the device to exploit it. The attack complexity is low (AC:L), no privileges are required (PR:N), and no user interaction is needed (UI:N). The impact on confidentiality, integrity, and availability is high (C:H/I:H/A:H), meaning successful exploitation can fully compromise the device. No known exploits are currently in the wild, and no patches have been published yet. The vulnerability likely stems from insufficient authentication or access control mechanisms that allow direct code execution or root access when physical access is obtained. Given the physical proximity requirement, the threat is more relevant in environments where the device is accessible to unauthorized individuals, such as public or semi-public locations.
Potential Impact
For European organizations, the impact of this vulnerability can be significant, especially for those deploying Victure RX1800 devices in sensitive or critical environments. The ability for an attacker to gain root access could lead to full device compromise, allowing interception or manipulation of data, disruption of services, or use of the device as a pivot point for further network intrusion. Sectors such as government, critical infrastructure, healthcare, and enterprises with physical device deployments in accessible locations are particularly at risk. The high impact on confidentiality, integrity, and availability means that sensitive information could be exposed or altered, and operational continuity could be disrupted. Since the attack requires physical proximity, organizations with devices in unsecured or publicly accessible areas face higher risks. The absence of patches increases the urgency for mitigation measures to prevent exploitation.
Mitigation Recommendations
Given the lack of available patches, European organizations should implement strict physical security controls to prevent unauthorized access to the Victure RX1800 devices. This includes securing device locations with locks, surveillance, and access control systems. Network segmentation should be employed to isolate vulnerable devices from critical network segments, limiting potential lateral movement if a device is compromised. Monitoring for unusual device behavior or network traffic can help detect exploitation attempts. Organizations should also consider disabling unnecessary services or interfaces on the device to reduce attack surface. If possible, consult with the vendor for firmware updates or advisories and plan for timely patching once available. Additionally, maintaining an inventory of all deployed Victure RX1800 devices and their physical locations will aid in risk assessment and response planning.
Affected Countries
Germany, France, United Kingdom, Italy, Spain, Netherlands, Poland, Belgium, Sweden, Austria
CVE-2025-28201: n/a
Description
An issue in Victure RX1800 EN_V1.0.0_r12_110933 allows physically proximate attackers to execute arbitrary code or gain root access.
AI-Powered Analysis
Technical Analysis
CVE-2025-28201 is a vulnerability identified in the Victure RX1800 device running firmware version EN_V1.0.0_r12_110933. This security flaw allows an attacker with physical proximity to the device to execute arbitrary code or escalate privileges to root level. The vulnerability is classified under CWE-284, which relates to improper access control, indicating that the device fails to adequately restrict access to sensitive functions or code execution paths. The CVSS 3.1 base score is 6.8, reflecting a medium severity level. The attack vector is physical (AV:P), meaning the attacker must be physically near the device to exploit it. The attack complexity is low (AC:L), no privileges are required (PR:N), and no user interaction is needed (UI:N). The impact on confidentiality, integrity, and availability is high (C:H/I:H/A:H), meaning successful exploitation can fully compromise the device. No known exploits are currently in the wild, and no patches have been published yet. The vulnerability likely stems from insufficient authentication or access control mechanisms that allow direct code execution or root access when physical access is obtained. Given the physical proximity requirement, the threat is more relevant in environments where the device is accessible to unauthorized individuals, such as public or semi-public locations.
Potential Impact
For European organizations, the impact of this vulnerability can be significant, especially for those deploying Victure RX1800 devices in sensitive or critical environments. The ability for an attacker to gain root access could lead to full device compromise, allowing interception or manipulation of data, disruption of services, or use of the device as a pivot point for further network intrusion. Sectors such as government, critical infrastructure, healthcare, and enterprises with physical device deployments in accessible locations are particularly at risk. The high impact on confidentiality, integrity, and availability means that sensitive information could be exposed or altered, and operational continuity could be disrupted. Since the attack requires physical proximity, organizations with devices in unsecured or publicly accessible areas face higher risks. The absence of patches increases the urgency for mitigation measures to prevent exploitation.
Mitigation Recommendations
Given the lack of available patches, European organizations should implement strict physical security controls to prevent unauthorized access to the Victure RX1800 devices. This includes securing device locations with locks, surveillance, and access control systems. Network segmentation should be employed to isolate vulnerable devices from critical network segments, limiting potential lateral movement if a device is compromised. Monitoring for unusual device behavior or network traffic can help detect exploitation attempts. Organizations should also consider disabling unnecessary services or interfaces on the device to reduce attack surface. If possible, consult with the vendor for firmware updates or advisories and plan for timely patching once available. Additionally, maintaining an inventory of all deployed Victure RX1800 devices and their physical locations will aid in risk assessment and response planning.
Technical Details
- Data Version
- 5.1
- Assigner Short Name
- mitre
- Date Reserved
- 2025-03-11T00:00:00.000Z
- Cisa Enriched
- true
- Cvss Version
- 3.1
- State
- PUBLISHED
Threat ID: 682d9816c4522896dcbd6b77
Added to database: 5/21/2025, 9:08:38 AM
Last enriched: 7/12/2025, 3:47:14 AM
Last updated: 1/7/2026, 5:25:02 AM
Views: 49
Community Reviews
0 reviewsCrowdsource mitigation strategies, share intel context, and vote on the most helpful responses. Sign in to add your voice and help keep defenders ahead.
Want to contribute mitigation steps or threat intel context? Sign in or create an account to join the community discussion.
Related Threats
CVE-2026-0650: CWE-306 Missing Authentication for Critical Function in OpenFlagr Flagr
CriticalCVE-2025-15474: CWE-770 Allocation of Resources Without Limits or Throttling in AuntyFey AuntyFey Smart Combination Lock
MediumCVE-2025-14468: CWE-352 Cross-Site Request Forgery (CSRF) in mohammed_kaludi AMP for WP – Accelerated Mobile Pages
MediumCVE-2025-9611: CWE-749 Exposed Dangerous Method or Function in Microsoft Playwright
HighCVE-2026-22162
UnknownActions
Updates to AI analysis require Pro Console access. Upgrade inside Console → Billing.
External Links
Need more coverage?
Upgrade to Pro Console in Console -> Billing for AI refresh and higher limits.
For incident response and remediation, OffSeq services can help resolve threats faster.